Risk factors for a radiolucent line around the acetabular component with an interface bioactive bone cement technique after primary cemented total hip arthroplasty PROGNOSTIC FACTORS FOR A RADIOLUCENT LINE AND IMPROVEMENT OF THE CEMENT-BONE INTERFACE AROUND CEMENTED ACETABULAR COMPONENT WITH AN INTERFACE BIOACTIVE BONE CEMENT TECHNIQUE

被引:0
|
作者
Miyamoto, S. [1 ]
Iida, S. [1 ]
Suzuki, C. [1 ]
Nakatani, T. [1 ]
Kawarai, Y. [1 ]
Nakamura, J. [1 ]
Orita, S. [1 ]
Ohtori, S. [1 ]
机构
[1] Matsudo City Gen Hosp, Dept Orthopaed Surg, Matsudo, Chiba, Japan
来源
BONE & JOINT OPEN | 2021年 / 2卷 / 05期
关键词
Total hip arthroplasty; Cement-bone interface; Acetabular component; Cemented; Interface bioactive bone cement technique; Hydroxyapatite; LOW-FRICTION ARTHROPLASTY; CONCISE FOLLOW-UP; DEVELOPMENTAL DYSPLASIA; FEMORAL-HEAD; ASEPTIC FAILURE; FIXATION; REPLACEMENT; RECONSTRUCTION; DISLOCATION; MIGRATION;
D O I
10.1302/2633-1462.25.BJO-2021-0010.R1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims The main aims were to identify risk factors predictive of a radiolucent line (RLL) around the acetabular component with an interface bioactive bone cement (IBBC) technique in the first year after THA, and evaluate whether these risk factors influence the development of RLLs at five and ten years after THA. Methods A retrospective review was undertaken of 980 primary cemented THAs in 876 patients using cemented acetabular components with the IBBC technique. The outcome variable was any Rib that could be observed around the acetabular component at the first year after THA. Univariate analyses with univariate logistic regression and multivariate analyses with exact logistic regression were performed to identify risk factors for any RLLs based on radiological classification of hip osteoarthritis. Results RLLs were detected in 27.2% of patients one year postoperatively. In multivariate regression analysis controlling for confounders, atrophic osteoarthritis (odds ratio (OR) 2.17 (95% confidence interval (CI), 1.04 to 4.49); p = 0.038) and 26 mm (OR 3.23 (95% CI 1.85 to 5.66); p < 0.001) or 28 mm head diameter (OR 3.64 (95% Cl 2.07 to 6.41); p < 0.001) had a significantly greater risk for any Fills one year after surgery. Structural bone graft (OR 0.19 (95% CI 0.13 to 0.29) p < 0.001) and location of the hip centre within the true acetabular region (OR 0.15 (95% CI 0.09 to 0.24); p < 0.001) were significantly less prognostic. Improvement of the cement-bone interface including complete disappearance and poorly defined RLLs was identified in 15.1% of patients. KaplanMeier survival analysis for the acetabular component at ten years with revision of the acetabular component for aseptic loosening as the end point was 100.0% with a RLL and 99.1% without a RLL (95% CI 97.9 to 100). With revision of the acetabular component for any reason as the end point, the survival rate was 99.2% with a RLL (95% Cl 97.6 to 100) and 96.5% without a RLL (95% CI 93.4 to 99.7). Conclusion This study demonstrates that acetabular bone quality, head diameter, structural bone graft, and hip centre position may influence the presence of the any RLL.
引用
收藏
页码:278 / 292
页数:15
相关论文
共 6 条
  • [1] Total Hip Arthroplasty around the Inception of the Interface Bioactive Bone Cement Technique
    Oonishi, Hiroyuki
    Ohashi, Hirotsugu
    Kawahara, Ikuo
    CLINICS IN ORTHOPEDIC SURGERY, 2016, 8 (03) : 237 - 242
  • [2] Minimum 5 year follow-up of clinical and radiographic results of cemented acetabular components with an interface bioactive bone cement technique in primary cemented total hip arthroplasty
    Miyamoto, Shuichi
    Iida, Satoshi
    Suzuki, Chiho
    Nakatani, Takushi
    Kawarai, Yuya
    Nakamura, Junichi
    Orita, Sumihisa
    Ohtori, Seiji
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (01) : 139 - 147
  • [3] Histologic findings at 14 and 18 years after cemented total hip arthroplasty with interface bioactive bone cement technique
    Kim, Sok Chol
    Ohashi, Hirotsugu
    Oonishi, Hiroyuki, Jr.
    Oonishi, Hironobu
    JOURNAL OF ARTHROPLASTY, 2007, 22 (07) : 1067 - 1069
  • [4] Minimum 5 year follow-up of clinical and radiographic results of cemented acetabular components with an interface bioactive bone cement technique in primary cemented total hip arthroplasty
    Shuichi Miyamoto
    Satoshi Iida
    Chiho Suzuki
    Takushi Nakatani
    Yuya Kawarai
    Junichi Nakamura
    Sumihisa Orita
    Seiji Ohtori
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 139 - 147
  • [5] Radiological evaluation of the femoral component fixed with interface bioactive bone cement in revision total hip arthroplasty
    Fujita, Hiroshi
    Oonishi, Hironobu
    Ito, Shigeru
    Kim, Seok Cheol
    Doukawa, Hirofumi
    JOURNAL OF ARTHROPLASTY, 2008, 23 (05) : 689 - 693
  • [6] The effect of cement mantle thickness on strain energy density distribution and prediction of bone density changes around cemented acetabular component
    Sanjay, Devismita
    Mondal, Subrata
    Bhutani, Richa
    Ghosh, Rajesh
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (09) : 912 - 921