Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT

被引:15
作者
Matenine, Dmitri [1 ]
Mascolo-Fortin, Julia [1 ]
Goussard, Yves [2 ]
Despres, Philippe [1 ,3 ,4 ,5 ]
机构
[1] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ G1V 0A6, Canada
[2] Ecole Polytech, Dept Genie Elect, Inst Genie Biomed, Montreal, PQ H3C 3A7, Canada
[3] Univ Laval, Ctr Rech Canc, Quebec City, PQ G1V 0A6, Canada
[4] CHU Quebec, Dept Radiooncol, Quebec City, PQ G1R 2J6, Canada
[5] CHU Quebec, Ctr Rech, Quebec City, PQ G1R 2J6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
optical CT; iterative reconstruction; cone-beam reconstruction; total variation minimization; GEL-DOSIMETRY I; COMPUTED-TOMOGRAPHY; TRANSMISSION TOMOGRAPHY; 3D DOSIMETRY; RESOLUTION; SCANNER; PHYSICS;
D O I
10.1118/1.4931604
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. Methods: This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numerical simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. Results: The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. Conclusions: The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can potentially improve the rendering of spatial features and reduce cone-beam optical CT artifacts. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:6376 / 6386
页数:11
相关论文
共 32 条
[1]  
[Anonymous], 2010, Thrust: A parallel template library
[2]  
[Anonymous], 2010, NVIDIA CUDA REF MAN
[3]   Three-dimensional dose verification for intensity-modulated radiation therapy in the radiological physics centre head-and-neck phantom using optical computed tomography scans of ferrous xylenol-orange gel dosimeters [J].
Babic, Steven ;
Battista, Jerry ;
Jordan, Kevin .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04) :1281-1291
[4]   Polymer gel dosimetry [J].
Baldock, C. ;
De Deene, Y. ;
Doran, S. ;
Ibbott, G. ;
Jirasek, A. ;
Lepage, M. ;
McAuley, K. B. ;
Oldham, M. ;
Schreiner, L. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) :R1-R63
[5]   Ordered subset reconstruction for x-ray CT [J].
Beekman, FJ ;
Kamphuis, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (07) :1835-1844
[7]   A prototype fan-beam optical CT scanner for 3D dosimetry [J].
Campbell, Warren G. ;
Rudko, D. A. ;
Braam, Nicolas A. ;
Wells, Derek M. ;
Jirasek, Andrew .
MEDICAL PHYSICS, 2013, 40 (06)
[8]   Computational simulations of the influence of noise in optical CT reconstruction [J].
De Deene, Yves .
8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
[9]  
Doran Simon J., 2009, Journal of Physics: Conference Series, V164, DOI 10.1088/1742-6596/164/1/012020
[10]   Eliminating the need for refractive index matching in optical CT scanners for radiotherapy dosimetry: I. Concept and simulations [J].
Doran, Simon J. ;
Yatigammana, Dylan N. B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (03) :665-683