Limiting oxygen concentration for extinction of upward spreading flames over inclined thin polyethylene-insulated NiCr electrical wires with opposed-flow under normal- and micro-gravity

被引:41
|
作者
Hu, Longhua [1 ,2 ]
Lu, Yong [1 ]
Yoshioka, Kosuke [2 ]
Zhang, Yangshu [1 ]
Fernandez-Pello, Carlos [3 ]
Chung, Suk Ho [4 ]
Fujita, Osamu [2 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei, Anhui, Peoples R China
[2] Hokkaido Univ, Div Mech & Space Engn, Sapporo, Hokkaido, Japan
[3] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
[4] King Abdullah Univ Sci & Technol, Clean Combust Res Ctr, Thuwal, Saudi Arabia
基金
中国国家自然科学基金;
关键词
Limiting oxygen concentration (LOC); Extinction; Electrical wire; Inclination angle; Microgravity; FIRE SAFETY; IGNITION;
D O I
10.1016/j.proci.2016.09.021
中图分类号
O414.1 [热力学];
学科分类号
摘要
Materials, such as electrical wire, used in spacecraft must pass stringent fire safety standards. Tests for such standards are typically performed under normal gravity conditions and then extended to applications under microgravity conditions. The experiments reported here used polyethylene (PE)-insulated (thickness of 0.15 mm) Nichrome (NiCr)-core (diameter of 0.5 mm) electrical wires. Limiting oxygen concentrations (LOC) at extinction were measured for upward spreading flame at various forced opposed-flow (downward) speeds (0-25 cm/s) at several inclination angles (0-75 degrees) under normal gravity conditions. The differences from those previously obtained under microgravity conditions were quantified and correlated to provide a reference for the development of fire safety test standards for electrical wires to be used in space exploration. It was found that as the opposed-flow speed increased for a specified inclination angle (except the horizontal case), LOC first increased, then decreased and finally increased again. The first local maximum of this LOC variation corresponded to a critical forced flow speed resulted from the change in flame spread pattern from concurrent to counter-current type. This critical forced flow speed correlated well with the buoyancy-induced flow speed component in the wire's direction when the flame base width along the wire was used as a characteristic length scale. LOC was generally higher under the normal gravity than under the microgravity and the difference between the two decreased as the opposed-flow speed increases, following a reasonably linear trend at relatively higher flow speeds (over 10 cm/s). The decrease in the difference in LOC under normal- and microgravity conditions as the opposed-flow speed increases correlated well with the gravity acceleration component in the wire's direction, providing a measure to extend LOC determined by the tests under normal gravity conditions (at various inclination angles and opposed-flow speeds) to LOC under microgravity conditions. (C) 2016 by The Combustion Institute. Published by Elsevier Inc.