Reliability and validity of two fitness tracker devices in the laboratory and home environment for older community-dwelling people

被引:49
作者
Burton, Elissa [1 ]
Hill, Keith D. [1 ]
Lautenschlager, Nicola T. [2 ,3 ]
Thogersen-Ntoumani, Cecilie [4 ]
Lewin, Gill [5 ]
Boyle, Eileen [1 ]
Howie, Erin [6 ]
机构
[1] Curtin Univ, Sch Physiotherapy & Exercise Sci, Perth, WA, Australia
[2] Univ Melbourne, Dept Psychiat, Acad Unit Psychiat Old Age, Melbourne, Vic, Australia
[3] NorthWestern Mental Hlth, Melbourne, Vic, Australia
[4] Curtin Univ, Sch Psychol, Perth, WA, Australia
[5] Curtin Univ, Sch Nursing Midwifery & Paramed, Perth, WA, Australia
[6] Univ Arkansas, Dept Hlth Human Performance & Recreat, Fayetteville, AR 72701 USA
关键词
Ageing; Activity tracker; Accelerometer; MEASURING PHYSICAL-ACTIVITY; FREE-LIVING CONDITIONS; ACTIVITY MONITORS; SEDENTARY BEHAVIOR; ACTIVITY SCALE; ELDERLY PASE; VALIDATION; ADULTS; REHABILITATION; ACCURACY;
D O I
10.1186/s12877-018-0793-4
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background: Two-thirds of older Australians are sedentary. Fitness trackers have been popular with younger people and may encourage older adults to become more active. Older adults may have different gait patterns and as such it is important to establish whether fitness trackers are valid and reliable for this population. The aim of the study was to test the reliability and validity of two fitness trackers (Fitbit Flex and ChargeHR) by step count when worn by older adults. Reliability and validity were tested in two conditions: 1) in the laboratory using a two-minute-walk-test (2MWT) and 2) in a free-living environment Methods: Two 2MWTs were completed while wearing the fitness trackers. Participants were videoed during each test. Participants were then given one fitness tracker and a GENEactiv accelerometer to wear at home for 14-days. Results: Thirty-one participants completed two 2MWTs and 30 completed the free-living procedure. Intra Class Correlation's of the fitness trackers with direct observation of steps (criterion validity) was high (ICC:0.86,95%CI:0.76,0. 93). However, both fitness trackers underestimated steps. Excellent test-retest reliability (ICC >= 0.75) was found between the two 2MWTs for each device, particularly the ChargeHR devices. Good strength of agreement was found for total distance and steps (fitness tracker) and moderate-to-vigorous physical activity (GENEactiv) for the free-living environment (Spearman Rho's 0.78 and 0.74 respectively). Conclusion: Reliability and validity of the Flex and ChargeHR when worn by older adults is good, however both devices underestimated step count within the laboratory environment. These fitness trackers appear suitable for consumer use and promoting physical activity for older adults.
引用
收藏
页数:12
相关论文
共 36 条
[1]   Validation of Fitbit-Flex as a measure of free-living physical activity in a community-based phase III cardiac rehabilitation population [J].
Alharbi, Muaddi ;
Bauman, Adrian ;
Neubeck, Lis ;
Gallagher, Robyn .
EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2016, 23 (14) :1476-1485
[2]  
ALTMAN DG, 1991, PRACTICAL STAT MED R, P398
[3]  
Australian Bureau of Statistics, 4156 0 55 001 PERSP
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Lack of Exercise Is a Major Cause of Chronic Diseases [J].
Booth, Frank W. ;
Roberts, Christian K. ;
Laye, Matthew J. .
COMPREHENSIVE PHYSIOLOGY, 2012, 2 (02) :1143-1211
[6]   Concurrent Validity of Wearable Activity Trackers Under Free-Living Conditions [J].
Brooke, Skyler M. ;
An, Hyun-Sung ;
Kang, Seoung-Ki ;
Noble, John M. ;
Berg, Kris E. ;
Lee, Jung-Min .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (04) :1097-1106
[7]   2-MINUTE, 6-MINUTE, AND 12-MINUTE WALKING TESTS IN RESPIRATORY-DISEASE [J].
BUTLAND, RJA ;
PANG, J ;
GROSS, ER ;
WOODCOCK, AA ;
GEDDES, DM .
BRITISH MEDICAL JOURNAL, 1982, 284 (6329) :1607-1608
[8]   Measuring physical activity and sedentary behaviour at work: A review [J].
Castillo-Retamal, Marcelo ;
Hinckson, Erica A. .
WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2011, 40 (04) :345-357
[9]   Accuracy of Wristband Activity Monitors during Ambulation and Activities [J].
Chen, Ming-De ;
Kuo, Chang-Chih ;
Pellegrini, Christine A. ;
Hsu, Miao-Ju .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (10) :1942-1949
[10]   Comparison of wrist-worn Fitbit Flex and waist-worn ActiGraph for measuring steps in free-living adults [J].
Chu, Anne H. Y. ;
Ng, Sheryl H. X. ;
Paknezhad, Mahsa ;
Gauterin, Alvaro ;
Koh, David ;
Brown, Michael S. ;
Muller-Riemenschneider, Falk .
PLOS ONE, 2017, 12 (02)