A treatment planning and delivery comparison of volumetric modulated arc therapy with or without flattening filter for gliomas, brain metastases, prostate, head/neck and early stage lung cancer

被引:34
作者
Gasic, Daniel [1 ]
Ohlhues, Lars [1 ]
Brodin, N. Patrik [2 ]
Fog, Lotte S. [1 ]
Pommer, Tobias [1 ,3 ]
Bangsgaard, Jens P. [1 ]
Rosenschold, Per Munck A. F. [1 ,3 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Oncol, Sect Radiotherapy, Copenhagen, Denmark
[2] Albert Einstein Coll Med, Inst Oncophys, Bronx, NY 10461 USA
[3] Univ Copenhagen, Niels Bohr Inst, DK-2100 Copenhagen, Denmark
关键词
STEREOTACTIC BODY RADIOTHERAPY; FREE BEAMS; PHOTON BEAMS; IMRT; SBRT; FEASIBILITY; VMAT; PATIENT;
D O I
10.3109/0284186X.2014.925578
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Flattening filter-free (FFF) beams are an emerging technology that has not yet been widely implemented as standard practice in radiotherapy centers. To facilitate the clinical implementation of FFF, we attempted to elucidate the difference in plan quality and treatment delivery time compared to flattening filter beams (i.e. standard, STD) for several patient groups. We hypothesize that the treatment plan quality is comparable while the treatment delivery time of volumetric modulated arc therapy (VMAT) is considerably shorter using FFF beams, especially for stereotactic treatments. Methods. A total of 120 patients treated for head and neck (H&N) tumors, high-grade glioma, prostate cancer, early stage lung cancer and intra-cranial metastatic disease (both single and multiple metastases) were included in the study. For each cohort, 20 consecutive patients were selected. The plans were generated using STD-and FFF-VMAT for both 6 MV and 10 MV, and were compared with respect to plan quality, monitor units and delivery time using Wilcoxon signed rank tests. Results. For H&N and high-grade gliomas, there was a significant difference in homogeneity index in favor for STD-VMAT (p < 0.001). For the stereotactic sites there were no differences in plan conformity. Stereotactic FFF-VMAT plans required significantly shorter delivery time compared to STD-VMAT plans (p < 0.001) for higher dose per fraction, on average 54.5% for 6 MV and 71.4% for 10 MV. FFF-VMAT generally required a higher number of MU/Gy (p < 0.001), on average 7.0% for 6 MV and 8.4% for 10 MV. Conclusion. It was generally possible to produce FFF-VMAT plans with the same target dose coverage and doses to organs at risk as STD-VMAT plans. Target dose homogeneity tended to be somewhat inferior for FFF-VMAT for the larger targets investigated. For stereotactic radiotherapy, FFF-VMAT resulted in a considerable time gain while maintaining similar plan quality compared to STD beams.
引用
收藏
页码:1005 / 1011
页数:7
相关论文
共 25 条
[1]   Linac based SBRT for prostate cancer in 5 fractions with VMAT and flattening filter free beams: preliminary report of a phase II study [J].
Alongi, Filippo ;
Cozzi, Luca ;
Arcangeli, Stefano ;
Iftode, Cristina ;
Comito, Tiziana ;
Villa, Elisa ;
Lobefalo, Francesca ;
Navarria, Pierina ;
Reggiori, Giacomo ;
Mancosu, Pietro ;
Clerici, Elena ;
Fogliata, Antonella ;
Tomatis, Stefano ;
Taverna, Gianluigi ;
Graziotti, Pierpaolo ;
Scorsetti, Marta .
RADIATION ONCOLOGY, 2013, 8
[2]   Rotational radiotherapy for prostate cancer in clinical practice [J].
Aznar, Marianne C. ;
Petersen, Peter Meidahl ;
Logadottir, Ashildur ;
Lindberg, Henriette ;
Korreman, Stine S. ;
Kjaer-Kristoffersen, Flemming ;
Engelholm, Svend Aage .
RADIOTHERAPY AND ONCOLOGY, 2010, 97 (03) :480-484
[3]   COMMISSIONING OF VOLUMETRIC MODULATED ARC THERAPY (VMAT) [J].
Bedford, James L. ;
Warrington, Alan P. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (02) :537-545
[4]   LOWERING WHOLE-BODY RADIATION DOSES IN PEDIATRIC INTENSITY-MODULATED RADIOTHERAPY THROUGH THE USE OF UNFLATTENED PHOTON BEAMS [J].
Cashmore, Jason ;
Ramtohul, Mark ;
Ford, Dan .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (04) :1220-1227
[5]   Volumetric-modulated arc radiotherapy for carcinomas of the anal canal: A treatment planning comparison with fixed field IMRT [J].
Clivio, Alessandro ;
Fogliata, Antonella ;
Franzetti-Pellanda, Alessandra ;
Nicolini, Giorgia ;
Vanetti, Eugenio ;
Wyttenbach, Rolf ;
Cozzi, Luca .
RADIOTHERAPY AND ONCOLOGY, 2009, 92 (01) :118-124
[6]   A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy [J].
Cozzi, Luca ;
Dinshaw, Ketayun Ardeshir ;
Shrivastava, Shyam Kishore ;
Mahantshetty, Umesh ;
Engineer, Reena ;
Deshpande, Deepak Dattatray ;
Jamema, S. V. ;
Vanetti, Eugenio ;
Clivio, Alessandro ;
Nicolini, Giorgia ;
Fogliata, Antonella .
RADIOTHERAPY AND ONCOLOGY, 2008, 89 (02) :180-191
[7]   Current status and future perspective of flattening filter free photon beams [J].
Georg, Dietmar ;
Knoos, Tommy ;
McClean, Brendan .
MEDICAL PHYSICS, 2011, 38 (03) :1280-1293
[8]   Commissioning of the Varian TrueBeam linear accelerator: A multi-institutional study [J].
Glide-Hurst, C. ;
Bellon, M. ;
Foster, R. ;
Altunbas, C. ;
Speiser, M. ;
Altman, M. ;
Westerly, D. ;
Wen, N. ;
Zhao, B. ;
Miften, M. ;
Chetty, I. J. ;
Solberg, T. .
MEDICAL PHYSICS, 2013, 40 (03)
[9]   Time dependence of intrafraction patient motion assessed by repeat stereoscopic imaging [J].
Hoogeman, Mischa S. ;
Nuyttens, Joost J. ;
Levendag, Peter C. ;
Heumen, Ben J. M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (02) :609-618
[10]   Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer [J].
Hrbacek, Jan ;
Lang, Stephanie ;
Graydon, Shaun N. ;
Kloeck, Stephan ;
Riesterer, Oliver .
MEDICAL PHYSICS, 2014, 41 (03)