Calibration Method of Particle Counter for Clean Spaces

被引:0
|
作者
Wang Han [1 ]
Li Jie [1 ]
Xing Rongxin [1 ]
Zhao Zhao [1 ]
机构
[1] Chinese Elect Standardizat Inst, Beijing 100007, Peoples R China
来源
PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOL. 3 | 2008年
关键词
Optical particle counter; calibration; clean space;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, compared with the present calibration procedures performed by the metrology facilities and optical particle counter manufactures, the recommended calibration method of optical particle counters (OPC), which are operated on the principle of light scattering by individual particles and widely used in clean-room monitoring, air pollution control and laboratory aerosol studies is discussed. Based on referencing international standards and verified in more than several models of particle counters widely used in China, the calibration methods recommended here include inlet sample flow rate, repeatability, error of particle concentration and particle sizing accuracy.
引用
收藏
页码:1381 / 1384
页数:4
相关论文
共 50 条
  • [41] Sequential Calibration Method of Nonlinear Errors of PIGA on Counter-Rotating Platform Centrifuge
    Sun, Chuang
    Ren, Shun-Qing
    Zeng, Ming
    Wang, Chang-Hong
    Huo, Ru
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70 (70)
  • [42] LOW-COST TIME COUNTER FOR DIRECT FLOWMETER CALIBRATION BY SOAP FILM METHOD
    不详
    CONTROL AND INSTRUMENTATION, 1977, 9 (02): : 11 - 11
  • [43] Application of voxel phantoms and Monte Carlo method to whole-body counter calibration
    Kinase, S.
    Takagi, S.
    Noguchi, H.
    Saito, K.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 189 - 193
  • [44] CALIBRATION CIRCUIT FOR COUNTER-CHRONOGRAPHS
    KHAN, SA
    INDIAN JOURNAL OF TECHNOLOGY, 1965, 3 (10): : 335 - +
  • [45] ENERGY CALIBRATION OF A LIQUID SCINTILLATION COUNTER
    HORROCKS, DL
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1973, 24 (01): : 49 - 51
  • [46] Applying ISO methods to counter calibration
    Gecsey, Joe
    Cleanroom Technology, 2011, 19 (12): : 18 - 19
  • [47] INTRINSIC CALIBRATION OF THE POLLAK COUNTER - A REVISION
    SINCLAIR, D
    AEROSOL SCIENCE AND TECHNOLOGY, 1983, 2 (02) : 235 - 235
  • [48] CALIBRATION OF A SLIT COLLIMATED SCINTILLATION COUNTER
    CONCANNON, JP
    SUMMERS, RE
    WILLIAMS, NS
    MOOERS, CV
    JOURNAL OF NUCLEAR MEDICINE, 1962, 3 (03) : 210 - 211
  • [49] The MEG timing counter calibration and performance
    De Gerone, M.
    Dussoni, S.
    Fratini, K.
    Gatti, F.
    Valle, R.
    Boca, G.
    Cattaneo, P. W.
    Rossella, M.
    Nardo, R.
    Papa, A.
    Signorelli, G.
    Cavoto, G.
    Piredda, G.
    Renga, F.
    Voena, C.
    Uchiyama, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 638 (01): : 41 - 46
  • [50] Neutron multiplicity counter design and calibration
    Gong, J. (gongjian@caep.ac.cn), 1600, Tsinghua University (54):