Electrochemical reduction of metronidazole at a DNA-modified glassy carbon electrode

被引:51
|
作者
Brett, AMO [1 ]
Serrano, SHP [1 ]
Gutz, I [1 ]
LaScalea, MA [1 ]
机构
[1] UNIV SAO PAULO,INST QUIM,BR-05599970 SAO PAULO,BRAZIL
来源
BIOELECTROCHEMISTRY AND BIOENERGETICS | 1997年 / 42卷 / 02期
关键词
differential pulse voltammetry; cyclic voltammetry; nitroimidazole; DNA-modified electrode; glassy carbon;
D O I
10.1016/S0302-4598(96)05122-7
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The electrochemical reduction of metronidazole was investigated using, for the first time, the newly developed DNA-modified glassy carbon electrode. The results are compared with reduction at bare glassy carbon electrodes. The potentials for reduction were less negative when using the DNA-modified glassy carbon electrode although the mechanism was the same. A potential-pH dependence of one electron per proton was observed in acid media whereas for neutral and alkaline solution no dependence was found. The DNA-modified glassy carbon electrode enables preconcentration of the sample for chosen times on the electrode surface which is convenient for analytical applications. The limit of detection using the DNA-modified glassy carbon electrode at pH 4.5 with 2 min preconcentration is 1.67 mu M, and without preconcentration it is three times higher, 3.25 mu M At a bare glassy carbon electrode, where preconcentration is not possible, the limit of detection for the same pH is 3.44 mu M. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:175 / 178
页数:4
相关论文
共 50 条
  • [31] Electrochemical corrosion of a glassy carbon electrode
    Yi, Youngmi
    Weinberg, Gisela
    Prenzel, Marina
    Greiner, Mark
    Heumann, Saskia
    Becker, Sylvia
    Schloegl, Robert
    CATALYSIS TODAY, 2017, 295 : 32 - 40
  • [32] Electrochemical reduction of SO2 on poly-Co-3-tetraaminophenylporphyrin glassy carbon modified electrode
    Fuenzalida, Francesca
    Dreyse, Paulina
    Villagra, Diego
    Matsuhiro, Betty
    Mendoza, Leonora
    Aguirre, Maria J.
    Isaacs, Mauricio
    JOURNAL OF COORDINATION CHEMISTRY, 2009, 62 (01) : 130 - 140
  • [33] Electrochemical study of niclosamide at poly(3,4-ethylenedioxythiophene) modified glassy carbon electrode
    Mehretie, Solomon
    Admassie, Shimelis
    Tessema, Merid
    Solomon, Theodros
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 168 : 97 - 102
  • [34] The electrochemical behavior of hemoglobin on SWNTs/DDAB film modified glassy carbon electrode
    Yang, PL
    Zhao, Q
    Gu, ZN
    Zhuang, QK
    ELECTROANALYSIS, 2004, 16 (1-2) : 97 - 100
  • [35] Electrochemical Behaviour of Selected Fenamate NSAIDs at PNAANI Modified Glassy Carbon Electrode
    Kwiecien, Anna
    Sroka, Adam
    Majerz, Irena
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (10)
  • [36] Electrochemical sensor based on phospholipid modified glassy carbon electrode - determination of paraquat
    Tomkova, H.
    Sokolova, R.
    Opletal, T.
    Kucerova, P.
    Kucera, L.
    Souckova, J.
    Skopalova, J.
    Bartak, P.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 821 : 33 - 39
  • [37] Electrochemical sensor for heparin based on a poly(thionine) modified glassy carbon electrode
    Hong Yu Huo
    Hong Qun Luo
    Nian Bing Li
    Microchimica Acta, 2009, 167 : 195 - 199
  • [38] Signal enhancement for electrochemical detection at glassy carbon electrode modified with phenyl layer
    Hong, HG
    Porter, MD
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 578 (01): : 113 - 119
  • [39] Electrochemical Detection of Bisphenol A Using Graphene-Modified Glassy Carbon Electrode
    Ntsendwana, B.
    Mamba, B. B.
    Sampath, S.
    Arotiba, O. A.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (04): : 3501 - 3512
  • [40] Electrochemical determination of ajmalicine using glassy carbon electrode modified with gold nanoparticles
    Eda Mehmeti
    Dalibor M. Stanković
    Sudkate Chaiyo
    Ľubomir Švorc
    Astrid Ortner
    Kurt Kalcher
    Monatshefte für Chemie - Chemical Monthly, 2016, 147 : 1161 - 1166