Life cycle assessment of solar aided coal-fired power system with and without heat storage

被引:69
作者
Zhai, Rongrong [1 ]
Li, Chao [1 ]
Chen, Ying [1 ]
Yang, Yongping [1 ]
Patchigolla, Kumar [2 ]
Oakey, John E. [2 ]
机构
[1] North China Elect Power Univ, Sch Energy Power & Mech Engn, Beijing 102206, Peoples R China
[2] Cranfield Univ, Power Engn Ctr, Bedford MK43 0AL, Beds, England
基金
英国工程与自然科学研究理事会;
关键词
Coal-fired power system; Grey relation analysis; Life cycle assessment; Solar aided coal-fired power system; GENERATION SYSTEM; PLANTS; ENERGY; CHINA; OPTIMIZATION; PERFORMANCE; STRATEGIES; EMISSIONS;
D O I
10.1016/j.enconman.2015.12.053
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pollutant emissions from coal-fired power system have been receiving increasing attention over the past few years. Integration of solar thermal energy can greatly reduce pollutant emissions from these power stations. The performances of coal-fired power system (S1), solar aided coal-fired power system with thermal storage (S2), and solar aided coal-fired power system without thermal storage (S3) with three capacities of each kind of system (i.e., nine subsystems) were analyzed over the entire life span. The pollutant emissions and primary energy consumptions (PECs) of S1, S2, and S3 were estimated using life cycle assessment (LCA). The evaluation value of global warming potential (GWP), acidification potential (AP), respiratory effects potential (REP) and PEC were obtained based on the LCA results. Furthermore, the system investments were estimated, and grey relation theory was used to evaluate the performance of the three types of systems comprehensively. Finally, in order to find the effect of some main factors on the solar aided coal-fired power system (SACFPS), uncertainty analysis has been carried out. The LCA results show that the pollutant emissions and PEC mainly take place in the fuel processing and operation stages for all three system types, and S2 performs the best among the three systems based on the grey relation analysis results. And the uncertainty analysis shows that with longer life span, the power system have better performance; with higher coal price, the power system will have worse performance; with lower solar collector field cost, the solar aided coal-fired power system will be more profitable than the base-case coal-fired power system. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:453 / 465
页数:13
相关论文
共 36 条
[1]   Solar aided power generation of a 300 MW lignite fired power plant combined with line-focus parabolic trough collectors field [J].
Bakos, G. C. ;
Tsechelidou, Ch. .
RENEWABLE ENERGY, 2013, 60 :540-547
[2]   Life Cycle Assessment of a Parabolic Trough Concentrating Solar Power Plant and the Impacts of Key Design Alternatives [J].
Burkhardt, John J., III ;
Heath, Garvin A. ;
Turchi, Craig S. .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (06) :2457-2464
[3]  
Chan YH, 2015, ENERGY CONVERS MANAG
[4]   Environmental impacts of energy [J].
Dincer, I .
ENERGY POLICY, 1999, 27 (14) :845-854
[5]  
Electric Power Planning Engineering Institute, 2013, THERM POW ENG DES RE
[6]   An ecological and economic assessment of absorption-enhanced-reforming (AER) biomass gasification [J].
Heffels, Tobias ;
McKenna, Russell ;
Fichtner, Wolf .
ENERGY CONVERSION AND MANAGEMENT, 2014, 77 :535-544
[7]   A typical solar-coal hybrid power plant in China [J].
Hong, H. ;
Peng, S. ;
Zhao, Y. ;
Liu, Q. ;
Jin, H. .
PROCEEDINGS OF THE SOLARPACES 2013 INTERNATIONAL CONFERENCE, 2014, 49 :1777-1783
[8]   Performance evaluation of solar aided feedwater heating of coal-fired power generation (SAFHCPG) system under different operating conditions [J].
Hou Hong-juan ;
Yu Zhen-yue ;
Yang Yong-ping ;
Chen Si ;
Luo Na ;
Wu Junjie .
APPLIED ENERGY, 2013, 112 :710-718
[9]  
Huang SY, 2012, PRINCIPLE TECHNOLOGY
[10]   Life cycle assessment of a solar combined cooling heating and power system in different operation strategies [J].
Jing, You-Yin ;
Bai, He ;
Wang, Jiang-Jiang ;
Liu, Lei .
APPLIED ENERGY, 2012, 92 :843-853