An Improved Trap Design for Decoupling Multinuclear RF Coils

被引:53
作者
Meyerspeer, Martin [1 ,2 ,3 ]
Roig, Eulalia Seres [1 ,4 ]
Gruetter, Rolf [1 ,4 ,5 ]
Magill, Arthur W. [1 ,4 ]
机构
[1] Ecole Polytech Fed Lausanne, LIFMET, Lausanne, Switzerland
[2] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
[3] Med Univ Vienna, MR Ctr Excellence, Vienna, Austria
[4] Univ Lausanne, Dept Radiol, Lausanne, Switzerland
[5] Univ Geneva, Dept Radiol, Geneva, Switzerland
基金
奥地利科学基金会;
关键词
X-nucleus; RF coils; C-13; trap; dual-resonant; MAGNETIC-RESONANCE; SKELETAL-MUSCLE; C-13; NMR; 4; TESLA; SPECTROSCOPY; HUMANS; QUANTITATION; SODIUM; BRAIN; PROBE;
D O I
10.1002/mrm.24931
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Multinuclear magnetic resonance spectroscopy and imaging require a radiofrequency probe capable of transmitting and receiving at the proton and non-proton frequencies. To minimize coupling between probe elements tuned to different frequencies, LC (inductor-capacitor) traps blocking current at the H-1 frequency can be inserted in non-proton elements. This work compares LC traps with LCC traps, a modified design incorporating an additional capacitor, enabling control of the trap reactance at the low frequency while maintaining H-1 blocking. Methods: Losses introduced by both types of trap were analysed using circuit models. Radiofrequency coils incorporating a series of LC and LCC traps were then built and evaluated at the bench. LCC trap performance was then confirmed using H-1 and C-13 measurements in a 7T human scanner. Results: LC and LCC traps both effectively block interaction between non-proton and proton coils at the proton frequency. LCC traps were found to introduce a sensitivity reduction of 5 +/- 2%, which was less than half of that caused by LC traps. Conclusion: Sensitivity of non-proton coils is critical. The improved trap design, incorporating one extra capacitor, significantly reduces losses introduced by the trap in the nonproton coil. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:584 / 590
页数:7
相关论文
共 24 条
[1]   A half-volume coil for efficient proton decoupling in humans at 4 Tesla [J].
Adriany, G ;
Gruetter, R .
JOURNAL OF MAGNETIC RESONANCE, 1997, 125 (01) :178-184
[2]   Practical design of a 4 Tesla double-tuned RF surface coil for interleaved 1H and 23Na MRI of rat brain [J].
Alecci, M. ;
Romanzetti, S. ;
Kaffanke, J. ;
Celik, A. ;
Wegener, H. P. ;
Shah, N. J. .
JOURNAL OF MAGNETIC RESONANCE, 2006, 181 (02) :203-211
[3]   Evaluation of extra- and intracellular apparent diffusion coefficient of sodium in rat skeletal muscle: Effects of prolonged ischemia [J].
Babsky, Andriy M. ;
Topper, Stephen ;
Zhang, Hong ;
Gao, Yong ;
James, Judy R. ;
Hekmatyar, Shahryar K. ;
Bansal, Navin .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) :485-491
[4]   PROTON-DECOUPLED, OVERHAUSER-ENHANCED, SPATIALLY LOCALIZED C-13 SPECTROSCOPY IN HUMANS [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ROEMER, PB ;
MUELLER, OM .
MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (03) :348-363
[5]   NON-INVASIVE, NON-DESTRUCTIVE APPROACHES TO CELL BIOENERGETICS [J].
CHANCE, B ;
ELEFF, S ;
LEIGH, JS .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1980, 77 (12) :7430-7434
[6]   MULTIPLE CONTROLS OF OXIDATIVE-METABOLISM IN LIVING TISSUES AS STUDIED BY PHOSPHORUS MAGNETIC-RESONANCE [J].
CHANCE, B ;
LEIGH, JS ;
KENT, J ;
MCCULLY, K ;
NIOKA, S ;
CLARK, BJ ;
MARIS, JM ;
GRAHAM, T .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (24) :9458-9462
[7]   Trap Design for Insertable Second-Nuclei Radiofrequency Coils for Magnetic Resonance Imaging and Spectroscopy [J].
Dabirzadeh, Arash ;
McDougall, Mary Preston .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2009, 35B (03) :121-132
[8]   An Insertable P-31 RF coil for Dual-frequency Magnetic Resonance Imaging & Spectroscopy [J].
Dabirzadeh, Arash ;
Chang, Chieh-Wei ;
McDougall, Mary P. .
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, :2036-+
[9]   QUICK MEASUREMENT OF NMR-COIL SENSITIVITY WITH A DUAL-LOOP PROBE [J].
DARRASSE, L ;
KASSAB, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (07) :1841-1844
[10]  
de Graaf RA., 1998, VIVO NMR SPECTROSCOP, P508