Comparison of optimal performance at 300 keV of three direct electron detectors for use in low dose electron microscopy

被引:237
作者
McMullan, G. [1 ]
Faruqi, A. R. [1 ]
Clare, D. [2 ,3 ]
Henderson, R. [1 ]
机构
[1] MRC, Mol Biol Lab, Cambridge CB2 0QH, England
[2] Univ London, Birkbeck Coll, London WC1E 7HX, England
[3] Univ London, Birkbeck Coll, Inst Struct & Mol Biol, London WC1E 7HX, England
基金
英国医学研究理事会; 英国惠康基金;
关键词
DQE; MTF; CMOS; NOISE TRANSFER; CCD CAMERAS; CRYO-EM; SIGNAL;
D O I
10.1016/j.ultramic.2014.08.002
中图分类号
TH742 [显微镜];
学科分类号
摘要
Low dose electron imaging applications such as electron cryo-microscopy are now benefit:Ling from the improved performance and flexibility of recently introduced electron imaging detectors in which electrons are directly incident on backthinned CMOS sensors. There are currently three commercially available detectors of this type: the Direct Electron DE-20, the FEI Falcon II and the Gatan K2 Summit. These have different characteristics and so it is important to compare their imaging properties carefully with a view to optimise how each is used. Results at 300 keV for both the modulation transfer function (MTF) and the detective quantum efficiency (DQE) are presented. Of these, the DQE is the most important in the study of radiation sensitive samples where detector performance is crucial. We find that all three defectors have a better DQE than film. The K2 Summit has the best DQE at low spatial frequencies but with increasing spatial frequency its DQE falls below that of the Falcon II. (C) 2014 The Authors. Published by Elsevier B.V.
引用
收藏
页码:156 / 163
页数:8
相关论文
共 16 条
[1]   Comparison of approaches and artefacts in the measurement of detector modulation transfer functions [J].
Boothroyd, C. B. ;
Kasama, T. ;
Dunin-Borkowski, R. E. .
ULTRAMICROSCOPY, 2013, 129 :18-29
[2]  
Dainty J.C., 1974, IMAGE SCI
[3]  
Faruqi A.R., 2005, NUCL INSTRUM METHODS, V11, P2001
[4]  
Landau L, 1944, J PHYS-USSR, V8, P201
[5]   Influence of electron dose rate on electron counting images recorded with the K2 camera [J].
Li, Xueming ;
Zheng, Shawn Q. ;
Egami, Kiyoshi ;
Agard, David A. ;
Cheng, Yifan .
JOURNAL OF STRUCTURAL BIOLOGY, 2013, 184 (02) :251-260
[6]   Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM [J].
Li, Xueming ;
Mooney, Paul ;
Zheng, Shawn ;
Booth, Christopher R. ;
Braunfeld, Michael B. ;
Gubbens, Sander ;
Agard, David A. ;
Cheng, Yifan .
NATURE METHODS, 2013, 10 (06) :584-+
[7]   Electron imaging with Medipix2 hybrid pixel detector [J].
McMullan, G. ;
Cattermole, D. M. ;
Chen, S. ;
Henderson, R. ;
Llopart, X. ;
Summerfield, C. ;
Tlustos, L. ;
Faruqi, A. R. .
ULTRAMICROSCOPY, 2007, 107 (4-5) :401-413
[8]   Single event imaging for electron microscopy using MAPS detectors [J].
McMullan, G. ;
Turchetta, R. ;
Faruqi, A. R. .
JOURNAL OF INSTRUMENTATION, 2011, 6
[9]   Enhanced imaging in low dose electron microscopy using electron counting [J].
McMullan, G. ;
Clark, A. T. ;
Turchetta, R. ;
Faruqi, A. R. .
ULTRAMICROSCOPY, 2009, 109 (12) :1411-1416
[10]   Detective quantum efficiency of electron area detectors in electron microscopy [J].
McMullan, G. ;
Chen, S. ;
Henderson, R. ;
Faruqi, A. R. .
ULTRAMICROSCOPY, 2009, 109 (09) :1126-1143