Monte-Carlo simulations of a neutron source generated with electron linear accelerator

被引:0
|
作者
Wasilewski, Adam [1 ]
Wronka, Slawomir [1 ]
机构
[1] Andrzej Soltan Inst Nucl Studies, Estab Nucl Equipment, PL-05400 Otwock, Poland
关键词
Fluka; Monte-Carlo simulations; neutron generation; electron linear accelerator; X-ray converter;
D O I
暂无
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Neutron generator consisting of an electron linear accelerator and a tungsten X-ray converter can produce a neutron flux of 10(9)n/s and 10(11)n/s at electron energies of 10 and 15 MeV, respectively, with an electron beam intensity of 10(14)e/s which means 160 and 240 W of electron incident beam power, respectively. Two stage neutron production with an electron to photon natural tungsten converter and a photon to neutron Be-9 converter are equal or less efficient than one stage tungsten converter only. There is a low neutron separation energy of Be-9 and a small cross section for the photonuclear reaction gamma(Be-9,Be-8*)n in comparison to photonuclear cross section in all tungsten isotopes for the photon energy range in and below resonance region. Results of the neutron generator modeling performed with the Fluka Monte-Carlo code are presented in this article.
引用
收藏
页码:169 / 173
页数:5
相关论文
共 50 条
  • [31] MONTE-CARLO SIMULATIONS FOR THE EQUATION OF STATE OF ATHERMAL LINEAR ALKANES
    YETHIRAJ, A
    JOURNAL OF CHEMICAL PHYSICS, 1995, 102 (17): : 6874 - 6880
  • [32] Monte-Carlo simulations of a high-resolution neutron TOF instrument
    Bernhardt, P
    Demmel, F
    Magerl, A
    PHYSICA B, 2000, 276 : 114 - 115
  • [33] MONTE-CARLO SIMULATIONS OF NEUTRON-TRANSPORT IN A LINAC RADIOTHERAPY ROOM
    AGOSTEO, S
    PARA, AF
    SILARI, M
    TORRESIN, A
    TOSI, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 72 (01): : 84 - 90
  • [34] POROSITY LOGGING USING EPITHERMAL NEUTRON LIFETIME - MONTE-CARLO SIMULATIONS
    WILSON, RD
    STROMSWOLD, DC
    MILLS, WR
    COOK, TK
    NUCLEAR GEOPHYSICS, 1989, 3 (04): : 323 - 334
  • [35] Characterisation of a megavoltage linear accelerator Bremsstrahlung by means of Monte Carlo simulations
    Valente, M.
    Malano, F.
    Perez, P.
    Castro, N.
    Carrasco, F.
    X-RAY SPECTROMETRY, 2010, 39 (06) : 384 - 390
  • [36] INFLUENCE OF HEAD COVER ON THE NEUTRON DOSE EQUIVALENT IN MONTE CARLO SIMULATIONS OF HIGH ENERGY MEDICAL LINEAR ACCELERATOR
    Brkic, Hrvoje
    Kasabasic, Mladen
    Ivkovic, Ana
    Agic, Dejan
    Krpan, Ivana
    Faj, Dario
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2018, 33 (02): : 217 - 222
  • [37] USE OF MONTE-CARLO GENERATED PENCIL BEAM DATA IN ELECTRON DOSIMETRY
    RILEY, RJ
    MOHAN, R
    LAUGHLIN, JS
    GOODMAN, M
    KARPOVSKY, A
    GABRIEL, T
    MEDICAL PHYSICS, 1981, 8 (05) : 741 - 741
  • [38] Calculation of the neutron source's neutron flux spectra in coal with Monte-Carlo simulation
    Chen, Boxian
    Zhang, Hongqiang
    Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 1997, 17 (01): : 24 - 27
  • [39] MONTE-CARLO STUDY OF ACCELERATOR HEAD SCATTER
    CHANEY, EL
    CULLIP, TJ
    GABRIEL, TA
    MEDICAL PHYSICS, 1994, 21 (09) : 1383 - 1390
  • [40] MONTE-CARLO SIMULATIONS OF LINEAR AND CYCLIC CHAINS ON CUBIC AND QUADRATIC LATTICES
    REITER, J
    MACROMOLECULES, 1990, 23 (16) : 3811 - 3816