The confinement of concrete in compression using CFRP composites - effective design equations

被引:22
作者
Benzaid, Riad [1 ]
Mesbah, Habib-Abdelhak [2 ]
机构
[1] Jijel Univ, LGG, Cite Ouled Issa 18000, Jijel, Algeria
[2] INSA Rennes, LGCGM, F-35708 Rennes 7, France
关键词
strain; CFRP sheets; columns; stress; strengthening; confinement; STRESS-STRAIN MODEL; REINFORCED POLYMER COMPOSITES; HIGH-STRENGTH CONCRETE; RECTANGULAR COLUMNS; FIBER COMPOSITES; FRP COMPOSITES; BEHAVIOR; CYLINDERS; DUCTILITY; SHEETS;
D O I
10.3846/13923730.2013.801911
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of an experimental study on the behaviour of axially loaded short concrete columns, with different cross sections that have been externally strengthened with carbon fibre-reinforced polymer (CFRP) sheets. Six series, forming the total of 60 specimens, were subjected to axial compression. All the test specimens were loaded to failure in axial compression and investigated in both axial and transverse directions. According to the obtained test results, FRP-confined specimen failure occurs before the FRP reached the ultimate strain capacities. Thus, the failure occurs prematurely and the circumferential failure strain is lower than the ultimate strain obtained from the standard tensile testing of the FRP composite. In existing models for FRP-confined concrete, it is commonly assumed that the FRP ruptures when the hoop stress in the FRP jacket reaches its tensile strength from either flat coupon tests, which is herein referred to as the FRP material tensile strength. This phenomenon considerably affects the accuracy of the existing models for FRP-confined concrete. On the basis of the effective lateral confining pressure of the composite jacket and the effective circumferential FRP failure strain, new equations were proposed to predict the strength of FRP-confined concrete and corresponding strain for each of the cross section geometry used, circular and square. The estimations given by these equations were compared with the experimental ones and general conclusions were drawn.
引用
收藏
页码:632 / 648
页数:17
相关论文
共 43 条
[1]   Behavior of normal and high-strength concrete cylinders confined with E-glass/epoxy composite laminates [J].
Almusallam, Tarek H. .
COMPOSITES PART B-ENGINEERING, 2007, 38 (5-6) :629-639
[2]   Analytical models for concrete confined with FRP tubes [J].
Becque, J ;
Patnaik, AK ;
Rizkalla, SH .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2003, 7 (01) :31-38
[3]   FRP-confined Concrete Cylinders: Axial Compression Experiments and Strength Model [J].
Benzaid, Riad ;
Mesbah, Habib ;
Chikh, Nasr Eddine .
JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2010, 29 (16) :2469-2488
[4]  
Benzaid R, 2009, ARAB J SCI ENG, V34, P15
[5]   BEHAVIOUR OF SQUARE CONCRETE COLUMN CONFINED WITH GFRP COMPOSITE WARP [J].
Benzaid, Riad ;
Chikh, Nasr-Eddine ;
Mesbah, Habib .
JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2008, 14 (02) :115-120
[6]   Compressive behavior of concrete externally confined by composite jackets - Part B: modeling [J].
Berthet, JF ;
Ferrier, E ;
Hamelin, P .
CONSTRUCTION AND BUILDING MATERIALS, 2006, 20 (05) :338-347
[7]   Strength and strain enhancements of concrete columns confined with FRP sheets [J].
Campione, G ;
Miraglia, N ;
Papia, M .
STRUCTURAL ENGINEERING AND MECHANICS, 2004, 18 (06) :769-790
[8]  
Chaallal O, 2003, ACI STRUCT J, V100, P215
[9]   STRESS-STRAIN MODEL FOR CONFINED HIGH-STRENGTH CONCRETE [J].
CUSSON, D ;
PAULTRE, P .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1995, 121 (03) :468-477
[10]   Comparative study of models on confinement of concrete cylinders with fiber-reinforced polymer composites [J].
De Lorenzis, L ;
Tepfers, R .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2003, 7 (03) :219-237