Evaluation of neovascularization with spectral computed tomography in a rabbit VX2 liver model: a comparison with real-time contrast-enhanced ultrasound and molecular biological findings

被引:6
|
作者
Zhou, Yue [1 ]
Gao, Jian-Bo [1 ]
Xu, Han [2 ]
Dong, Jun-Qiang [1 ]
Wang, Ming-Yue [1 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Radiol, Zhengzhou 450052, Peoples R China
[2] Zhengzhou Univ, Affiliated Hosp 1, Dept Breast Surg, Zhengzhou 450052, Peoples R China
关键词
ENDOTHELIAL GROWTH-FACTOR; HEPATOCELLULAR-CARCINOMA; PERFUSION CT; TUMOR; ANGIOGENESIS; MECHANISMS;
D O I
10.1259/bjr.20140548
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To validate the feasibility of using the parameters of spectral CT and CT perfusion and the dynamic features of real-time contrast-enhanced ultrasound (CEUS) to evaluate the vascularization of VX2 hepatic tumours. Methods: Spectral CT imaging, CT perfusion and CEUS analysis were performed on rabbits implanted with VX2 hepatic tumours, 7 and 14 days after implantation. The perfusion parameters of CT, normalized iodine concentration (NIC) and dynamic features of CEUS were measured in the rim of the tumour (TR) and the normal liver region. The expression of vascular endothelial growth factor (VEGF) and fibroblast growth factor 2 (FGF2) was also determined. Results: Increased perfusion parameters of CT were found in the TR. In addition, the NIC was elevated in TR during the arterial phase, and the peak intensity of the CEUS of the TR was reached significantly earlier than that on normal liver region. At 14 days, the perfusion parameters of CT (blood volume, permeability surface and hepatic arterial fraction) offered higher accuracy and stability in differentiating the TR from the normal liver region. Furthermore, CEUS was more accurate in diagnosing tumours < 1.0 cm in diameter. In addition, VEGF and FGF2 expression was higher in the TR and were positively correlated with CT and CEUS parameters, except mean transit time, rise time, washout time and peak time. Conclusion: Use of spectral CT with perfusion techniques, iodine-based material-decomposition analysis and dynamic CEUS changes may reflect the angiogenesis and haemodynamic information of hepatic tumours. Advances in knowledge: It is feasible to assess vascularization in hepatic cancer using CT or CEUS.
引用
收藏
页数:13
相关论文
共 32 条
  • [1] Enhancement pattern of hepatocellular carcinoma: comparison of real-time contrast-enhanced ultrasound and contrast-enhanced computed tomography
    Liu, Guang-Jian
    Xu, Hui-Xiong
    Lu, Ming-De
    Xie, Xiao-Yan
    Xu, Zuo-Feng
    Zheng, Yan-Ling
    Liang, Jin-Yu
    CLINICAL IMAGING, 2006, 30 (05) : 315 - 321
  • [2] Novel fluorescence nanobubbles for contrast-enhanced ultrasound imaging in rabbit VX2 hepatocellular carcinoma model
    Yu Houqiang
    Wang Wei
    He Xiaoling
    Zhou Qibing
    Ding Mingyue
    MEDICAL IMAGING 2017: ULTRASONIC IMAGING AND TOMOGRAPHY, 2017, 10139
  • [3] Contrast-enhanced ultrasonography of the rabbit VX2 tumor model: Analysis of vascular pathology
    Liu, Yanjun
    Ren, Weidong
    Liu, Caigang
    Huang, Kun
    Feng, Yueqin
    Wang, Xuemei
    Tong, Yuzhang
    ONCOLOGY LETTERS, 2012, 4 (04) : 685 - 690
  • [4] Correlation between Contrast-Enhanced Ultrasound and Microvessel Density via CD31 and CD34 in the rabbit VX2 lung peripheral tumor model
    Xing, Jin
    He, Wen
    Ding, Yi-Wen
    Li, Yang
    Li, Yan-Dong
    MEDICAL ULTRASONOGRAPHY, 2018, 20 (01) : 37 - 42
  • [5] Monochromatic Spectral Computed Tomography with Low Iodine Concentration Contrast Medium in a Rabbit VX2 Liver Model: Investigation of Image Quality and Detection Rate
    Zhou, Yue
    Xu, Han
    Hou, Ping
    Dong, Jun Q.
    Wang, Ming Y.
    Gao, Jian B.
    ACADEMIC RADIOLOGY, 2016, 23 (04) : 486 - 495
  • [6] Spiral computed tomography evaluation of rabbit VX2 hepatic tumors treated with 20 kHz ultrasound and microbubbles
    Shen, Zhi-Yong
    Liu, Chun
    Wu, Ming-Feng
    Shi, Hai-Feng
    Zhou, Yu-Feng
    Zhuang, Wei
    Xia, Gan-Lin
    ONCOLOGY LETTERS, 2017, 14 (03) : 3124 - 3130
  • [7] Early Identification of Residual Tumors following Microwave Ablation Using Contrast-Enhanced Ultrasonography in a Rabbit VX2 Liver Cancer Model
    Yi, Huiming
    Cai, Baohuan
    Ai, Xi
    Li, Kaiyan
    Song, Pengfei
    Zhang, Wei
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [8] Contrast-Enhanced Ultrasound for the Characterization of Incidental Liver Lesions - An Economical Evaluation in Comparison with Multi-Phase Computed Tomography
    Giesel, F. L.
    Delorme, S.
    Sibbel, R.
    Kauczor, H. -U.
    Krix, M.
    ULTRASCHALL IN DER MEDIZIN, 2009, 30 (03): : 259 - 268
  • [9] Dynamic Contrast-Enhanced Magnetic Resonance Imaging Evaluation of VX2 Carcinoma in a Rabbit Model Comparison of 1.0-M Gadobutrol and 0.5-M Gadopentetate Dimeglumine
    Chang, Jung Min
    Moon, Woo Kyung
    Cha, Joo Hee
    Jung, Eun-Jung
    Cho, Nariya
    Kim, Seung Ja
    INVESTIGATIVE RADIOLOGY, 2010, 45 (10) : 655 - 661
  • [10] Usefulness of real-time contrast-enhanced ultrasound guided coaxial needle biopsy for focal liver lesions
    Cao, Xiaojing
    Liu, Zhenxing
    Zhou, Xiang
    Geng, Chengyun
    Chang, Qing
    Zhu, Li
    Feng, Wenqi
    Xu, Tianyu
    Xin, Yujing
    ABDOMINAL RADIOLOGY, 2019, 44 (01) : 310 - 317