Lead fixation in deep brain stimulation: comparison of three lead anchoring devices in China

被引:3
作者
Wang, Tao [1 ]
Pan, Yixin [1 ]
Zhang, Chencheng [1 ]
Zhan, Shikun [1 ]
Sun, Bomin [1 ]
Li, Dianyou [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Funct Neurosurg, Ruijin Hosp, Sch Med, 197 Ruijin Second Rd, Shanghai 200025, Peoples R China
基金
中国国家自然科学基金;
关键词
Deep brain stimulation; Lead anchoring devices; Radiography;
D O I
10.1186/s12893-019-0558-9
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundThe accuracy of deep brain stimulation (DBS) depends on precise electrode positioning, which has been pursued for ideal treatment outcomes. As a critical component of DBS, the fixation performance of lead anchoring devices has been widely studied. Possible reasons for lead shift were analyzed in the current study and we further provided effective solutions to reduce potential manual errors.MethodsSeventy-nine patients who received DBS implantations at the Ruijin Hospital from April to November 2017 were retrospectively reviewed. Intraoperative lead shifts were measured by C-arm fluoroscopy. Lead adjustment counts were recorded and compared among three lead fixation devices: Stimloc (TM) (Medtronic, Minneapolis, MN, USA), TouchLoc (SceneRay, Suzhou, China), and the traditional lead anchoring device.ResultsMean ( SD) distances of lead shifts were 0.29 +/- 2.42mm in Stimloc devices, 0.43 +/- 0.55mm in TouchLoc devices, and 1.52 +/- 1.05mm in traditional devices (p<0.0001). Average numbers of adjustments in this series were 0.3 +/- 0.5 in Stimloc devices, 0.3 +/- 1.3 in TouchLoc devices, and 1.1 +/- 1.0 in traditional devices (p=0.0001). Pairwise comparisons among the three devices (TouchLoc vs. Stimloc: p=0.273; TouchLoc vs. Traditional: p=0.0001; Stimloc vs. traditional: p<0.0001) suggested significant differences, which were mainly attributed to the traditional devices.Conclusions Three lead anchoring devices have been compared for their performance in the accuracy of lead fixation, in which the newly designed lead fixation devices have presented its advantages to the traditional one. In addition to the application of the Stimloc and TouchLoc devices, verification by C-arm fluoroscopy should be performed to provide an intuitive view of the depth deviation of electrode position during DBS electrode implantation.
引用
收藏
页数:7
相关论文
共 13 条
  • [1] Bonde EH, 2014, Patent No. [US20140155860A1, 20140155860]
  • [2] Subthalamus Deep Brain Stimulation for Primary Dystonia Patients: A Long-Term Follow-up Study
    Cao, Chunyan
    Pan, Yixin
    Li, Dianyou
    Zhan, Shikun
    Zhang, Jing
    Sun, Bomin
    [J]. MOVEMENT DISORDERS, 2013, 28 (13) : 1877 - 1882
  • [3] Neurostimulation Devices for the Treatment of Neurologic Disorders
    Edwards, Christine A.
    Kouzani, Abbas
    Lee, Kendall H.
    Ross, Erika K.
    [J]. MAYO CLINIC PROCEEDINGS, 2017, 92 (09) : 1427 - 1444
  • [4] Deep Brain Stimulation in China: Present and Future
    Hu, Wen-Han
    Zhang, Kai
    Meng, Fan-Gang
    Ma, Yu
    Zhang, Jian-Guo
    [J]. NEUROMODULATION, 2012, 15 (03): : 251 - 259
  • [5] Location, location, location: Validating the position of deep brain stimulation electrodes
    Israel, Zvi
    Bergman, Hagai
    [J]. MOVEMENT DISORDERS, 2016, 31 (03) : 259 - 259
  • [6] Subthalamic nucleus deep brain stimulation for Parkinson's disease: 8 years of follow-up
    Li D.
    Cao C.
    Zhang J.
    Zhan S.
    Chen S.
    Sun B.
    [J]. Translational Neurodegeneration, 2 (1)
  • [7] Intraoperative x-ray to measure distance between DBS leads: A reliability study
    Metman, Leo Verhagen
    Pilitsis, Julie G.
    Stebbins, Glenn T.
    Bot, Maarten
    Bakay, Roy A. E.
    [J]. MOVEMENT DISORDERS, 2012, 27 (08) : 1056 - 1059
  • [8] Postoperative lead migration in deep brain stimulation surgery: Incidence, risk factors, and clinical impact
    Morishita, Takashi
    Hilliard, Justin D.
    Okun, Michael S.
    Neal, Dan
    Nestor, Kelsey A.
    Peace, David
    Hozouri, Alden A.
    Davidson, Mark R.
    Bova, Francis J.
    Sporrer, Justin M.
    Oyama, Genko
    Foote, Kelly D.
    [J]. PLOS ONE, 2017, 12 (09):
  • [9] Deep brain stimulation lead fixation after Stimloc failure
    Patel, Nitesh V.
    Barrese, James
    DiTota, Robert J.
    Hargreaves, Eric L.
    Danish, Shabbar F.
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2012, 19 (12) : 1715 - 1718
  • [10] Intraoperative Computed Tomography for Deep Brain Stimulation Surgery: Technique and Accuracy Assessment
    Shahlaie, Kiarash
    Larson, Paul S.
    Starr, Philip A.
    [J]. NEUROSURGERY, 2011, 68 (03) : 114 - 124