共 32 条
Influences of different diluents on ignition delay of syngas at gas turbine conditions: A numerical study
被引:7
作者:
He, Dong
[1
]
Yan, Weiping
[1
]
机构:
[1] North China Elect Power Univ, MOEs Key Lab Condit Monitoring & Control Power Pl, Baoding 071003, Peoples R China
关键词:
Ignition delay;
Reaction mechanism;
Combustion;
Kinetic modeling;
Syngas;
SHOCK-TUBE;
COMBUSTION;
MIXTURES;
OXIDATION;
HYDROGEN;
METHANE;
BLENDS;
OXYGEN;
MODEL;
D O I:
10.1016/j.cjche.2016.06.003
中图分类号:
TQ [化学工业];
学科分类号:
0817 ;
摘要:
Ignition delay of syngas is an important factor that affects stable operation of combustor and adding diluents to syngas can reduce NOx emission. This paper used H2O, CO2 and N-2 as diluents and calculated ignition delay of syngas in temperature range of 900-1400 K and at pressures of 10 and 30 atmrespectively. In high temperature range, comparing with N-2 dilution, adding H2O and CO2 can significantly inhibit autoignition of syngas because they have higher collision efficiencies in reaction H + O-2 (+M) = HO2 (+M). As for low temperature conditions, adding H2O can increase reactivity of syngas, especially under high pressure, because of its high collision efficiency in reaction H2O2 (+M)= 2OH (+M). Comparing with different dilution rates shows that for syngas and operating conditions in this paper, adding N-2 mainly influences temperature rising process of syngas combustion, thus inhibiting reactivity of syngas. In addition, this paper calculated ignition delay of syngas at different equivalence ratios (phi= 0.5, 1.0). Higher equivalence ratio (phi <= 1) means that less air (especially N-2) needs to be heated, thus promoting ignition of syngas. (C) 2016 The Chemical Industry and Engineering Society of China, and Chemical Industry Press. All rights reserved.
引用
收藏
页码:79 / 88
页数:10
相关论文