MASTER: a Windows program for recording multiple auditory steady-state responses

被引:150
|
作者
John, MS [1 ]
Picton, TW [1 ]
机构
[1] Baycrest Ctr Geriatr Care, Rotman Res Inst, Toronto, ON M6A 2E1, Canada
基金
英国医学研究理事会;
关键词
auditory evoked potentials; frequency analysis; objective audiometry; steady-state responses;
D O I
10.1016/S0169-2607(99)00035-8
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
MASTER is a Windows-based data acquisition system designed to assess human hearing by recording auditory steady-state responses. The system simultaneously generates multiple amplitude-modulated and/or frequency-modulated auditory stimuli, acquires electrophysiological responses to these stimuli, displays these responses in the frequency-domain, and determines whether or not the responses are significantly larger than background electroencephalographic activity. The operator can print out the results, store the data on disk for more extensive analysis by other programs, review stored data, and combine results. The system design follows clear principles concerning the generation of acoustic signals, the acquisition of artifact-free data, the analysis of electrophysiological responses in the frequency-domain, and the objective detection of signals in noise. The instrument uses a popular programming language (LabVIEW) and a commercial data acquisition board (AT-MIO-16E-10), both of which are available from National Instruments. (C) 2000 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:125 / 150
页数:26
相关论文
共 50 条
  • [1] Multiple auditory steady-state responses (MASTER): Stimulus and recording parameters
    John, MS
    Lins, OG
    Boucher, BL
    Picton, TW
    AUDIOLOGY, 1998, 37 (02): : 59 - 82
  • [2] Multiple auditory steady-state responses
    Picton, TW
    Dimitrijevic, A
    John, MS
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2002, 111 (05) : 16 - 21
  • [3] Comparison of MASTER and AUDERA for measurement of auditory steady-state responses
    Luts, H
    Wouters, J
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2005, 44 (04) : 244 - 253
  • [4] Hearing assessment by recording multiple auditory steady-state responses: the influence of test duration
    Luts, H
    Wouters, J
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2004, 43 (08) : 471 - 478
  • [5] The use of phase in the detection of auditory steady-state responses
    Picton, TW
    Dimitrijevic, A
    John, MS
    Van Roon, P
    CLINICAL NEUROPHYSIOLOGY, 2001, 112 (09) : 1698 - 1711
  • [6] Auditory Steady-State Responses
    Korczak, Peggy
    Smart, Jennifer
    Delgado, Rafael
    Strobel, Theresa M.
    Bradford, Christina
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2012, 23 (03) : 146 - 170
  • [7] Multiple auditory steady-state responses to AM and FM stimuli
    John, MS
    Dimitrijevic, A
    van Roon, P
    Picton, TW
    AUDIOLOGY AND NEURO-OTOLOGY, 2001, 6 (01) : 12 - 27
  • [8] Intracerebral sources of human auditory steady-state responses
    Herdman, AT
    Lins, O
    Van Roon, P
    Stapells, DR
    Scherg, M
    Picton, TW
    BRAIN TOPOGRAPHY, 2002, 15 (02) : 69 - 86
  • [9] On the terminology of auditory steady-state responses. What differentiates steady-state and transient potentials?
    Muehler, R.
    HNO, 2012, 60 (05) : 421 - 426
  • [10] Intracerebral Sources of Human Auditory Steady-State Responses
    Anthony T. Herdman
    Otavio Lins
    Patricia Van Roon
    David R. Stapells
    Michael Scherg
    Terence W. Picton
    Brain Topography, 2002, 15 : 69 - 86