A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration

被引:85
作者
Updike, SJ
Shults, MC
Gilligan, BJ
Rhodes, RK
机构
[1] Univ Wisconsin Hosp, Biomed Engn Lab, Dept Med, Hlth Sci Ctr, Madison, WI 53792 USA
[2] Markwell Med Inst, Racine, WI USA
关键词
D O I
10.2337/diacare.23.2.208
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE - To evaluate the lifetime, response time, linearity glucose range, and calibration stability of two different types of continuous glucose sensor implants in a dog model. RESEARCH DESIGN AND METHODS - Glucose sensors based on the enzyme electrode principle that are coupled to a radio transmitter were evaluated on the bench cop, sterilized, and then implanted subcutaneously in nondiabetic mongrel dogs. A multichannel radio receiver and PC data processor were used to record the sensor glucose data. initial early reliable sensor responsivity was recognized by a vigorous hyperglycemic excursion after an intramuscular injection of glucagon. Periodically the dogs were made temporarily diabetic by blocking pancreatic insulin secretion by subcutaneous injection of a synthetic somatostatin (octreotide). By using exogenous insulin injection followed by intravenous glucose infusion, glucose levels were manipulated through the entire clinical range of interest: 2.2-38.9 mmol/l (40-700 mg/dl). Every 5-10 min, reference blood glucose samples were obtained and run ill our hospital clinical laboratory. The glucose sensor data was evaluated by linear least squares optimization and by the error grid method. RESULTS- Beginning as early as postimplant day 7, the in vivo performances of sensors were evaluated by using glucose infusion studies per formed every 1-4 weeks, Bench-top and in vivo 90% response-time sensors were in the range of 4-7 min during sensor lifetime. Best-performing sensors from both types are summarized as follows. The earlier-stage technology was less linear with a dynamic range of no more than 22 mmol/l glucose, had a best-case recalibration interval of 18 days, and had a maximum lifetime of 94 days. The improved later-stage technology sensors, which were constructed with the addition of bioprotective and angiogenic membranes, were linear over the full extended range of clinical interest (2.2-38.9 mmol/l [40-700 mg/dl glucose]), had a best-case recalibration interval of 20 days, and had a maximum lifetime of >160 days. CONCLUSIONS - Stable clinically useful sensor performance was demonstrated as early as 7 days alter implantation and for a sensor lifetime of 3-5 months. This type of subcutaneous glucose sensor appears to be promising as a continuous and painless long-term method for monitoring blood glucose. Specifically sensors with top-layer materials that stimulate angiogenesis at the sensor/tissue interface may have better dynamic measurement range, longer lifetimes, and better calibration stability than our previously reported sensors.
引用
收藏
页码:208 / 214
页数:7
相关论文
共 14 条
  • [1] DYNAMIC CONCENTRATION CHALLENGES FOR BIOSENSOR CHARACTERIZATION
    BAKER, DA
    GOUGH, DA
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (9-10) : 433 - 441
  • [2] EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE
    CLARKE, WL
    COX, D
    GONDERFREDERICK, LA
    CARTER, W
    POHL, SL
    [J]. DIABETES CARE, 1987, 10 (05) : 622 - 628
  • [3] GASKILL G, 1995, 1004DOC0868 SEIKO TE
  • [4] Performance of subcutaneously implanted glucose sensors: A review
    Gerritsen, M
    Jansen, JA
    Kros, A
    Nolte, RJM
    Lutterman, JA
    [J]. JOURNAL OF INVESTIGATIVE SURGERY, 1998, 11 (03) : 163 - 174
  • [5] EVALUATION OF A SUBCUTANEOUS GLUCOSE SENSOR OUT TO 3 MONTHS IN A DOG-MODEL
    GILLIGAN, BJ
    SHULTS, MC
    RHODES, RK
    UPDIKE, SJ
    [J]. DIABETES CARE, 1994, 17 (08) : 882 - 887
  • [6] PREDICTION OF POCKET-PORTABLE AND IMPLANTABLE GLUCOSE ENZYME ELECTRODE PERFORMANCE FROM COMBINED SPECIES PERMEABILITY AND DIGITAL-SIMULATION ANALYSIS
    RHODES, RK
    SHULTS, MC
    UPDIKE, SJ
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (09) : 1520 - 1529
  • [7] THE EFFECT OF INTENSIVE TREATMENT OF DIABETES ON THE DEVELOPMENT AND PROGRESSION OF LONG-TERM COMPLICATIONS IN INSULIN-DEPENDENT DIABETES-MELLITUS
    SHAMOON, H
    DUFFY, H
    FLEISCHER, N
    ENGEL, S
    SAENGER, P
    STRELZYN, M
    LITWAK, M
    WYLIEROSETT, J
    FARKASH, A
    GEIGER, D
    ENGEL, H
    FLEISCHMAN, J
    POMPI, D
    GINSBERG, N
    GLOVER, M
    BRISMAN, M
    WALKER, E
    THOMASHUNIS, A
    GONZALEZ, J
    GENUTH, S
    BROWN, E
    DAHMS, W
    PUGSLEY, P
    MAYER, L
    KERR, D
    LANDAU, B
    SINGERMAN, L
    RICE, T
    NOVAK, M
    SMITHBREWER, S
    MCCONNELL, J
    DROTAR, D
    WOODS, D
    KATIRGI, B
    LITVENE, M
    BROWN, C
    LUSK, M
    CAMPBELL, R
    LACKAYE, M
    RICHARDSON, M
    LEVY, B
    CHANG, S
    HEINHEINEMANN, M
    BARRON, S
    ASTOR, L
    LEBECK, D
    BRILLON, D
    DIAMOND, B
    VASILASDWOSKIN, A
    LAURENZI, B
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (14) : 977 - 986
  • [8] A TELEMETRY-INSTRUMENTATION SYSTEM FOR MONITORING MULTIPLE SUBCUTANEOUSLY IMPLANTED GLUCOSE SENSORS
    SHULTS, MC
    RHODES, RK
    UPDIKE, SJ
    GILLIGAN, BJ
    REINING, WN
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (10) : 937 - 942
  • [9] Stokes K B, 1988, J Biomater Appl, V3, P228, DOI 10.1177/088532828800300205
  • [10] Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)
    Turner, RC
    Holman, RR
    Cull, CA
    Stratton, IM
    Matthews, DR
    Frighi, V
    Manley, SE
    Neil, A
    McElroy, K
    Wright, D
    Kohner, E
    Fox, C
    Hadden, D
    Mehta, Z
    Smith, A
    Nugent, Z
    Peto, R
    Adlel, AI
    Mann, JI
    Bassett, PA
    Oakes, SF
    Dornan, TL
    Aldington, S
    Lipinski, H
    Collum, R
    Harrison, K
    MacIntyre, C
    Skinner, S
    Mortemore, A
    Nelson, D
    Cockley, S
    Levien, S
    Bodsworth, L
    Willox, R
    Biggs, T
    Dove, S
    Beattie, E
    Gradwell, M
    Staples, S
    Lam, R
    Taylor, F
    Leung, L
    Carter, RD
    Brownlee, SM
    Fisher, KE
    Islam, K
    Jelfs, R
    Williams, PA
    Williams, FA
    Sutton, PJ
    [J]. LANCET, 1998, 352 (9131) : 837 - 853