Retrospective cohort trial protocol of screw fixation compared with hemiarthroplasty for displaced femoral neck fractures in elderly patients

被引:4
作者
Qin, Boquan [1 ]
Cui, Linxian [2 ]
Ren, Yi [1 ]
Zhang, Hui [1 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Orthopaed Surg, Chengdu 610041, Sichuan, Peoples R China
[2] Univ Elect Sci & Technol China, Sichuan Prov Peoples Hosp, Dept Cardiol, Chengdu, Sichuan, Peoples R China
关键词
displaced femoral neck fractures; hemiarthroplasty; protocol; revision; screw fixation; OUTCOMES; YOUNGER;
D O I
10.1097/MD.0000000000022397
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: There is limited evidence for the evaluation of the efficacy and safety of the hemiarthroplasty versus screw fixation in elderly patients with the displaced femoral neck fractures. Our current investigation aimed at assessing the complications, functional outcome, and revision rate of the patients (over 65 years old) who received internal fixation or hemiarthroplasty via a same senior surgeon. Methods: A retrospective study was conducted on elderly patients with displaced femoral neck fractures from May 2014 to February 2018. The current study was carried out at our hospital and it was approved through our institutional review committee of West China Hospital. Inclusion criteria were as follows: the patients were 65 years or older, this is the anesthesia grade. The higher grade of the patients,the greater risk of surgery. level I-III, and the patients with displaced intracapsular fractures of the femoral neck, with the radiographic and clinical follow-up of 12 months or more. The major outcome was the revision rate between the 2 groups. And the secondary outcomes contained the life quality and functional outcome detected via utilizing the interview-administered and self-administered questionnaires, length of hospital stay, surgery time, and hip-related complications (such as hip dislocation, loosening or breakage of implant, wound problems, infection, osteolysis, neurovascular injury, and bone nonunion). Results: It was assumed that hemiarthroplasty would result in fewer revisions or complications and better functional scores in comparison with internal fixation technique.
引用
收藏
页数:3
相关论文
共 20 条
[1]   Low bone density and high morbidity in patients between 55 and 70 years with displaced femoral neck fractures: a case-control study of 50 patients vs 150 normal controls [J].
Bartels, Stefan ;
Gjertsen, Jan-Erik ;
Frihagen, Frede ;
Rogmark, Cecilia ;
Utvag, Stein Erik .
BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
[2]   Predictors of early failure of the cannulated screw system in patients, 65 years and older, with non-displaced femoral neck fractures [J].
Biz, Carlo ;
Tagliapietra, Jacopo ;
Zonta, Filippo ;
Belluzzi, Elisa ;
Bragazzi, Nicola Luigi ;
Ruggieri, Pietro .
AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2020, 32 (03) :505-513
[3]   Bipolar versus monopolar hemiarthroplasty for displaced femur neck fractures: a meta-analysis study [J].
Filippo, Migliorini ;
Driessen, Arne ;
Colarossi, Giorgia ;
Quack, Valentin ;
Tingart, Markus ;
Eschweiler, Jorg .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (03) :401-410
[4]   Hemiarthroplasty for Displaced Femoral Neck Fractures in the Elderly Has a Low Conversion Rate [J].
Grosso, Matthew J. ;
Danoff, Jonathan R. ;
Murtaugh, Taylor S. ;
Trofa, David P. ;
Sawires, Andrew N. ;
Macaulay, William B. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (01) :150-154
[5]   Intraoperative periprosthetic femur fracture during bipolar hemiarthroplasty for displaced femoral neck fractures [J].
Hong, Choon Chiet ;
Nashi, Nazrul ;
Tan, Jiong Hao ;
Manohara, Ruben ;
Lee, Wei Ting ;
Murphy, Diarmuid Paul .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (09) :1189-1198
[6]   Unipolar versus bipolar hemiarthroplasty for displaced femoral neck fractures: A pooled analysis of 30,250 participants data [J].
Imam, Mohamed A. ;
Shehata, Mohamed ;
Abdallah, Ahmed R. ;
Ahmed, Hussien ;
Kader, Nardeen ;
Ernstbrunner, Lukas ;
Narvani, Ali A. ;
Kambouroglou, Gregoris ;
Mcnamara, Iain ;
Sallam, Asser A. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (10) :1694-1708
[7]  
Iorio R, 2001, CLIN ORTHOP RELAT R, P229
[8]   Displaced femoral neck fractures in patients 60 years of age or younger: results of internal fixation with the dynamic locking blade plate [J].
Kalsbeek, J. H. ;
van Walsum, A. D. P. ;
Vroemen, J. P. A. M. ;
Janzing, H. M. J. ;
Winkelhorst, J. T. ;
Bertelink, B. P. ;
Roerdink, W. H. .
BONE & JOINT JOURNAL, 2018, 100B (04) :443-449
[9]   Cemented versus Uncemented Hemiarthroplasty for Displaced Femoral Neck Fractures: 5-year Followup of a Randomized Trial [J].
Langslet, Ellen ;
Frihagen, Frede ;
Opland, Vidar ;
Madsen, Jan Erik ;
Nordsletten, Lars ;
Figved, Wender .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (04) :1291-1299
[10]   Clinical Outcomes of Gap Balancing vs Measured Resection in Total Knee Arthroplasty: A Systematic Review and Meta-Analysis Involving 2259 Subjects [J].
Li, Shuxiang ;
Luo, Xiaomin ;
Wang, Peng ;
Sun, Han ;
Wang, Kun ;
Sun, Xiaoliang .
JOURNAL OF ARTHROPLASTY, 2018, 33 (08) :2684-2693