Diagnostic Performance of Copeptin in Patients With Acute Nontraumatic Chest Pain: BWH- TIMI ED Chest Pain Study

被引:9
作者
Sukul, Devraj [1 ]
Bonaca, Marc P. [1 ]
Ruff, Christian T. [1 ]
Kosowsky, Joshua [2 ]
Conrad, Michael [3 ]
Murphy, Sabina A. [1 ]
Sabatine, Marc S. [1 ]
Jarolim, Petr [3 ]
Morrow, David A. [1 ]
机构
[1] Harvard Univ, Brigham & Womens Hosp, Sch Med, TIMI Study Grp,Cardiovasc Div,Dept Med, Boston, MA 02115 USA
[2] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Emergency Med, Boston, MA 02115 USA
[3] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Pathol, Boston, MA 02115 USA
关键词
ACUTE MYOCARDIAL-INFARCTION; RISK STRATIFICATION; TROPONIN-I; PEPTIDE; ASSAYS; VASOPRESSIN; PRECURSOR; RULE;
D O I
10.1002/clc.22244
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundArginine-vasopressin (AVP) is an acute marker of physiologic stress. Copeptin is the C-terminal fragment of vasopressin precursor hormone that is more easily measured than AVP. Studies assessing the utility of copeptin in the diagnosis of myocardial infarction (MI) have demonstrated mixed results. HypothesisThe aim of this study was to test the hypothesis that copeptin improves diagnostic performance when added to troponin for detecting MI in patients presenting to the emergency department with nontraumatic chest pain. MethodsWe measured copeptin, local cardiac troponin I (local cTnI), and a contemporary sensitive cardiac troponin I (sensitive cTnI) at presentation and serially in patients who presented with acute chest pain. A copeptin cutoff of 14 pmol/L was utilized. ResultsMI was diagnosed in 25.7% of patients. Noncoronary acute cardiopulmonary causes of chest pain occurred in 12.8%. Patients with MI had significantly higher copeptin levels than patients with noncardiac chest pain (P < 0.001). The area under the receiver operating characteristic curve (AUC) for copeptin was 0.60 (95% confidence interval: 0.54-0.66), significantly less than the AUC for local cTnI (0.92) or sensitive cTnI (0.96). The combination of copeptin with either the local or sensitive troponin assay (c-statistics 0.92 and 0.95, respectively) did not significantly improve the AUC as compared to either troponin assay alone. This finding persisted in the subgroup of early presenters (6 hours from symptom onset). ConclusionsCopeptin did not improve the diagnostic performance for detecting MI when used alone or in combination with a contemporary sensitive cTnI assay, though our cohort had relatively few early presenters.
引用
收藏
页码:227 / 232
页数:6
相关论文
共 27 条
[1]   ACC/AHA 2007 guide lines for the management of patients with unstable Angina/Non-ST-Elevation myocardial infraction - Executive summary [J].
Anderson, Jeffrey L. ;
Adams, Cynthia D. ;
Antman, Elliott M. ;
Bridges, Charles R. ;
Califf, Robert M. ;
Casey, Donald E., Jr. ;
Chavey, William E., II ;
Fesmire, Francis M. ;
Hochman, Judith S. ;
Levin, Thomas N. ;
Lincoff, A. Michael ;
Peterson, Eric D. ;
Theroux, Pierre ;
Wenger, Nanette Kass ;
Wright, R. Scott ;
Smith, Sidney C., Jr. ;
Jacobs, Alice K. ;
Adams, Cynthia D. ;
Riegel, Barbara .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (07) :652-726
[2]  
Antman EM, 2008, J AM COLL CARDIOL, V51, P2028, DOI [10.1016/j.jacc.2008.04.002, 10.1016/j.jacc.2007.10.001]
[3]  
Bhuiya Farida A, 2010, NCHS Data Brief, P1
[4]   Rapid Exclusion of Acute Myocardial Infarction in Patients With Undetectable Troponin Using a High-Sensitivity Assay [J].
Body, Richard ;
Carley, Simon ;
McDowell, Garry ;
Jaffe, Allan S. ;
France, Michael ;
Cruickshank, Kennedy ;
Wibberley, Christopher ;
Nuttall, Michelle ;
Mackway-Jones, Kevin .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (13) :1333-1339
[5]   Use of High-Sensitivity Troponin Assays Predicts Mortality in Patients With Normal Conventional Troponin Assays on Admission-Insights From a Meta-Analysis [J].
Chatterjee, Saurav ;
Kim, Jiwon ;
Dahhan, Ali ;
Choudhary, Gaurav ;
Sharma, Satish ;
Wu, Wen-Chih .
CLINICAL CARDIOLOGY, 2013, 36 (11) :649-653
[6]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[7]   High-sensitive cardiac troponin T outperforms novel diagnostic biomarkers in patients with acute chest pain [J].
Eggers, Kai M. ;
Venge, Per ;
Lindahl, Bertil .
CLINICA CHIMICA ACTA, 2012, 413 (13-14) :1135-1140
[8]   Copeptin Does Not Add Diagnostic Information to High-Sensitivity Troponin T in Low- to Intermediate-Risk Patients with Acute Chest Pain: Results from the Rule Out Myocardial Infarction by Computed Tomography (ROMICAT) Study [J].
Karakas, Mahir ;
Januzzi, James L., Jr. ;
Meyer, Julia ;
Lee, Hang ;
Schlett, Christopher L. ;
Truong, Quynh A. ;
Rottbauer, Wolfgang ;
Bamberg, Fabian ;
Dasdemir, Selcuk ;
Hoffmann, Udo ;
Koenig, Wolfgang .
CLINICAL CHEMISTRY, 2011, 57 (08) :1137-1145
[9]  
Katan M, 2008, NEUROENDOCRINOL LETT, V29, P341
[10]   Copeptin Improves Early Diagnosis of Acute Myocardial Infarction [J].
Keller, Till ;
Tzikas, Stergios ;
Zeller, Tanja ;
Czyz, Ewa ;
Lillpopp, Lars ;
Ojeda, Francisco M. ;
Roth, Alexander ;
Bickel, Christoph ;
Baldus, Stephan ;
Sinning, Christoph R. ;
Wild, Philipp S. ;
Lubos, Edith ;
Peetz, Dirk ;
Kunde, Jan ;
Hartmann, Oliver ;
Bergmann, Andreas ;
Post, Felix ;
Lackner, Karl J. ;
Genth-Zotz, Sabine ;
Nicaud, Viviane ;
Tiret, Laurence ;
Muenzel, Thomas ;
Blankenberg, Stefan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (19) :2096-2106