Properties and in vitro evaluation of high modulus biodegradable polyurethanes for applications in cardiovascular stents

被引:16
作者
Sgarioto, Melissa [1 ,2 ]
Adhikari, Raju [3 ]
Gunatillake, Pathiraja A. [3 ]
Moore, Tim [4 ]
Malherbe, Francois [1 ]
Nagel, Marie-Danielle [2 ]
Patterson, John [1 ]
机构
[1] Swinburne Univ Technol, Fac Life & Social Sci, Hawthorn, Vic 3122, Australia
[2] Univ Technol Compiegne, CNRS, UMR Biomecan & Bioingn 7338, Ctr Rech Royallieu, Compiegne, France
[3] CSIRO Mat Sci & Engn, Clayton, Vic 3169, Australia
[4] PolyNovo Biomat Pty Ltd, Port Melbourne, Vic 3207, Australia
关键词
polyurethane; properties; degradation; cardiovascular stents; sterilisation; GAMMA-IRRADIATION; MICROSPHERES; FLOW;
D O I
10.1002/jbm.b.33137
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study examined the suitability of a family of biodegradable polyurethanes (PUs) NovoSorb (TM) developed for the vascular stent application. These segmented PUs are formulated to be biodegradable using degradable polyester and PU blocks. A series of PUs comprising different hard segment weight percentage ranging from 60 to 100 were investigated. The mechanical properties of the PUs were evaluated before and after gamma sterilization to assess their suitability for vascular implants. The real-time (PBS/37 degrees C/pH 7.4) hydrolytic degradation studies were carried out under sterile conditions and PU glass transition temperature, molecular weight, and mass loss at 3, 6, and 9 months were determined. The viability and growth of Human Umbilical Vein Endothelial Cells (HUVEC) on PU surfaces were determined to assess the effect of PU degradation. The effect of coating of extracellular matrix (ECM) components on cell viability was also investigated. The study showed that the PUs possess excellent mechanical properties exhibiting high tensile strength (41-56 MPa) and tensile modulus (897-1496 MPa). The PU films maintained mechanical strength during the early phase of the degradation but lost strength at latter stages. The unmodified polymer surface of each PU promotes endothelial cell growth and proliferation, with a HUVEC retention rate of >70%. (C) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1711 / 1719
页数:9
相关论文
共 21 条
  • [1] Tetracycline-HCl-loaded poly(DL-lactide-co-glycolide) microspheres prepared by a spray drying technique:: influence of γ-irradiation on radical formation and polymer degradation
    Bittner, B
    Mäder, K
    Kroll, C
    Borchert, HH
    Kissel, T
    [J]. JOURNAL OF CONTROLLED RELEASE, 1999, 59 (01) : 23 - 32
  • [2] Bioresorbable polymeric stents: current status and future promise
    Eberhart, RC
    Su, SH
    Nguyen, KT
    Zilberman, M
    Tang, LP
    Nelson, KD
    Frenkel, P
    [J]. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2003, 14 (04) : 299 - 312
  • [3] Attachment, morphology and adherence of human endothelial cells to vascular prosthesis materials under the action of shear stress
    Feugier, P
    Black, RA
    Hunt, JA
    How, TV
    [J]. BIOMATERIALS, 2005, 26 (13) : 1457 - 1466
  • [4] Freitas R.A., 2003, NANOMEDICINE BIOCOMP
  • [5] Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
    Heublein, B
    Rohde, R
    Kaese, V
    Niemeyer, M
    Hartung, W
    Haverich, A
    [J]. HEART, 2003, 89 (06) : 651 - 656
  • [6] Human macrophage-mediated biodegradation of polyurethanes: assessment of candidate enzyme activities
    Labow, RS
    Meek, E
    Matheson, LA
    Santerre, JP
    [J]. BIOMATERIALS, 2002, 23 (19) : 3969 - 3975
  • [7] Coronary stents: A materials perspective
    Mani, Gopinath
    Feldman, Marc D.
    Patel, Devang
    Agrawal, C. Mauli
    [J]. BIOMATERIALS, 2007, 28 (09) : 1689 - 1710
  • [8] Gamma irradiation effects on poly(DL-lactictide-co-glycolide) microspheres
    Montanari, L
    Costantini, M
    Signoretti, EC
    Valvo, L
    Santucci, M
    Bartolomei, M
    Fattibene, P
    Onori, S
    Faucitano, A
    Conti, B
    Genta, I
    [J]. JOURNAL OF CONTROLLED RELEASE, 1998, 56 (1-3) : 219 - 229
  • [9] Moore TR, High modulus polyurethane and polyurethane/urea composition, Patent No. [US20090099600A1, 20090099600]
  • [10] Flow characteristics past jellyfish and St. Vincent valves in the aortic position under physiological pulsatile flow conditions
    Morsi, YS
    Sakhaeimanesh, AA
    [J]. ARTIFICIAL ORGANS, 2000, 24 (07) : 564 - 574