Determination of dichloroacetic acid and trichloroacetic acid by liquid-liquid extraction and ion chromatography

被引:13
作者
Ko, YW
Gremm, TJ
Abbt-Braun, G
Frimmel, FH
Chiang, PC
机构
[1] Univ Karlsruhe, Div Water Chem, Engler Bunte Inst, D-76131 Karlsruhe, Germany
[2] Da Yeh Univ, Dept Environm Engn, Changhua 515, Taiwan
[3] Natl Taiwan Univ, Grad Inst Environm Engn, Taipei 106, Taiwan
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2000年 / 366卷 / 03期
关键词
D O I
10.1007/s002160050048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An extraction technique using MTBE (methyl tert. butyl ether) and reagent water in combination with ion chromatography and conductivity determination was developed to quantify dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA) concentrations in raw water after chlorination. The detection limit of the method was 0.45 and 1.50 mu g/L for DCAA and TCAA, respectively. Mean values of recovery ranged from 90 to 96% for DCAA and 95 to 108% for TCAA. The evaluation of recovery and precision of the method indicates that the performance characteristics are comparable with gas chromatographic (GC) methods reported in literature. In addition. the procedure is simple, fast, and does not need any derivatization step. Application of the analytical method to the determination of DCAA and TCAA in real samples is shown.
引用
收藏
页码:244 / 248
页数:5
相关论文
共 19 条
[1]  
*APHA AWWA WEF, 1992, STAND METH EX WAT WA
[2]  
CHIANG PC, 1997, 3 INT WORKSH DRINK W
[3]   IDENTITY AND YIELDS OF MAJOR HALOGENATED PRODUCTS OF AQUATIC FULVIC-ACID CHLORINATION [J].
CHRISTMAN, RF ;
NORWOOD, DL ;
MILLINGTON, DS ;
JOHNSON, JD ;
STEVENS, AA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1983, 17 (10) :625-628
[4]  
Hodgeson J.W., 1992, 5521 EPA
[5]   MONITORING THE EFFLUENTS OF THE TRICHLOROACETIC-ACID PROCESS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HUSAIN, S ;
NARSIMHA, R ;
ALVI, SN ;
RAO, RN .
JOURNAL OF CHROMATOGRAPHY, 1992, 600 (02) :316-319
[6]  
KRASNER SW, 1989, J AM WATER WORKS ASS, V81, P41
[7]   Determination of halogenated acetic acids in chlorinated sea water and drinking water produced offshore [J].
Kristiansen, NK ;
Aune, KT ;
Froshaug, M ;
Becher, G ;
Lundanes, E .
WATER RESEARCH, 1996, 30 (09) :2155-2159
[8]   A one-year survey of halogenated disinfection by-products in the distribution system of treatment plants using three different disinfection processes [J].
LeBel, GL ;
Benoit, FM ;
Williams, DT .
CHEMOSPHERE, 1997, 34 (11) :2301-2317
[9]  
MCCLELLAN JN, 1996, WATER DISINFECTION N
[10]   DETERMINATION OF HALOACETIC ACIDS BY ION CHROMATOGRAPHY [J].
NAIR, LM ;
SAARINORDHAUS, R ;
ANDERSON, JM .
JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) :309-313