Evaluating Two Techniques on Removal of Fractured Rotary Nickel-Titanium Endodontic Instruments from Root Canals: An In Vitro Study

被引:31
作者
Alomairy, Khalid H. [1 ]
机构
[1] Karolinska Inst, Dept Endodontol, Inst Odontol, S-14151 Huddinge, Sweden
关键词
Instrument removal; operating microscope; separated instrument; ultrasonics; ULTRASONIC TECHNIQUE; CLINICAL-USE; SYSTEMS; EFFICIENCY; DEFECTS; FILES;
D O I
10.1016/j.joen.2008.12.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the ultrasonic technique (US) and instrument removal system (iRS) in removing fractured rotary nickel-titanium (NiTi) from root canals. A total of 30 extracted human molars with closed apices were collected. Profile .06 taper rotary endodontic instruments (Dentsply Maillefer, Ballaigues, Switzerland) 25-mm long and ISO size 25 were driven into the mesial canal to be fractured in the curve. Angles and radii of curvature were measured for all the canals with the fractured fragments, and then canals were classified into slight, moderate, and severe subgroups according to their curvature angles. Within each subgroup, teeth were randomly distributed into LIS or iRS according to measured angles and radii; a total of 15 canals were assigned to both US and iRS techniques. The overall success rate was 70% (n = 21). Less Curved canals and longer radii of curvature showed more success. The median time used for retrieval was 40 minutes using the US technique, whereas it was 55 minutes for iRS. The removal of fractured rotary NiTi endodontic instruments was more successful with less curved canals and longer radius of curvature above 4.4 mm. (J Endod 2009;35:559-562)
引用
收藏
页码:559 / 562
页数:4
相关论文
共 39 条
[31]   Complications associated with fractured file removal using an ultrasonic technique [J].
Souter, NJ ;
Messer, HH .
JOURNAL OF ENDODONTICS, 2005, 31 (06) :450-452
[32]   The impact of instrument fracture on outcome of endodontic treatment [J].
Spili, P ;
Parasbos, P ;
Messer, HH .
JOURNAL OF ENDODONTICS, 2005, 31 (12) :845-850
[33]  
Strindberg L.Z., 1956, ACTA ODONTOL SCAND, V14, P1
[34]   Probability of removing fractured instruments from root canals [J].
Suter, B ;
Lussi, A ;
Sequeira, P .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (02) :112-123
[35]   Evaluation of the efficiency of a new file removal system in comparison with two conventional systems [J].
Terauchi, Yoshitsugu ;
O'Leary, Le ;
Kikuchi, Izumi ;
Asanagi, Mami ;
Yoshioka, Takatomo ;
Kobayashi, Chihiro ;
Suda, Hideaki .
JOURNAL OF ENDODONTICS, 2007, 33 (05) :585-588
[36]   Removal of separated files from root canals with a new file-removal system: Case reports [J].
Terauchi, Yoshitsugu ;
O'Leary, Le ;
Suda, Hideaki .
JOURNAL OF ENDODONTICS, 2006, 32 (08) :789-797
[37]  
Torabinejad M., 2002, Principles and practice of endodontics, P310
[38]   A comparative study of root canal preparation using ProFile .04 and Lightspeed rotary Ni-Ti instruments [J].
Versümer, J ;
Hülsmann, M ;
Schäfers, F .
INTERNATIONAL ENDODONTIC JOURNAL, 2002, 35 (01) :37-46
[39]   Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: Clinical cases [J].
Ward, JR ;
Parashos, P ;
Messer, HH .