Model validation and case study on internally cooled/heated dehumidifier/regenerator of liquid desiccant systems

被引:75
作者
Yin, Yonggao [1 ]
Zhang, Xiaosong [1 ]
Peng, Donggen [1 ]
Li, Xiuwei [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid desiccant; Internally heated regenerator; Internally cooled dehumidifier; Optimal design; MASS-TRANSFER; HEAT; AIR; PERFORMANCE; FILM; REGENERATOR; ABSORPTION;
D O I
10.1016/j.ijthermalsci.2008.12.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
Traditional dehumidifiers and regenerators of liquid desiccant systems often use packed columns supporting adiabatic heat and mass transfer between air and liquid desiccant. As new-style equipment, internally-cooled dehumidifiers can improve dehumidification performance due to restraining temperature increase of the desiccant. Similar to internally-cooled dehumidifiers, an idea of internally heating is imitated to put forward internally-heated regenerators. The uniform mathematical model for an internally cooled dehumidifier and internally heated regenerator was presented and validated by comparison of computation results with experimental data in this study. The case study focused on the parameters distribution comparisons of the internally cooled/heated dehumidifier/regenerator with adiabatic ones and demonstrated coupled heat and mass transfer behavior. The results show that the internally-heated regenerator can produce higher regeneration efficiency than the adiabatic one to produce better energy efficiency and eliminate the dehumidification possibility which would happen in adiabatic regenerators. The internally-cooled dehumidifier can also provide better dehumidification performance comparing with the adiabatic one; however its benefit would be not as good as the internally-heated regenerator. In addition, effect of the width of the air channel on internally cooled/heated dehumidifier/regenerator was discussed and the results can help the optimal design of this kind of dehumidifiers and regenerators. (C) 2008 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:1664 / 1671
页数:8
相关论文
共 50 条
  • [31] Experimental analysis of dehumidification performance of an evaporative cooling-assisted internally cooled liquid desiccant dehumidifier
    Park, Joon-Young
    Kim, Beom-Jun
    Yoon, Soo-Yeol
    Byon, Yoo-Suk
    Jeong, Jae-Weon
    APPLIED ENERGY, 2019, 235 : 177 - 185
  • [32] Experimental and 4 NTU-Le heat and mass transfer model theoretical analysis based on a novel internally cooled liquid desiccant dehumidifier
    Zhang, Guangkai
    Tan, Jingjie
    Xie, Jingchao
    Du, Boyao
    Liu, Honggang
    Liu, Jiaping
    ENERGY, 2024, 313
  • [33] Parametric Study on an Air-heated Desiccant Solution Regenerator
    Yin, Yonggao
    Zhang, Xiaosong
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 756 - 765
  • [34] Heat and mass transfer model of cross flow liquid desiccant air dehumidifier/regenerator
    Liu, X. H.
    Jiang, Y.
    Qu, K. Y.
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (02) : 546 - 554
  • [35] Experimental study of internally cooled liquid desiccant dehumidification: Application in Hong Kong and intensive analysis of influencing factors
    Luo, Yimo
    Wang, Meng
    Yang, Hongxing
    Lu, Lin
    Peng, Jinqing
    BUILDING AND ENVIRONMENT, 2015, 93 : 210 - 220
  • [36] Energy consumption and optimization of internally cooled/heated liquid desiccant air-conditioning system: A case study in Hong Kong
    Qi, Ronghui
    Lu, Lin
    ENERGY, 2014, 73 : 801 - 808
  • [37] Optimization of NTUm allocation between dehumidifier and regenerator in liquid-desiccant air-conditioning system
    Guan, Bowen
    Liu, Xiaohua
    Zhang, Tao
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 127 : 250 - 259
  • [38] Heat and mass transfer in an adjacent internally-cooled membrane-based liquid desiccant dehumidifier (AIMLDD)
    Yang, Yu
    Yang, Minlin
    Huang, Weihao
    Huang, Si-Min
    Ye, Wei-Biao
    Hong, Yuxiang
    Qin, Frank G. F.
    Shao, Youyuan
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 3990 - 3997
  • [39] A Theoretical Model on Internally Cooled Liquid Desiccant Dehumidification and Cooling Processes
    Alan, S. W. L.
    Islam, M. R.
    Chua, K. J.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 1009 - 1014
  • [40] Implementation and validation of an artificial neural network for predicting the performance of a liquid desiccant dehumidifier
    Mohammad, Abdulrahman Th.
    Bin Mat, Sohif
    Sulaiman, M. Y.
    Sopian, K.
    Al-Abidi, Abduljalil A.
    ENERGY CONVERSION AND MANAGEMENT, 2013, 67 : 240 - 250