One of the critical points, when the reliable operation of water-cooled generator is concerned, is the mechanical integrity of stator windings. The resonance of stator winding will occur when the intrinsic frequency of each stator winding equals or closes to excitation frequency, 120Hz, due to an electromagnetic force which occurs always during the normal operation. This resonance may cause the leak of cooling water and / or the life reduction of generator stator due to the high cycle fatigue crack. This paper describes the modeling of generator stator end windings for analysis of the winding vibration behaviors. The result of the analysis has a good agreement with that of field test. A mechanical diagnostic method is also suggested and applied to 500MW water-cooled generator stator in order to evaluate the mechanical integrity of stator end windings in power plant. It was found that the vibration characteristics of poor windings in terms of resonance possibility could be improved through the blocking of end windings.
引用
收藏
页码:75 / 80
页数:6
相关论文
共 50 条
  • [1] Prognostics for Stator Windings of Water-Cooled Generator Against Water Absorption
    Jang, Beom Chan
    Youn, Byeng D.
    Kim, Hee Soo
    Bae, Yong Chae
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2015, 39 (06) : 625 - 629
  • [2] ASSESSING THE INTEGRITY OF GENERATOR STATOR END WINDINGS
    Ellis, Matthew
    Kraijesteijn, Joop
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING AND THE ASME 2012 POWER CONFERENCE - 2012, VOL 1, 2012, : 387 - 392
  • [3] Health Diagnostics of Water-Cooled Power Generator Stator Windings Using a Directional Mahalanobis Distance (DMD)
    Park, Kyung Min
    Youn, Byeng D.
    Yoon, Joung Taek
    Hu, Chao
    Kim, Hee Soo
    Bae, Yong Chae
    2013 IEEE INTERNATIONAL CONFERENCE ON PROGNOSTICS AND HEALTH MANAGEMENT, 2013,
  • [4] Analysis of Leak and Water Absorption Test Results for Water-Cooled Generator Stator Windings
    Kim, Hee-Soo
    Bae, Yong-Chae
    Lee, Wook-Ryun
    Lee, Doo-Young
    Kim, Hee-Dong
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2012, 7 (02) : 230 - 235
  • [5] Corrosion and Deposits in Water-Cooled Generator Stator Windings: Overview of Water Cooling of Generators
    Svoboda, Robert
    Blecken, Wolf-Dietrich
    POWERPLANT CHEMISTRY, 2018, 20 (05): : 290 - 294
  • [6] Experience on the periodic wet bar diagnosis of water-cooled generator stator windings
    Kim, Hee-Soo
    Bae, Yong-Chae
    BALTICA VIII: LIFE MANAGEMENT AND MAINTENANCE FOR POWER PLANTS, VOL 2, 2010, 265 : 253 - 269
  • [7] An Experimental Study on the Dryness Judgement Criterion for Water-cooled Generator Stator Windings
    Kim, Hee Soo
    Bae, Yong Chae
    Lee, Wook Ryun
    Lee, Doo Young
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2010, 34 (02) : 137 - 143
  • [8] Problems with modern air-cooled generator stator windings
    Tucker, S
    Milsom, J
    Griffith, G
    Stone, G
    INTERNATIONAL CONFERENCE ON POWER STATION MAINTENANCE 2000, 2000, 2000 (07): : 137 - 144
  • [9] Corrosion and Deposits in Water-Cooled Generator Stator Windings: Part 1: Behaviour of Copper
    Svoboda, Robert
    POWERPLANT CHEMISTRY, 2018, 20 (05): : 297 - 309
  • [10] Corrosion and Deposits in Water-Cooled Generator Stator Windings: Part 2: Detection of Flow Restrictions
    Svoboda, Robert
    Chetwynd, Russell
    POWERPLANT CHEMISTRY, 2018, 20 (06): : 326 - 336