A New LC L-Filter With In-Series Parallel Resonant Circuit for Single-Phase Grid-Tied Inverter

被引:72
作者
Wu, Weimin [1 ]
Sun, Yunjie [1 ]
Lin, Zhe [1 ]
Tang, Tianhao [1 ]
Blaabjerg, Frede [2 ]
Chung, Henry Shu-Hung [1 ,3 ]
机构
[1] Shanghai Maritime Univ, Res Inst Elect Automat, Shanghai 201306, Peoples R China
[2] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
[3] City Univ Hong Kong, Ctr Smart Energy Convers & Utilizat Res, Kowloon, Hong Kong, Peoples R China
关键词
Common-mode noise; differential-mode noise; electromagnetic interference (EMI); harmonic current; LCL-filter; parallel LC resonant circuit; stiff grid;
D O I
10.1109/TIE.2013.2293703
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
When designing a higher order output power filter for a transformerless grid-tied converter using pulsewidth modulation (PWM), the requirements on the leakage current, the electromagnetic interference (EMI) noise, and the harmonics of the grid-injected current should be addressed. For an LCL-filter-based single-phase grid-tied full-bridge inverter system, it is possible to decrease the total inductance as well as the size and the cost, if the harmonic currents around the switching frequency can be fully suppressed. In this paper, the grid-injected current harmonics and the conducted EMI noise are investigated for the conventional LCL-filter-based system. Based on this, a modified LCL-filter topology using an extra parallel LrCr resonant circuit is proposed to reduce the total inductance value, without increasing the capacitive reactive power. The validity is verified through the experiments on a 500-W 110-V/50-Hz prototype.
引用
收藏
页码:4640 / 4644
页数:5
相关论文
共 14 条
[1]  
[Anonymous], 2009, 154722008 IEEE, P1
[2]  
[Anonymous], 2007, 6210912007 IEC
[3]  
[Anonymous], 2004, SPEC IND SCI MED ISM
[4]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[5]   Leakage Current Reduction in a Single-Phase Bidirectional AC-DC Full-Bridge Inverter [J].
Dong, Dong ;
Luo, Fang ;
Boroyevich, Dushan ;
Mattavelli, Paolo .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (10) :4281-4291
[6]   Composite Nonlinear Feedback Control and Stability Analysis of a Grid-Connected Voltage Source Inverter With LCL Filter [J].
Eren, Suzan ;
Pahlevaninezhad, Majid ;
Bakhshai, Alireza ;
Jain, Praveen K. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (11) :5059-5074
[7]  
Holmes D. G., 2003, Pulse Width Modulation for Power Convert- ers: Principles and Practice, V18
[8]   LQG Servo Controller for the Current Control of LCL Grid-Connected Voltage-Source Converters [J].
Huerta, Francisco ;
Pizarro, Daniel ;
Cobreces, Santiago ;
Rodriguez, Francisco J. ;
Giron, Carlos ;
Rodriguez, Ana .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (11) :4272-4284
[9]   Adaptive Current Control for Grid-Connected Converters With LCL Filter [J].
Massing, Jorge Rodrigo ;
Stefanello, Marcio ;
Gruendling, Hilton Abilio ;
Pinheiro, Humberto .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (12) :4681-4693
[10]   Novel High-Efficiency Three-Level Stacked-Neutral-Point-Clamped Grid-Tied Inverter [J].
Wang, Yong ;
Li, Rui .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (09) :3766-3774