Independent evaluations of IMRT through the use of an anthropomorphic phantom

被引:54
作者
Ibbott, Geoffrey S. [1 ]
Molineu, Andrea [1 ]
Followill, David S. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Radiol Phys Ctr, Houston, TX 77030 USA
关键词
D O I
10.1177/153303460600500504
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intensity-modulated radiation therapy (IMRT) has gained rapid and wide-spread acceptance in the radiation oncology community for its ability to create dose distributions that conform to the convoluted shapes of many tumors. It is a complicated treatment technique, for which quality assurance procedures are correspondingly complicated and labor intensive. Several of the cooperative cancer study groups that conduct clinical trials under the auspices of the National Cancer Institute have required participating institutions to seek credentialing before enrolling patients in trials involving IMRT. The Radiological Physics Center has conducted such credentialing programs through the use of anthropomorphic phantoms that evaluate the planning and delivery of IMRT The experience obtained through the irradiation of the phantoms by a number of institutions demonstrates that institutions vary significantly in their ability to deliver doses and dose distributions that agree with their own treatment plans.
引用
收藏
页码:481 / 487
页数:7
相关论文
共 41 条
[1]  
AGUIRRE JF, 2002, STANDARDS CODES PRAC, V2, P191
[2]  
Alvarez P, 2004, MED PHYS, V31, P1732
[3]  
BALTER P, 1999, MED PHYS, V26, P1164
[4]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[5]   Intensity-modulated radiotherapy: Current status and issues of interest [J].
Boyer, AL ;
Butler, EB ;
DiPetrillo, TA ;
Engler, MJ ;
Fraass, B ;
Grant, W ;
Ling, CC ;
Low, DA ;
Mackie, TR ;
Mohan, R ;
Purdy, JA ;
Roach, M ;
Rosenman, JG ;
Verhey, LJ ;
Wong, JW ;
Cumberlin, RL ;
Stone, H ;
Palta, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04) :880-914
[6]   Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate [J].
Burman, C ;
Chui, CS ;
Kutcher, G ;
Leibel, S ;
Zelefsky, M ;
LoSasso, T ;
Spirou, S ;
Wu, QW ;
Yang, J ;
Stein, J ;
Mohan, R ;
Fuks, Z ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04) :863-873
[7]   Verification of lung dose in an anthropomorphic phantom calculated by the collapsed cone convolution method [J].
Butson, MJ ;
Elferink, R ;
Cheung, T ;
Yu, PKN ;
Stokes, M ;
Quach, KY ;
Metcalfe, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :N143-N149
[8]   Dosimetric considerations for validation of a sequential IMRT process with a commercial treatment planning system [J].
Cadman, P ;
Bassalow, R ;
Sidhu, NPS ;
Ibbott, G ;
Nelson, A .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (16) :3001-3010
[9]   Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium [J].
Carrasco, P ;
Jornet, N ;
Duch, MA ;
Weber, L ;
Ginjaume, M ;
Eudaldo, T ;
Jurado, D ;
Ruiz, A ;
Ribas, M .
MEDICAL PHYSICS, 2004, 31 (10) :2899-2911
[10]   Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee [J].
Ezzell, GA ;
Galvin, JM ;
Low, D ;
Palta, JR ;
Rosen, I ;
Sharpe, MB ;
Xia, P ;
Xiao, Y ;
Xing, L ;
Yu, CX .
MEDICAL PHYSICS, 2003, 30 (08) :2089-2115