The influence of lightning induced voltage on the distribution power line polymer insulators

被引:7
|
作者
Izadi, Mahdi [1 ,2 ]
Abd Rahman, Muhammad Syahmi [1 ]
Ab-Kadir, Mohd Zainal Abidin [1 ]
Gomes, Chandima [1 ]
Jasni, Jasronita [1 ]
Hajikhani, Maryam [1 ]
机构
[1] Univ Putra Malaysia, Fac Engn, Ctr Electromagnet & Lightning Protect Res CELP, Serdang, Malaysia
[2] Islamic Azad Univ, Dept Elect Engn, Firoozkooh Branch, Firoozkooh, Iran
来源
PLOS ONE | 2017年 / 12卷 / 02期
关键词
WIRES;
D O I
10.1371/journal.pone.0172118
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Protection of medium voltage (MV) overhead lines against the indirect effects of lightning is an important issue in Malaysia and other tropical countries. Protection of these lines against the indirect effects of lightning is a major concern and can be improved by several ways. The choice of insulator to be used for instance, between the glass, ceramic or polymer, can help to improve the line performance from the perspective of increasing the breakdown strength. In this paper, the electrical performance of a 10 kV polymer insulator under different conditions for impulse, weather and insulator angle with respect to a cross-arm were studied (both experimental and modelling) and the results were discussed accordingly. Results show that the weather and insulator angle (with respect to the cross-arm) are surprisingly influenced the values of breakdown voltage and leakage current for both negative and positive impulses. Therefore, in order to select a proper protection system for MV lines against lightning induced voltage, consideration of the local information concerning the weather and also the insulator angles with respect to the cross-arm are very useful for line stability and performance.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Induced voltage measurements on an experimental distribution line during nearby rocket triggered lightning flashes
    Barker, PP
    Short, TA
    EybertBerard, AR
    Berlandis, JP
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (02) : 980 - 995
  • [22] Equivalent Circuit of Distribution Line for Lightning-Induced Voltage Analysis Using Analytical Formulas
    Sekioka, Shozo
    ELECTRICAL ENGINEERING IN JAPAN, 2017, 199 (03) : 26 - 34
  • [23] Equivalent circuit of distribution line for lightning-induced voltage analysis using analytical formulas
    Sekioka S.
    Sekioka, Shozo (sekioka@elec.shonan-it.ac.jp), 1600, Institute of Electrical Engineers of Japan (136): : 610 - 616
  • [24] Effects of Surge Protective Devices on Overhead Power Line Induced Voltage From Natural Lightning
    Cai, Li
    Wang, Jianguo
    Zhou, Mi
    Li, Xianqiang
    Zhang, Yijun
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2013, 55 (06) : 1201 - 1209
  • [25] Experiments of Lightning Induced Overvoltages on a Real-size Overhead Power Distribution Line
    Yokoyama, Shigeru
    Sekioka, Shozo
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,
  • [26] Induced voltage approach by lightning in the distribution lines.
    Henao-Cespedes, V.
    Fano, W. G.
    Diaz-Cadavid, L. F.
    Cano-Plata, E. A.
    2016 IEEE GLOBAL ELECTROMAGNETIC COMPATIBILITY CONFERENCE (GEMCCON), 2016,
  • [27] Lightning-induced voltage analysis on a three-phase compact distribution line considering different line models
    De Conti, Alberto
    Leal, Osis E. S.
    Silva, Alex C.
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 187
  • [28] Evaluation of lightning location using measured induced voltage obtained from distribution power networks
    Izadi, Mahdi
    Kadir, Mohd Zainal Abidin Ab
    Osman, Miszaina
    Hajikhani, Maryam
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2021, 29 (12) : 2288 - 2305
  • [29] Calculation methods for lightning impulse voltage distribution in power transformers
    Alexandru, Boruz Mircea
    Mihai, Mircea Paul
    Marian, Ciontu
    Ion, Mircea
    2014 INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT (OPTIM), 2014, : 71 - 76
  • [30] Study of the Induced Voltage on an Overhead Line due to Lightning Discharge
    Gayen, Arun
    Dhar, Anirban
    Das, B. N.
    Poddar, D. R.
    INCEMIC 2006: 9TH INTERNATIONAL CONFERENCE ON ELECTROMAGNETIC INTERFERENCE AND COMPATIBILITY, PROCEEDINGS, 2006, : 353 - 357