The efficacy of cylindrical titanium mesh cage for the reconstruction of a critical-size canine segmental femoral diaphyseal defect

被引:85
|
作者
Lindsey, Ronald W.
Gugala, Zbigniew
Milne, Edward
Sun, Michael
Gannon, Francis H.
Latta, Loren L.
机构
[1] Baylor Coll Med, Dept Orthopaed Surg, Houston, TX 77030 USA
[2] Univ Miami, Miami, FL 33152 USA
[3] Univ Chicago, Dept Orthopaed Surg, Chicago, IL 60637 USA
[4] Armed Forces Inst Pathol, Dept Bone Pathol, Washington, DC 20306 USA
关键词
titanium mesh cage; canine; femoral diaphyseal defect;
D O I
10.1002/jor.20154
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The authors developed a novel technique for the reconstruction of large segmental long bone defects using a cylindrical titanium mesh cage (CTMC). Although the initial clinical reports have been favorable, the CTMC technique has yet to be validated in a clinically relevant large animal model, which is the purpose of this study. Under general anesthesia, a unilateral, 3-cm mid-diaphyseal segmental defect was created in the femur of an adult canine. The defect reconstruction technique consisted of a CTMC that was packed and surrounded with a standard volume of morselized canine cancellous allograft and canine demineralized bone matrix. The limb was stabilized with a reamed titanium intramedullary nail. Animals were distributed into four experimental groups: in Groups A 13, and C (six dogs each), defects were CTMC reconstructed, and the animals euthanized at 6, 12, and 18 weeks, respectively; in Group D (three dogs), the same defect reconstruction was performed but without a CTMC, and the animals were euthanized at 18 weeks. The femurs were harvested and analyzed by gross inspection, plain radiography, computed tomography (CT), and single photon emission computed tomography (SPECT). The femurs were mechanically tested in axial torsion to failure; two randomly selected defect femurs from each group were analyzed histologically. Groups A, B, and C specimens gross inspection, plain radiography, and CT, demonstrated bony restoration of the defect, and SPECT confirmed sustained biological activity throughout the CTMC. Compared to the contralateral femur, the 6-, 12-, and 18-week mean defect torsional stiffness was 44.4, 45.7, and 72.5%, respectively; the mean torsional strength was 51.0, 73.6, and 83.4%, respectively. Histology documented new bone formation spanning the defect. Conversely, Group D specimens (without CTMC) demonstrated no meaningful bone formation, biologic activity, or mechanical integrity at 18 weeks. The CTMC technique facilitated healing of a canine femur segmental defect model, while the same technique without a cage did not. The CTMC technique may be a viable alternative for the treatment of segmental long bone defects. (c) 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:1438 / 1453
页数:16
相关论文
共 8 条
  • [1] Reconstruction of critical size segmental femoral diaphyseal defects of New Zealand rabbits by using combined titanium mesh cage and induced membrane technique
    Kaya, Onur
    Mirioglu, Akif
    Ozkan, Cenk
    Bicer, Omer Sunkar
    Deveci, Mehmet Ali
    Tekin, Mustafa
    Ates, Kivilcim Eren
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (03) : 629 - 637
  • [2] Reconstruction of critical size segmental femoral diaphyseal defects of New Zealand rabbits by using combined titanium mesh cage and induced membrane technique
    Onur Kaya
    Akif Mirioglu
    Cenk Ozkan
    Omer Sunkar Bicer
    Mehmet Ali Deveci
    Mustafa Tekin
    Kivilcim Eren Ates
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 629 - 637
  • [3] Management of a long segmental defect at the proximal meta-diaphyseal junction of the tibia using a cylindrical titanium mesh cage
    Ostermann, PAW
    Haase, N
    Rübberdt, A
    Wich, M
    Ekkernkamp, A
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (08) : 597 - 601
  • [4] The cylindrical titanium mesh cage for treatment of a long bone segmental defect: Description of a new technique and report of two cases
    Cobos, JA
    Lindsey, RW
    Gugala, Z
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (01) : 54 - 59
  • [5] Surgical management of large segmental femoral and radial bone defects in a dog Through use of a cylindrical titanium mesh cage and a cancellous bone graft
    Segal, U.
    Shani, J.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2010, 23 (01) : 66 - 70
  • [6] The stability of impacted morsellized bone grafts in a metal cage under dynamic loaded conditions: an in vitro reconstruction of a segmental diaphyseal bone defect
    Bullens, Pieter H. J.
    Schreuder, Bart H. W.
    Malefijt, Maarten C. de Waal
    Veth, Rene P. H.
    Buma, Pieter
    Verdonschot, Nico
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (05) : 575 - 581
  • [7] Posterior-only Hemivertebra Resection With Anterior Structural Reconstruction With Titanium Mesh Cage and Short Segmental Fusion for the Treatment of Congenital Scoliokyphosis The Indications and Preliminary Results
    Wang, Shengru
    Zhang, Jianguo
    Qiu, Guixing
    Li, Shugang
    Zhang, Yanbin
    Yang, Yang
    Weng, Xisheng
    SPINE, 2017, 42 (22) : 1687 - 1692
  • [8] Comparison of clinical efficacy of 3D-printed artificial vertebral body and conventional titanium mesh cage in spinal reconstruction after total en bloc spondylectomy for spinal tumors: a systematic review and meta-analysis
    Dong, Mingjie
    Gao, Yingjie
    Fan, Hao
    Wang, Yushan
    Lv, Jia
    Bai, Junjun
    Shao, Pengfei
    Gao, Yu
    Lv, Zhi
    Feng, Yi
    FRONTIERS IN ONCOLOGY, 2024, 14