Energy and exergy analysis of integrated system of ammonia-water Kalina-Rankine cycle

被引:44
作者
Chen, Yaping [1 ]
Guo, Zhanwei [1 ]
Wu, Jiafeng [1 ]
Zhang, Zhi [1 ,2 ]
Hua, Junye [3 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Key Lab Energy Thermal Convers & Control, Minist Educ, Nanjing 210096, Jiangsu, Peoples R China
[2] Anhui Ind Univ, Maanshan 243002, Anhui, Peoples R China
[3] Nanjing Normal Univ, Nanjing 210042, Jiangsu, Peoples R China
关键词
Ammonia-water; Kalina cycle; Rankine cycle; Exergy analysis; Energy analysis; Cogeneration of power and heating water; THERMODYNAMIC ANALYSIS; POWER; GENERATION; RECOVERY; HEAT;
D O I
10.1016/j.energy.2015.07.038
中图分类号
O414.1 [热力学];
学科分类号
摘要
The integrated system of AWKRC (ammonia-water Kalina-Rankine cycle) is a novel cycle operated on MC (Kalina cycle) for power generation in non-heating seasons and on AWRC (ammonia-water Rankine cycle) for cogeneration of power and heating water in winter. The influences of inlet temperatures of both heat resource and cooling water on system efficiencies were analyzed based on the first law and the second law of thermodynamics. The calculation is based on following conditions that the heat resource temperature keeps 300 degrees C, the cooling water temperature for the KC or AWRC is respectively 25 degrees C or 15 degrees C; and the temperatures of heating water and backwater are respectively 90 degrees C and 40 degrees C. The results show that the evaluation indexes of the power recovery efficiency and the exergy efficiency of KC were respectively 18.2% and 41.9%, while the composite power recovery efficiency and the composite exergy efficiency of AWRC are respectively 21.1% and 43.0% accounting both power and equivalent power of cogenerated heating capacity, including 54.5% heating recovery ratio or 12.4% heating water exergy efficiency. The inventory flow diagrams of both energy and exergy gains and losses of the components operating on KC or AWRC are also demonstrated. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2028 / 2037
页数:10
相关论文
共 30 条
  • [1] RECOVERY AND UTILIZATION OF WASTE HEAT
    ALRABGHI, OM
    BEIRUTTY, M
    AKYURT, M
    NAJJAR, Y
    ALP, T
    [J]. HEAT RECOVERY SYSTEMS & CHP, 1993, 13 (05): : 463 - 470
  • [2] Heat recovery from Diesel engines: A thermodynamic comparison between Kalina and ORC cycles
    Bombarda, Paola
    Invernizzi, Costante M.
    Pietra, Claudio
    [J]. APPLIED THERMAL ENGINEERING, 2010, 30 (2-3) : 212 - 219
  • [3] Chen Y. P., 1997, THERM POWER GENERAT, V47, P20
  • [4] Chen YP, 1989, J SE U, V19, P52
  • [5] Second law assessment of binary plants generating power from low-temperature geothermal fluids
    DiPippo, R
    [J]. GEOTHERMICS, 2004, 33 (05) : 565 - 586
  • [6] Fluid selection for the Organic Rankine Cycle (ORC) in biomass power and heat plants
    Drescher, Ulli
    Brueggemann, Dieter
    [J]. APPLIED THERMAL ENGINEERING, 2007, 27 (01) : 223 - 228
  • [7] Possibilities of electricity generation in the Republic of Croatia by means of geothermal energy
    Guzovic, Z.
    Loncar, D.
    Ferdelji, N.
    [J]. ENERGY, 2010, 35 (08) : 3429 - 3440
  • [8] The performance of the kalina cycle system 11(KCS-11) with low-temperature heat sources
    Hettiarachchi, H. D. Madhawa
    Golubovic, Mihailo
    Worek, William M.
    Ikegami, Yasuyuki
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2007, 129 (03): : 243 - 247
  • [9] Thermodynamic analysis of simplified dual-pressure ammonia-water absorption power cycle
    Hua Jun-ye
    Chen Ya-ping
    Liu Hua-jin
    Wu Jia-feng
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2012, 19 (03) : 797 - 802
  • [10] Thermal performance of a modified ammonia-water power cycle for reclaiming mid/low-grade waste heat
    Hua Junye
    Chen Yaping
    Wu Jiafeng
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 85 : 453 - 459