Electromagnetic Compatibility Implantable Pacemaker Testing

被引:0
作者
Hajovsky, Radovan [1 ]
Penhaker, Marek [1 ]
Capek, Ondrej [1 ]
Cernohorsky, Jindrich [1 ]
Skapa, Jan [1 ]
Korpas, David [2 ]
机构
[1] VSB Tech Univ Ostrava, Fac Elect Engn & Comp Sci, Dept Measurement & Control, Dept Telecommun, 17 Listopadu 15, Ostrava 70833, Czech Republic
[2] Palacky Univ Olomouc, Fac Med, Krizkovskeho 8, Olomouc 77147, Czech Republic
来源
KNOWLEDGE IN TELECOMMUNICATION TECHNOLOGIES AND OPTICS 2010 (KTTO 2010) | 2010年
关键词
Electromagnetic Compatibility; Implantable Pacemaker; Measurement; Disturbing Signal;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The aim of the work was to assess the influence of electromagnetic non-ionizing radiation to cardiac pacemaker. The electromagnetic field can influence the pacemaker functionality and also the wireless communication between programmer and device. Electromagnetic compatibility is tested by direct induction of interference signal to the inputs of cardiac pacemaker according to technical specification. The tests were also made by generating of interference radio frequency signals to disturb the wireless telemetry communication. For testing purposes a circuit of artificial tissue has been designed and assembled, to which a cardiac pacemaker has been connected, as well as the antenna for short radio distance band. It has been proved that the cardiac pacemaker is resistant to co-phasally fed modulated electromagnetic field and also to the circuit of artificial tissue with the connected cardiac pacemaker. It has also been proved that the wireless telemetry communication is sensitive to the interference and disturbances. The non-proper cardiac pacemaker behavior change can endanger the patient's health during the diagnostics and therapeutics procedure. The results can help the physician in decision of patients with implantable pacemaker to dauntless medical procedure.
引用
收藏
页码:176 / 179
页数:4
相关论文
共 10 条
[1]  
Cerny M., 2010, P 2010 2 INT C COMP, V2NJ
[2]  
Cerny M., 2009, IFMBE P
[3]  
Kalik V., 2003, C P PDS 2003, V2003, P391
[4]   PSYCHOLOGICAL INTOLERANCE TO IMPLANTABLE CARDIOVERTER DEFIBRILLATOR [J].
Korpas, David .
BIOMEDICAL PAPERS-OLOMOUC, 2008, 152 (01) :147-149
[5]  
Krejcar O, 2008, IIT: 2008 INTERNATIONAL CONFERENCE ON INNOVATIONS IN INFORMATION TECHNOLOGY, P656
[6]   COMPLEX BIOMEDICAL SYSTEM WITH BIOTELEMETRIC MONITORING OF LIFE FUNCTIONS [J].
Krejcar, Ondrej ;
Janckulik, Dalibor ;
Motalova, Leona .
EUROCON 2009: INTERNATIONAL IEEE CONFERENCE DEVOTED TO THE 150 ANNIVERSARY OF ALEXANDER S. POPOV, VOLS 1- 4, PROCEEDINGS, 2009, :138-+
[7]   CMOS ISFET-based structures for biomedical applications [J].
Palán, B ;
Roubík, K ;
Husák, M ;
Courtois, B .
1ST ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2000, :502-506
[8]   Analysis of optical-power redistribution for hybrid optical fibers [J].
Skapa, J. ;
Vasinek, V. ;
Siska, P. .
FIBER OPTIC SENSORS AND APPLICATIONS V, 2007, 6770
[9]   Identification of external quantities using redistribution of optical power [J].
Skapa, Jan ;
Siska, Petr ;
Vasinek, Vladimir ;
Vanda, Jan .
OPTICAL SENSORS 2008, 2008, 7003
[10]  
Vasickova Z, 2009, J VIBROENG, V11, P279