Integration of ozone, UV/H2O2 and GAC in a multi-barrier treatment for secondary effluent polishing: Reuse parameters and micropollutants removal

被引:11
作者
Granzoto, Mariana R. [1 ]
Seabra, Ivna [1 ]
Malvestiti, Jacqueline A. [1 ]
Cristale, Joyce [1 ]
Dantas, Renato F. [1 ]
机构
[1] Univ Estadual Campinas, Sch Technol, UNICAMP, Paschoal Marmo 1888, BR-13484332 Limeira, SP, Brazil
关键词
Ozonation; Micropollutants; Advanced oxidation processes; Multibarrier; Costs; ADVANCED OXIDATION PROCESSES; WATER TREATMENT-PLANT; WASTE-WATER; ACTIVATED CARBON; FLAME RETARDANTS; TRANSFORMATION PRODUCTS; DRINKING-WATER; PLASTICIZERS; ELIMINATION; DEGRADATION;
D O I
10.1016/j.scitotenv.2020.143498
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Current studies tend to combine different advanced treatment technologies to reduce costs and increase efficiency. The objective of thisworkwas to assess the combination of ozonation and UV/H2O2 with activated carbon adsorption for the removal of effluent quality parameters and micropollutants fromsecondary effluent samples. The experiments were carried out using the following configurations: O-3+ GAC+ O-3 (1); O-3+ GAC+ UV/H2O2 (2); UV/H2O2+ GAC+ O-3 (3); UV/H2O2+ GAC+ UV/H2O2 (4). Configurations 1, 3 and 4 were themost efficient for organic matter removal, while configuration 1 had the lowest cost on laboratory scale. An additional ultra-filtration membrane unit (UF) was tested at the end of configuration 1, which was optimized in terms of ozone doses for the removal of three organophosphate micropollutants in ultrapure water (TNBP, TCIPP and TPHP at 10 mu g L-1). The best cost-effective configuration of this treatment train was the one using 1 mg L-1 of ozone before and after GAC, which achieved around 100% of micropollutants abatement. The role of each treatment to the final micropollutant removal was also discussed, being the first ozone treatment responsible for about 15% removal of the mixture of contaminants, while GAC was responsible for an additional 80% removal. The complete treatment train reached almost 100% of contaminants removal (under detection limit of the method), as well as added security to the system. The achieved results were also compared to international reuse legislations, proving that the combination of O-3 and GACwas an interesting option to achieve enough quality for some reuse purposes. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 45 条
  • [1] Elimination of organophosphate ester flame retardants and plasticizers in drinking water purification
    Andresen, J
    Bester, K
    [J]. WATER RESEARCH, 2006, 40 (03) : 621 - 629
  • [2] ANEEL (Brazilian Electricity Regulatory Agency), 2020, RANK EL TAR WWW DOC
  • [3] [Anonymous], 2012, DEVELOPMENT, V26, P252
  • [4] [Anonymous], 2018, WAC RECLAIMED WATER
  • [5] APHA/AWWA/WEF, 2012, Standard methods, V541
  • [6] Comparison of various advanced oxidation processes and chemical treatment methods for COD and color removal from a polyester and acetate fiber dyeing effluent
    Azbar, N
    Yonar, T
    Kestioglu, K
    [J]. CHEMOSPHERE, 2004, 55 (01) : 35 - 43
  • [7] Bell K., 2016, WATER ONLINE
  • [8] Organophosphate esters by GC-MS: An optimized method for aquatic risk assessment
    Cristale, Joyce
    Oliveira Santos, Izabela
    Fagnani, Enelton
    [J]. JOURNAL OF SEPARATION SCIENCE, 2020, 43 (04) : 748 - 755
  • [9] Can activated sludge treatments and advanced oxidation processes remove organophosphorus flame retardants?
    Cristale, Joyce
    Ramos, Dayana D.
    Dantas, Renato F.
    Machulek Junior, Amilcar
    Lacorte, Silvia
    Sans, Carme
    Esplugas, Santiago
    [J]. ENVIRONMENTAL RESEARCH, 2016, 144 : 11 - 18
  • [10] A coagulation-powdered activated carbon-ultrafiltration - Multiple barrier approach for removing toxins from two Australian cyanobacterial blooms
    Dixon, Mike B.
    Richard, Yann
    Ho, Lionel
    Chow, Christopher W. K.
    O'Neill, Brian K.
    Newcombe, Gayle
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2011, 186 (2-3) : 1553 - 1559