An economic comparison and evaluation of two geothermal district heating systems for advanced exergoeconomic analysis

被引:29
作者
Kecebas, Pinar [1 ]
Gokgedik, Harun [1 ,2 ]
Alkan, Mehmet Ali [3 ]
Kecebas, Ali [4 ]
机构
[1] Mugla Sitki Kocman Univ, Grad Sch Nat & Appl Sci, Dept Energy, TR-48000 Mugla, Turkey
[2] Suleyman Demirel Univ, Grad Sch Nat & Appl Sci, Dept Energy Syst Engn, TR-32260 Isparta, Turkey
[3] Mugla Sitki Kocman Univ, Ula Ali Kocman Vocat High Sch, Dept Elect & Energy, TR-48640 Ula, Mugla, Turkey
[4] Mugla Sitki Kocman Univ, Fac Technol, Dept Energy Syst Engn, TR-48000 Mugla, Turkey
关键词
Geothermal energy; District heating system; Advanced exergoeconomic analysis; Exergy destruction cost; Investment cost; Splitting process; EXERGY DESTRUCTION; INVESTMENT COSTS; THERMAL-SYSTEMS;
D O I
10.1016/j.enconman.2014.04.068
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper refers to an economic comparison and evaluation of two geothermal district heating systems (GDHSs) under same reference state condition and mechanic/economic parameters by using an advanced exergoeconomic analysis. In this analysis, costs of investment and exergy destruction of each component for the thermal systems such as the Afyon and Saraykoy GDHSs were split into endogenous/exogenous and unavoidable/avoidable parts, and were also compared with each other for the first time. The results obtained show that the advanced exergoeconomic analysis makes the information more accurate and useful, and supplies additional information that cannot be provided by the conversional analysis. Furthermore, the Afyon GDHS can be made more cost effectiveness, removing the system components' irreversibilities, technical-economic limitations, and poorly chosen manufacturing methods, according to the Saraykoy GDHS. The majority of the components in the Saraykoy GDHS are to operate more economically than those in the Afyon GDHS. As a result, the usefulness of this method was clearly demonstrated comparing both the systems. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:471 / 480
页数:10
相关论文
共 20 条
[1]   Advanced exergoeconomic analysis of an electricity-generating facility that operates with natural gas [J].
Acikkalp, Emin ;
Aras, Haydar ;
Hepbasli, Arif .
ENERGY CONVERSION AND MANAGEMENT, 2014, 78 :452-460
[2]  
Bejan A, 1996, THERMAL DESIGN OPTIM
[3]   Avoidable thermodynamic inefficiencies and costs in an externally fired combined cycle power plant [J].
Cziesla, F ;
Tsatsaronis, G ;
Gao, ZL .
ENERGY, 2006, 31 (10-11) :1472-1489
[4]   A comparative study on conventional and advanced exergetic analyses of geothermal district heating systems based on actual operational data [J].
Hepbasli, Arif ;
Kecebas, Ali .
ENERGY AND BUILDINGS, 2013, 61 :193-201
[5]   Conventional and advanced exergoeconomic analyses of geothermal district heating systems [J].
Kecebas, Ali ;
Hepbasli, Arif .
ENERGY AND BUILDINGS, 2014, 69 :434-441
[6]   Performance investigation of the Afyon geothermal district heating system for building applications: Exergy analysis [J].
Kecebas, Ali ;
Kayfeci, Muhammet ;
Gedik, Engin .
APPLIED THERMAL ENGINEERING, 2011, 31 (6-7) :1229-1237
[7]   Performance and thermo-economic assessments of geothermal district heating system: A case study in Afyon, Turkey [J].
Kecebas, Ali .
RENEWABLE ENERGY, 2011, 36 (01) :77-83
[8]   Advanced exergetic analysis: Approaches for splitting the exergy destruction into endogenous and exogenous parts [J].
Kelly, S. ;
Tsatsaronis, G. ;
Morosuk, T. .
ENERGY, 2009, 34 (03) :384-391
[9]  
Kelly S.:., 2008, Energy Systems Improvement based on Endogenous and Exogenous Exergy Destruction, volume 572 of VDI Fortschritt-Berichte
[10]   SPECO: A systematic and general methodology for calculating efficiencies and costs in thermal systems [J].
Lazzaretto, A ;
Tsatsaronis, G .
ENERGY, 2006, 31 (8-9) :1257-1289