N-D Point Cloud Registration for Intensity Normalization on Magnetic Resonance Images

被引:2
|
作者
Gao, Yuan [1 ,3 ]
Pan, Jiawei [2 ]
Guo, Yi [1 ,3 ]
Yu, Jinhua [1 ,3 ]
Zhang, Jun [2 ]
Geng, Daoying [2 ]
Wang, Yuanyuan [1 ,3 ]
机构
[1] Fudan Univ, Dept Elect Engn, Shanghai, Peoples R China
[2] Fudan Univ, Huashan Hosp, Dept Radiol, Shanghai, Peoples R China
[3] Key Lab Med Imaging Comp & Comp Assisted Interven, Shanghai, Peoples R China
来源
VIPIMAGE 2017 | 2018年 / 27卷
关键词
Magnetic resonance imaging; Intensity normalization; Sub-region intensity; Point cloud; Spline interpolation; HUMAN BRAIN; B-SPLINES; STANDARDIZATION; SCALE; ATLAS;
D O I
10.1007/978-3-319-68195-5_13
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Magnetic resonance imaging (MRI) is a non-invasive inspection method widely used in clinical environment. Therefore, this is one of the research hotspots in computer-aided medical diagnosis. However, due to the disparities in imaging protocols as well as the magnetic field strength, the variation of intensity in different MRI scanners results in performance reduction in automatic image analysis and diagnosis procedure. This paper aims at forming a non-rigid intensity transforming function to normalize the intensities of MRI images. The transforming function is obtained from an N-Dimensional (N-D) point cloud, which is formed of weighted sub-region intensity distribution. The proposed method consists of five parts, including pre-alignment, sub-region standard intensity estimation, weighted N-D point cloud generation, spline-based transforming function interpolation as well as final image normalization. This novel method could not only avoid the intensity distortion caused by inconsistent bright-dark relation between tissues in target images and reference images, but also reduce the dependence on the accuracy of multi-modality MRI image registration. The experiments were conducted on a database of 10 volunteers scanned with two different MRI scanners and three modalities. We show that the peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) were both enhanced comparing with the histogram-matching method as well as the joint histogram registration method. It can be concluded that the intensities of MRI images acquired from different scanners could be normalized well using the proposed method so that multi-center/multi-machine correlation could be easily carried out in MRI image acquisition and analysis.
引用
收藏
页码:121 / 130
页数:10
相关论文
共 50 条
  • [41] Hierarchical Optimization of 3D Point Cloud Registration
    Liu, Huikai
    Zhang, Yue
    Lei, Linjian
    Xie, Hui
    Li, Yan
    Sun, Shengli
    SENSORS, 2020, 20 (23) : 1 - 20
  • [42] 4D Point Cloud Registration for Tumor Vascular Networks Monitoring from Ultrasensitive Doppler Images
    Cohen, E.
    Deffieux, T.
    Demene, C.
    Cohen, L. D.
    Tanter, M.
    COMPUTER METHODS, IMAGING AND VISUALIZATION IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 36 : 437 - 456
  • [43] Fast 3-D object pose normalization for point cloud
    Ruchay, Alexey
    Gladkov, Alexey
    Chelabiev, Ramin
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XLIV, 2021, 11842
  • [44] Hybrid3D: learning 3D hybrid features with point clouds and multi-view images for point cloud registration
    Bangbang YANG
    Zhaoyang HUANG
    Yijin LI
    Han ZHOU
    Hongsheng LI
    Guofeng ZHANG
    Hujun BAO
    Science China(Information Sciences), 2023, 66 (07) : 77 - 93
  • [45] Hybrid3D: learning 3D hybrid features with point clouds and multi-view images for point cloud registration
    Yang, Bangbang
    Huang, Zhaoyang
    Li, Yijin
    Zhou, Han
    Li, Hongsheng
    Zhang, Guofeng
    Bao, Hujun
    SCIENCE CHINA-INFORMATION SCIENCES, 2023, 66 (07)
  • [46] Normalization of functional magnetic resonance images by classified cerebrospinal fluid cluster
    Hu, Zhenghui
    Shi, Pengcheng
    18TH INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION, VOL 3, PROCEEDINGS, 2006, : 938 - +
  • [47] Robust Intensity Standardization in Brain Magnetic Resonance Images
    De Nunzio, Giorgio
    Cataldo, Rosella
    Carla, Alessandra
    JOURNAL OF DIGITAL IMAGING, 2015, 28 (06) : 727 - 737
  • [48] Robust Intensity Standardization in Brain Magnetic Resonance Images
    Giorgio De Nunzio
    Rosella Cataldo
    Alessandra Carlà
    Journal of Digital Imaging, 2015, 28 : 727 - 737
  • [49] A parametric intensity-based 3D image registration method for magnetic resonance imaging
    Huajun Song
    Peihua Qiu
    Signal, Image and Video Processing, 2017, 11 : 455 - 462
  • [50] A parametric intensity-based 3D image registration method for magnetic resonance imaging
    Song, Huajun
    Qiu, Peihua
    SIGNAL IMAGE AND VIDEO PROCESSING, 2017, 11 (03) : 455 - 462