Calibrated CFD simulation to evaluate thermal comfort in a highly-glazed naturally ventilated room

被引:50
作者
Hajdukiewicz, Magdalena [1 ,2 ,3 ]
Geron, Marco [1 ,2 ,3 ]
Keane, Marcus M. [1 ,2 ,3 ]
机构
[1] IRUSE, Galway, Ireland
[2] Natl Univ Ireland Galway, Dept Civil Engn, Galway, Ireland
[3] Natl Univ Ireland Galway, Ryan Inst, Galway, Ireland
基金
爱尔兰科学基金会;
关键词
CFD; Measurement; Indoor environment; Natural ventilation; Calibration; Thermal comfort; INDOOR ENVIRONMENTS; AIR; BUILDINGS; ENERGY;
D O I
10.1016/j.buildenv.2013.08.020
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Natural ventilation is a sustainable solution to maintaining healthy and comfortable environmental conditions in buildings. However, the effective design, construction and operation of naturally ventilated buildings require a good understanding of complex airflow patterns caused by the buoyancy and wind effects. The work presented in this article employed a 3D computational fluid dynamics (CFD) analysis in order to investigate environmental conditions and thermal comfort of the occupants of a highly-glazed naturally ventilated meeting room. This analysis was facilitated by the real-time field measurements performed in an operating building, and previously developed formal calibration methodology for reliable CFD models of indoor environments. Since, creating an accurate CFD model of an occupied space in a real-life scenario requires a high level of CFD expertise, trusted experimental data and an ability to interpret model input parameters; the calibration methodology guided towards a robust and reliable CFD model of the indoor environment. This calibrated CFD model was then used to. investigate indoor environmental conditions and to evaluate thermal comfort indices for the occupants of the room. Thermal comfort expresses occupants' satisfaction with thermal environment in buildings by defining the range of indoor thermal environmental conditions acceptable to a majority of occupants. In this study, the thermal comfort analysis, supported by both field measurements and CFD simulation results, confirmed a satisfactory and optimal room operation in terms of thermal environment for the investigated real-life scenario. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:73 / 89
页数:17
相关论文
共 37 条
  • [1] AIAA, 1998, Guide for the verification and validation of computational fluid dynamics simulations
  • [2] Saving energy by using underfloor-air-distribution (UFAD) system in commercial buildings
    Alajmi, Ali
    El-Amer, Wid
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (08) : 1637 - 1642
  • [3] [Anonymous], 1998, PERCEIVED BARRIERS N
  • [4] [Anonymous], 2003, 20030408 AIAA
  • [5] [Anonymous], 2005, ERGONOMICS THERMAL E
  • [6] [Anonymous], 2001, HDB FUNDAMENTALS
  • [7] ANSI/ASHRAE, 2004, THERM ENV COND HUM O
  • [8] Arup North America, 2011, NAT VENT EN SAV CAL
  • [9] Berglund L.G., 1987, ASHRAE Transactions, V93, P497
  • [10] Evaluation of thermal comfort using combined CFD and experimentation study in a test room equipped with a cooling ceiling
    Catalina, Tiberiu
    Virgone, Joseph
    Kuznik, Frederic