共 49 条
Electrodialysis ion-exchange membrane bioreactor (EDIMB) to remove nitrate from water: Optimization of operating conditions and kinetics analysis
被引:11
作者:
Gu, Mengqi
[1
]
Wang, Yanan
[1
]
Wan, Dongjin
[1
,2
,3
]
Shi, Yahui
[1
,2
]
He, Qiaochong
[1
,2
]
机构:
[1] Henan Univ Technol, Coll Environm Engn, Zhengzhou 450001, Henan, Peoples R China
[2] Henan Int Joint Lab Environm Pollut Remediat & Gr, Zhengzhou 450001, Henan, Peoples R China
[3] Henan Univ Technol, Inst Carbon Neutral, Zhengzhou 450001, Henan, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Nitrate;
Electrodialysis;
Denitrification;
Kinetics;
Microorganism;
AUTOTROPHIC DENITRIFICATION;
MICROBIAL COMMUNITY;
HETEROTROPHIC DENITRIFICATION;
CONTAMINATED GROUNDWATER;
WASTE-WATER;
AMMONIUM;
SYSTEM;
IDENTIFICATION;
PERCHLORATE;
PHOSPHORUS;
D O I:
10.1016/j.scitotenv.2022.156046
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
Nitrate pollution has become a worldwide problem. In this study, we remove nitrate from water by electrodialysis ion-exchange membrane bioreactor (EDIMB) and enabling simultaneous nitrate enrichment and denitrification. In this reactor, nitrate migrated from the water chamber to the biological chamber via electrodialysis and was degraded by microorganisms. The effects of voltage and biomass concentration on the reactor performance were examined, and the kinetics data of the water chamber and biological chamber were fitted. The experimental results showed that the migration of nitrate in the water chamber conformed to the first-order model, and the constructed zero-Michaelis-Menten model described changes in nitrate concentration in the biological chamber. Furthermore, when the inflow nitrate concentration was 40 mg N/L, 5 V was the best voltage, and 3.00 g VSS/L was the best biomass concentration. The nitrate removal rate in the water chamber was 98.94%, and there was no accumulation of nitrate or nitrite in the biological chamber. Compared with traditional ED processes, the nitrate removal efficiency was 8.86% higher, and the current efficiency was 22.14% higher. The total organic carbon (TOC) of the water chamber was only 1.43 mg C/L, which proves that the structure of the EDIMB confined the denitrifying bacteria and organic carbon donors in the biological chamber and avoided secondary pollution in the water chamber. Microbial community analysis showed that Thauera (66.06%) was the dominant bacterium in the EDIMB system, and Azoarcus (9.81%) was a minor denitrifying genus.