Molecularly imprinted polymer-based, solid-phase extraction followed by liquid chromatographic determination of lacosamide in rat plasma

被引:3
|
作者
Rao, R. Nageswara [1 ]
Sravan, B. [1 ]
Reddy, Ch. Krishna [2 ]
Meena, S. [3 ]
Prashamsa, J. [4 ]
Spoorthy, P. [5 ]
机构
[1] Indian Inst Chem Technol, Div Analyt Chem, Hyderabad, Andhra Pradesh, India
[2] KM Coll Pharm, Madurai, Tamil Nadu, India
[3] Acharya & BM Reddy Coll Pharm, Bangalore, India
[4] Kakatiya Univ, Univ Coll Pharmaceut Sci, Warangal, Andhra Pradesh, India
[5] Gokaraju Rangaraju Coll Pharm, Hyderabad, Andhra Pradesh, India
关键词
PRECLINICAL PHARMACOKINETICS; ANTIEPILEPTIC DRUG; QUANTIFICATION;
D O I
10.1039/c3ay42186d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel sample clean-up technique, water-compatible, molecularly imprinted, solid-phase extraction (MISPE), combined with high-performance liquid chromatography (HPLC), was developed and validated for selective extraction and determination of lacosamide in rat plasma. The molecularly imprinted polymer (MIP) was synthesized using methacrylic acid as a functional monomer, ethylene glycol dimethacrylate as a cross-linker, chloroform as a porogen, and lacosamide as a template. Its efficacy as a selective sorbent in solid-phase extraction of lacosamide and the effects of various porogenic solvents, pH, crosslinker, and amount of monomer were studied and optimized. The recovery was >98% with a detection limit of 0.03 mu g mL(-1) over a linear range of 0.1-100 mu g mL(-1).
引用
收藏
页码:3101 / 3107
页数:7
相关论文
共 50 条
  • [41] Selective analysis of Nadifloxacin in human plasma samples using a molecularly imprinted polymer-based solid-phase extraction proceeded by UPLC-DAD analysis
    Tarek, Mohamed
    Elzanfaly, Eman S.
    Amer, Sawsan M.
    Wagdy, Hebatallah A.
    MICROCHEMICAL JOURNAL, 2020, 158
  • [42] Inside-Needle Extraction Method Based on Molecularly Imprinted Polymer for Solid-Phase Dynamic Extraction and Preconcentration of Triazine Herbicides Followed by GC-FID Determination
    Djozan, Djavanshir
    Farajzadeh, Mir Ali
    Sorouraddin, Saeed Mohammad
    Baheri, Tahmineh
    Norouzi, Jamal
    CHROMATOGRAPHIA, 2012, 75 (3-4) : 139 - 148
  • [43] A Novel Molecularly Imprinted Polymer for the Solid-Phase Extraction of Tanshinones from Serum
    He, Hongliang
    Li, Hong
    Gao, Yankun
    Chen, Dong
    Shi, Liying
    Peng, Jin
    Du, Shuhu
    Chen, Lina
    ANALYTICAL LETTERS, 2015, 48 (01) : 47 - 60
  • [44] Molecularly imprinted polymer microspheres for solid-phase extraction of chloramphenicol residues in foods
    Shi, Xizhi
    Wu, Aibo
    Zheng, Sulian
    Li, Rongxiu
    Zhang, Dabing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2): : 24 - 30
  • [45] Selective Solid-Phase Extraction of Meropenem from Human Blood Plasma Using a Molecularly Imprinted Polymer
    Sirumapea, Lasmaryna
    Zulfikar, Mohammad Ali
    Amran, Muhammad Bachri
    Alni, Anita
    INDONESIAN JOURNAL OF CHEMISTRY, 2021, 21 (05) : 1167 - 1179
  • [46] Solid-phase extraction of S-(-)-amlodipine from plasma with a uniformly sized molecularly imprinted polymer
    Luo, Kaixia
    Liu, Meng
    Fu, Qiang
    Amut, Elijan
    Zeng, Aiguo
    Chang, Chun
    JOURNAL OF APPLIED POLYMER SCIENCE, 2012, 125 (05) : 3524 - 3531
  • [47] Synthesis and application of molecularly imprinted polymer on selective solid-phase extraction for the determination of monosulfuron residue in soil
    Dong, XC
    Wang, N
    Wang, SL
    Zhang, XW
    Fan, ZJ
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1057 (1-2) : 13 - 19
  • [48] Computer-aided design of magnetic molecularly imprinted polymer nanoparticles for solid-phase extraction and determination of levetiracetam in human plasma
    Attallah, Olivia A.
    Al-Ghobashy, Medhat A.
    Ayoub, Ahmed Taha
    Tuszynski, Jack Adam
    Nebsen, Marianne
    RSC ADVANCES, 2018, 8 (26) : 14280 - 14292
  • [49] Molecularly Imprinted Polymer Solid Phase Extraction followed by High-Performance Liquid Chromatography as an Efficient and Sensitive Technique for Determination of Meropenem in Human Plasma and Urine
    Amlashi, Hamoon Sami
    Daryasari, Ameneh Porgham
    Soleimani, Mojtaba
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 2019, 72 : 32 - 39
  • [50] Application of dual-template molecularly imprinted polymer-based solid phase extraction for determination of phenothiazines and benzodiazepines in swine feed
    Xia, Wan Qiu
    Cui, Peng Lei
    Wang, Geng Nan
    Liu, Jing
    Wang, Jian Ping
    ANALYTICAL METHODS, 2018, 10 (25) : 3001 - 3010