Reliability and validity of two fitness tracker devices in the laboratory and home environment for older community-dwelling people

被引:49
作者
Burton, Elissa [1 ]
Hill, Keith D. [1 ]
Lautenschlager, Nicola T. [2 ,3 ]
Thogersen-Ntoumani, Cecilie [4 ]
Lewin, Gill [5 ]
Boyle, Eileen [1 ]
Howie, Erin [6 ]
机构
[1] Curtin Univ, Sch Physiotherapy & Exercise Sci, Perth, WA, Australia
[2] Univ Melbourne, Dept Psychiat, Acad Unit Psychiat Old Age, Melbourne, Vic, Australia
[3] NorthWestern Mental Hlth, Melbourne, Vic, Australia
[4] Curtin Univ, Sch Psychol, Perth, WA, Australia
[5] Curtin Univ, Sch Nursing Midwifery & Paramed, Perth, WA, Australia
[6] Univ Arkansas, Dept Hlth Human Performance & Recreat, Fayetteville, AR 72701 USA
关键词
Ageing; Activity tracker; Accelerometer; MEASURING PHYSICAL-ACTIVITY; FREE-LIVING CONDITIONS; ACTIVITY MONITORS; SEDENTARY BEHAVIOR; ACTIVITY SCALE; ELDERLY PASE; VALIDATION; ADULTS; REHABILITATION; ACCURACY;
D O I
10.1186/s12877-018-0793-4
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background: Two-thirds of older Australians are sedentary. Fitness trackers have been popular with younger people and may encourage older adults to become more active. Older adults may have different gait patterns and as such it is important to establish whether fitness trackers are valid and reliable for this population. The aim of the study was to test the reliability and validity of two fitness trackers (Fitbit Flex and ChargeHR) by step count when worn by older adults. Reliability and validity were tested in two conditions: 1) in the laboratory using a two-minute-walk-test (2MWT) and 2) in a free-living environment Methods: Two 2MWTs were completed while wearing the fitness trackers. Participants were videoed during each test. Participants were then given one fitness tracker and a GENEactiv accelerometer to wear at home for 14-days. Results: Thirty-one participants completed two 2MWTs and 30 completed the free-living procedure. Intra Class Correlation's of the fitness trackers with direct observation of steps (criterion validity) was high (ICC:0.86,95%CI:0.76,0. 93). However, both fitness trackers underestimated steps. Excellent test-retest reliability (ICC >= 0.75) was found between the two 2MWTs for each device, particularly the ChargeHR devices. Good strength of agreement was found for total distance and steps (fitness tracker) and moderate-to-vigorous physical activity (GENEactiv) for the free-living environment (Spearman Rho's 0.78 and 0.74 respectively). Conclusion: Reliability and validity of the Flex and ChargeHR when worn by older adults is good, however both devices underestimated step count within the laboratory environment. These fitness trackers appear suitable for consumer use and promoting physical activity for older adults.
引用
收藏
页数:12
相关论文
共 36 条
[11]  
Cicchetti D. V., 1994, Psychol Assessment, V6, P284, DOI [DOI 10.1037/1040-3590.6.4.284, 10.1037/1040-3590.6.4.284]
[12]   Clinical Utility of the 2-Minute Walk Test for Older Adults Living in Long-Term Care [J].
Connelly, D. M. ;
Thomas, B. K. ;
Cliffe, S. J. ;
Perry, W. M. ;
Smith, R. E. .
PHYSIOTHERAPY CANADA, 2009, 61 (02) :78-87
[13]  
de Man M., 2016, Sensoria: A Journal of Mind, Brain Culture, V12, P40, DOI DOI 10.7790/SA.V12I2.442
[14]   Validation of the Fitbit One® for physical activity measurement at an upper torso attachment site [J].
Diaz K.M. ;
Krupka D.J. ;
Chang M.J. ;
Shaffer J.A. ;
Ma Y. ;
Goldsmith J. ;
Schwartz J.E. ;
Davidson K.W. .
BMC Research Notes, 9 (1)
[15]   Validation of the GENEA Accelerometer [J].
Esliger, Dale W. ;
Rowlands, Ann V. ;
Hurst, Tina L. ;
Catt, Michael ;
Murray, Peter ;
Eston, Roger G. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (06) :1085-1093
[16]   Physical activity and sedentary behavior patterns using accelerometry from a national sample of United States adults [J].
Evenson, Kelly R. ;
Wen, Fang ;
Metzger, Jesse S. ;
Herring, Amy H. .
INTERNATIONAL JOURNAL OF BEHAVIORAL NUTRITION AND PHYSICAL ACTIVITY, 2015, 12
[17]   Validation of Consumer-Based Hip and Wrist Activity Monitors in Older Adults With Varied Ambulatory Abilities [J].
Floegel, Theresa A. ;
Florez-Pregonero, Alberto ;
Hekler, Eric B. ;
Buman, Matthew P. .
JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2017, 72 (02) :229-236
[18]   Accuracy of 2 Activity Monitors in Detecting Steps in People With Stroke and Traumatic Brain Injury [J].
Fulk, George D. ;
Combs, Stephanie A. ;
Danks, Kelly A. ;
Nirider, Coby D. ;
Raja, Bhavana ;
Reisman, Darcy S. .
PHYSICAL THERAPY, 2014, 94 (02) :222-229
[19]   Comparison of wrist-worn and hip-worn activity monitors under free living conditions [J].
Hargens, Trent A. ;
Deyarmin, Kayla N. ;
Snyder, Kelsey M. ;
Mihalik, Allison G. ;
Sharpe, Lauren E. .
Journal of Medical Engineering and Technology, 2017, 41 (03) :200-207
[20]   Increasing Trend of Fatal Falls in Older Adults in the United States, 1992 to 2005: Coding Practice or Reporting Quality? [J].
Kharrazi, Rebekah J. ;
Nash, Denis ;
Mielenz, Thelma J. .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2015, 63 (09) :1913-1917