Non-invasive assessment of liver fibrosis in patients with hepatitis C: Shear wave elastography and colour Doppler velocity profile technique versus liver biopsy

被引:13
作者
Moustafa, Ehab F. [1 ]
Makhlouf, Nahed [1 ]
Hassany, Sahar M. [1 ]
Helmy, Ahmed [1 ]
Nasr, Ahmed [1 ]
Othman, Moustafa [2 ]
Seif, Hany [2 ]
Darwish, Manal [3 ]
Hassan, Howayda [4 ]
Hessen, Mohamed [1 ]
机构
[1] Assiut Univ, Trop Med & Gastroenterol Dept, Assiut, Egypt
[2] Assiut Univ, Radiol Dept, Assiut, Egypt
[3] Assiut Univ, Publ Hlth & Community Med Dept, Assiut, Egypt
[4] Assiut Univ, Pathol Dept, Assiut, Egypt
关键词
Chronic HCV; Shear wave elastography; Doppler ultrasound; Liver fibrosis; TRANSIENT ELASTOGRAPHY; ACCURACY; VIRUS;
D O I
10.1016/j.ajg.2017.01.004
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims: Determination of the presence and degree of liver fibrosis is essential for the prognosis and treatment of patients with chronic hepatitis C. Non-invasive methods of assessing fibrosis have been developed to reduce the need for biopsy. We determined the efficacy of shear wave elastography (SWE) and colour Doppler velocity as non-invasive methods for the assessment of liver fibrosis compared to liver biopsy among patients with chronic hepatitis C virus (HCV) infection. Patients and methods: In total, 117 patients with chronic HCV infection and 50 healthy age-and sex-matched control subjects were included. For each patient and control, abdominal ultrasonography, Doppler ultrasonography of the right portal vein (PV), and SWE were performed, whereas liver biopsy was performed for patients. Results: The mean value of the right PV maximum velocity was lower in patients with different stages of fibrosis than in controls (p < 0.001). The mean value of liver stiffness determined by SWE was significantly higher in patients with different stages of fibrosis than in controls. Cutoff values for liver stiffness determined by SWE for assessing fibrosis stages were F2 >= P4.815, F3 >= P6.335, and F4 = 7.540 with a sensitivity of 84.6%, 96.2%, and 100.0%; specificity of 88.5%, 93.8%, and 100.0%; positive predictive value (PPV) of 93.6%, 98.0%, and 100.0%; negative predictive value (NPV) of 74.2%, 88.2%, and 100.0%; and overall accuracy of 85.9%, 95.6%, and 100.0% [ area under the ROC curve (AUC): 0.89, 0.96, and 1.0], respectively. Cutoff values for the right PV maximum velocity for assessing fibrosis stages were F2 < 23.4, F3 < 21, and F4 < 20 with a sensitivity of 65.0%, 57.4%, and 57.1%; specificity of 59.8%, 76.4%, and 75.5%; PPV of 33.8%, 58.3%, and 32.0%; NPV of 84.4%, 75.7%, and 89.7%; and overall accuracy of 61.1%, 69.5%, and 72.5% (AUC: 0.614, 0.696, and 0.625), respectively. Conclusion: SWE is effective for the non-invasive assessment of liver fibrosis in patients with HCV infection. SWE provides a more accurate correlation with liver fibrosis stage than colour Doppler velocity profile for the assessment of liver fibrosis, especially in advanced stages (F3 and F4). (C) 2017 Pan-Arab Association of Gastroenterology. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:6 / 12
页数:7
相关论文
共 23 条
  • [21] Systematic review: non-invasive methods of fibrosis analysis in chronic hepatitis C
    Smith, J. O.
    Sterling, R. K.
    [J]. ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2009, 30 (06) : 557 - 576
  • [22] Tziafalia Christina, 2006, J Gastrointestin Liver Dis, V15, P343
  • [23] Liver Fibrosis Evaluation Using Real-time Shear Wave Elastography in Hepatitis C-Monoinfected and Human Immunodeficiency Virus/Hepatitis C-Coinfected Patients
    Verlinden, Wim
    Bourgeois, Stefan
    Gigase, Pierre
    Thienpont, Clara
    Vonghia, Luisa
    Vanwolleghem, Thomas
    Michielsen, Peter
    Francque, Sven
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (06) : 1299 - 1308