Empirical Prediction of Carbon-Steel Degradation Rates on an Offshore Oil and Gas Facility: Predicting CO2 Erosion-Corrosion Pipeline Failures Before They Occur

被引:16
作者
Barker, R. [1 ]
Hu, X.
Neville, A. [2 ]
Cushnaghan, S. [3 ]
机构
[1] Univ Leeds, Sch Mech Engn, Inst Engn Thermofluids Surfaces & Interfaces, Leeds LS2 9JT, W Yorkshire, England
[2] Univ Leeds, Leeds LS2 9JT, W Yorkshire, England
[3] Shell UK Ltd, London, England
来源
SPE JOURNAL | 2014年 / 19卷 / 03期
关键词
DIOXIDE CORROSION; MECHANISTIC MODEL; JET IMPINGEMENT; MILD-STEEL;
D O I
10.2118/163143-PA
中图分类号
TE [石油、天然气工业];
学科分类号
0820 ;
摘要
Various sections of carbon-steel pipework removed from an offshore facility were found to have experienced severe degradation, partly attributed to an insufficient inhibitor dose rate, as discussed in a previous case study (Hu et al. 2011b). An investigation was conducted to compare the predictive capability of an empirical model generated with data from a submerged-impinging-jet laboratory apparatus. The model was assessed in its ability to determine the rate of thickness loss for carbon-steel pipework subjected to a CO2-containing erosion-corrosion environment, reviewing to what extent the prediction agrees with inspection data. The investigation considers whether the developed tool could have predicted pipework failures on the facility, comparing it with the degradation rate calculated from a leak that occurred within the past 2 years. The program of experiments set out to create a means of prediction with the material-loss data from submerged-impinging-jet tests over a range of conditions replicating those within the line. Information pertaining to the temperature, production rate, and sand loading was collated for the offshore facility. These data were used along with mass-loss results to predict the degradation rate on the asset as a function of time over a 5-year period. This in turn was used to predict the total thickness loss of the pipework wall as a function of time. Consideration was also given to the current use of inhibition (10 ppm Inhibitor A) as well as the predicted thickness losses as a function of time had a candidate inhibitor been used instead (50 ppm Inhibitor B). Limitations of the model are presented, along with suggestions for ways to develop the model further.
引用
收藏
页码:425 / 436
页数:12
相关论文
共 34 条
  • [11] CORRELATION OF STEEL CORROSION IN PIPE-FLOW WITH JET IMPINGEMENT AND ROTATING CYLINDER TESTS
    EFIRD, KD
    WRIGHT, EJ
    BOROS, JA
    HAILEY, TG
    [J]. CORROSION, 1993, 49 (12) : 992 - 1003
  • [12] An integrated methodology for predicting material wear rates due to erosion
    Gnanavelu, A.
    Kapur, N.
    Neville, A.
    Flores, J. F.
    [J]. WEAR, 2009, 267 (11) : 1935 - 1944
  • [13] Halvorsen A.M., 1999, CORROSION 99
  • [14] Hassani S., 2012, CORROSION 2012
  • [15] Hecht A., 1997, TIME FLIGHT DIFFRACT
  • [16] Hu X., 2008, CORROSION 2008
  • [17] Assessing the effect of corrosion inhibitor on erosion-corrosion of API-5L-X65 in multi-phase jet impingement conditions
    Hu, Xinming
    Alzawai, Khaled
    Gnanavelu, Abinesh
    Neville, Anne
    Wang, Chun
    Crossland, Alan
    Martin, John
    [J]. WEAR, 2011, 271 (9-10) : 1432 - 1437
  • [18] Case study on erosion-corrosion degradation of pipework located on an offshore oil and gas facility
    Hu, Xinming
    Barker, Richard
    Neville, Anne
    Gnanavelu, Abinesh
    [J]. WEAR, 2011, 271 (9-10) : 1295 - 1301
  • [19] Keating A., 2000, CORROSION 2000
  • [20] Carbon dioxide corrosion in oil and gas production - A compendium
    Kermani, MB
    Morshed, A
    [J]. CORROSION, 2003, 59 (08) : 659 - 683