Seismic experiment on blind-bolted joint in concrete-filled double steel tubular structure

被引:9
作者
Zhang, Yu-Fen [1 ]
Jia, Hong-Xin [1 ]
Cao, Sheng-Xi [2 ]
Demoha, Krushar [3 ]
机构
[1] Hebei Univ Technol, Sch Civil & Transportat Engn, Tianjin 300401, Peoples R China
[2] Northern Engn Design Res Inst Co, Shijiazhuang 050011, Hebei, Peoples R China
[3] Univ Auckland, Dept Mech Engn, Auckland 1142, New Zealand
基金
美国国家科学基金会;
关键词
CFDST column; Blind bolts; T-plate; Bearing capacity; Inner tube; TENSILE BEHAVIOR; COMPOSITE JOINTS; COLUMN; CONNECTIONS; SQUARE;
D O I
10.1016/j.jcsr.2020.106304
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this study, blind-bolted joints were designed for use between steel beams and concrete-filled double steel tubular (CFDST) columns to utilize the structural advantages offered by double steel tubes. Six joint specimens were tested under a constant axial load and lateral cyclic load for a CFDST column. The seismic behaviors of these blind-bolted joints were estimated in terms of the hysteretic curves, ductility, and energy dissipation. The effects of a T-plate section type and steel beam-type on the semi-rigid joints were studied. The test results showed that the failure of the joints began with the yielding of the T-plates, and that the final failure mode was plastic deformation at the steel beam ends. The obtained hysteretic curves were complete, and the energy dissipation ability of the bolted joint was strong. The bearing capacity and energy dissipation of ribbed joints were higher than those of unribbed joints. Based on a steel volume comparison, the installation of stiffening ribs proved to be considerably more effective than the thickening of the T-plate flanges. The strain response of the inner tube in each CFDST column was also estimated. It was concluded that the blind-bolted joints exhibit excellent deformation capacities and structural internal force redistributions. The results of this experimental research could be helpful for the application of blind-bolted joints in fabricated CFDST structures. (C) 2020 Published by Elsevier Ltd.
引用
收藏
页数:10
相关论文
共 29 条
  • [1] Tensile behaviour of anchored blind bolts in concrete filled square hollow sections
    Agheshlui, Hossein
    Goldsworthy, Helen
    Gad, Emad
    Fernando, Saman
    [J]. MATERIALS AND STRUCTURES, 2016, 49 (04) : 1511 - 1525
  • [2] [Anonymous], 1999, 50581999 DLT
  • [3] [Anonymous], 2017, GB 50017-2017
  • [4] [Anonymous], 1992, ATC-24
  • [5] Behaviour of bolted connections in concrete-filled steel tubular beam-column joints
    Beena, Kumari
    Naveen, Kwatra
    Shruti, Sharma
    [J]. STEEL AND COMPOSITE STRUCTURES, 2017, 25 (04) : 443 - 456
  • [6] Cai S.H., 2003, Modern steel tube confined concrete structures
  • [7] Experimental assessment of the behaviour of bolted T-stub connections made up of welded plates
    Coelho, AMG
    Bijlaard, FSK
    Gresnigt, N
    da Silva, LS
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (02) : 269 - 311
  • [8] Prefabricated connection for steel beam and concrete-filled steel tube column
    Ding, Chenting
    Pan, Xuebei
    Bai, Yu
    Shi, Gang
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 162
  • [9] Seismic evaluation and calculation models of CFDST column blind bolted to composite beam joints with partial shear interaction
    Guo, Lei
    Wang, Jingfeng
    Wang, Wanqian
    Duan, Mengjun
    [J]. ENGINEERING STRUCTURES, 2019, 196
  • [10] Experimental investigation and analytical modelling of blind bolted flush or extended end plate connections to circular CFDST columns
    Guo, Lei
    Wang, Jingfeng
    Wu, Shuncheng
    Zhong, Liping
    [J]. ENGINEERING STRUCTURES, 2019, 192 : 233 - 253