Paper-capillary spray for direct mass spectrometry analysis of biofluid samples

被引:42
|
作者
Ren, Yue [1 ]
Chiang, Spencer [1 ]
Zhang, Wenpeng [1 ]
Wang, Xiao [1 ]
Lin, Ziqing [1 ]
Ouyang, Zheng [1 ,2 ,3 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[3] Purdue Univ, Dept Elect & Comp Engn, W Lafayette, IN 47907 USA
基金
美国国家卫生研究院;
关键词
Bioanalyticalmethods; Mass spectrometry; Drug monitoring; Drug screening; NANO-ELECTROSPRAY IONIZATION; QUANTITATIVE-ANALYSIS; ATMOSPHERIC-PRESSURE; PROBE ELECTROSPRAY; AMBIENT CONDITIONS; THERAPEUTIC DRUGS; OPEN-AIR; BLOOD; MS; GENERATION;
D O I
10.1007/s00216-015-9129-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Paper spray has been developed as an ambient ionization method for direct analysis of biological samples using mass spectrometry. While distinct advantages of paper spray have been demonstrated, especially for quantitative analysis and design of disposable sample cartridges, the need for improvement has also been recognized, especially for the use with miniature mass spectrometers. In this study, we made an improvement to the sampling and ionization by adding a capillary emitter to the paper substrate to produce a paper-capillary spray, which has been shown to have significant, positive impact on the sensitivity and reproducibility for direct mass spectrometry analysis. The paper-capillary devices were fabricated and the effects of the geometry, the treatment of the capillary emitters, as well as the sample disposition methods were characterized. The method's analytical performance was also characterized for analysis of therapeutic drugs in blood samples. Quantitation of cotinine in blood using a commercial triple quadrupole and sitagliptin (JanuviaA (R)) in blood using a desktop Mini 12 ion trap mass spectrometer was also demonstrated.
引用
收藏
页码:1385 / 1390
页数:6
相关论文
共 50 条
  • [1] Paper-capillary spray for direct mass spectrometry analysis of biofluid samples
    Yue Ren
    Spencer Chiang
    Wenpeng Zhang
    Xiao Wang
    Ziqing Lin
    Zheng Ouyang
    Analytical and Bioanalytical Chemistry, 2016, 408 : 1385 - 1390
  • [2] Direct Biofluid Analysis Using Hydrophobic Paper Spray Mass Spectrometry
    Damon, Deidre E.
    Davis, Kathryn M.
    Moreira, Camila R.
    Capone, Patricia
    Cruttenden, Riley
    Badu-Tawiah, Abraham K.
    ANALYTICAL CHEMISTRY, 2016, 88 (03) : 1878 - 1884
  • [3] Direct Quantitative Analysis of Nicotine Alkaloids from Biofluid Samples using Paper Spray Mass Spectrometry
    Wang, He
    Ren, Yue
    McLuckey, Morgan N.
    Manicke, Nicholas E.
    Park, Jonghyuck
    Zheng, Lingxing
    Shi, Riyi
    Cooks, R. Graham
    Ouyang, Zheng
    ANALYTICAL CHEMISTRY, 2013, 85 (23) : 11540 - 11544
  • [4] Ionization Suppression and Recovery in Direct Biofluid Analysis Using Paper Spray Mass Spectrometry
    Vega, Carolina
    Spence, Corina
    Zhang, Chengsen
    Bills, Brandon J.
    Manicke, Nicholas E.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2016, 27 (04) : 726 - 734
  • [5] Portable paper-in-tip spray ionization for the direct mass spectrometric analysis of target analytes in biofluid samples
    Lu, Fangfang
    Zheng, Yajun
    Zhang, Yuan
    Ma, Qiang
    Zhang, Zhiping
    ANALYTICAL METHODS, 2022, 14 (03) : 222 - 227
  • [6] Zero volt paper spray ionization mass spectrometry for direct analysis of samples on filter paper substrate
    Motoyama, Akira
    Kihara, Keishi
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (20) : 1905 - 1916
  • [7] Direct Analysis of Biological Tissue by Paper Spray Mass Spectrometry
    Wang, He
    Manicke, Nicholas E.
    Yang, Qian
    Zheng, Lingxing
    Shi, Riyi
    Cooks, R. Graham
    Zheng Ouyang
    ANALYTICAL CHEMISTRY, 2011, 83 (04) : 1197 - 1201
  • [8] Direct analysis of herbicides by paper spray ionization mass spectrometry
    Reeber, Steven L.
    Gadi, Sneha
    Huang, Sung-Ben
    Glish, Gary L.
    ANALYTICAL METHODS, 2015, 7 (23) : 9808 - 9816
  • [9] High-Precision Quantitation of Biofluid Samples Using Direct Mass Spectrometry Analysis
    Zhang, Wenpeng
    Ren, Yue
    Lin, Ziqing
    Ouyang, Zheng
    ANALYTICAL CHEMISTRY, 2019, 91 (11) : 6986 - 6990
  • [10] Conductive Polymer Spray Ionization Mass Spectrometry for Biofluid Analysis
    Song, Xiaowei
    Chen, Hao
    Zare, Richard N.
    ANALYTICAL CHEMISTRY, 2018, 90 (21) : 12878 - 12885