Comparison of repeatability of non-invasive and invasive urodynamics

被引:10
|
作者
van Mastrigt, R [1 ]
Chung, JWNCHF [1 ]
机构
[1] Erasmus MC, Dept Urol, Sector Furore, NL-3000 DR Rotterdam, Netherlands
关键词
difference plot; non-invasive; repeatability; reproducibility; urodynamics;
D O I
10.1002/nau.20043
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Aims: We have developed a method for the non-invasive measurement of urinary bladder pressure, and we apply this method in a longitudinal study of changes in bladder contractility in response to prostatic enlargement. In each volunteer in this study, we measure the bladder pressure twice. In the present study we have used this data to compare the repeatability of the non-invasive method to that of pressure-flow studies in a comparable population of patients. Methods: Difference plots were made of non-invasive bladder pressure measurements in 457 volunteers and of pressure-flow studies in a comparable population of 397 male patients. To compare the repeatability of two different methods for clinical measurement, the standard deviation of differences between repeated measurements in one individual needs to be normalised. Often a normalisation by dividing by the mean is done. We show that that normalisation may lead to erroneous results. We have normalised the standard deviations by dividing by the difference between the 97.5th and 2.5th percentile of the mean of the two observations in each subject. Results: Normalised repeatability of the non-invasive method was 0.15, that of the various parameters derived from the pressure-flow studies varied from 0.11 to 0.22. Conclusions: We conclude that the repeatability of the tested non-invasive urodynamic method is comparable to, or slightly better than, that of pressure-flow studies. We further conclude that normalising standard deviations of differences by dividing by the difference between the 97.5th and 2.5th percentile of the mean is a suitable method to compare the repeatability of different methods for clinical measurement. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:317 / 321
页数:5
相关论文
共 50 条
  • [21] Applied strategy for options of invasive and non-invasive sensors and instruments
    Yan, Zhang
    Xin, Liu
    Scopesi, Fabio
    Serra, Giovanni
    Sun, Jinwei
    Rolfe, Peter
    FIFTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, 2009, 7133
  • [22] Comparison of invasive and non-invasive cylindrical capacitive sensors for electrical measurements of different water solutions and mixtures
    Behzadi, G.
    Golnabi, H.
    SENSORS AND ACTUATORS A-PHYSICAL, 2011, 167 (02) : 359 - 366
  • [23] Predictability and limitations of non-invasive murine tonometry: Comparison of two devices
    Filippopoulos, Theodoros
    Matsubara, Akihisa
    Danias, John
    Huang, Wei
    Dobberfuhl, Adam
    Ren, Lizhen
    Mittag, Thomas
    Miller, Joan W.
    Grosskreutz, Cynthia L.
    EXPERIMENTAL EYE RESEARCH, 2006, 83 (01) : 194 - 201
  • [24] Comparison of Invasive and Non-invasive Estimation of [11C]PBR28 Binding in Non-human Primates
    Aceves-Serrano, Lucero
    Sossi, Vesna
    Doudet, Doris J.
    MOLECULAR IMAGING AND BIOLOGY, 2022, 24 (03) : 404 - 415
  • [25] Non-invasive Wireless Bio Sensing
    Arsenio, Artur
    Andrade, Joao
    Duarte, Andreia
    BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, BIOSTEC 2015, 2015, 574 : 93 - 109
  • [26] Non-invasive assessment of liver fibrosis
    Papastergiou, Vasilios
    Tsochatzis, Emmanuel
    Burroughs, Andrew K.
    ANNALS OF GASTROENTEROLOGY, 2012, 25 (03): : 218 - 231
  • [27] Non-invasive vesicoureteral reflux imaging
    Snow, Brent W.
    Taylor, Michael B.
    JOURNAL OF PEDIATRIC UROLOGY, 2010, 6 (06) : 543 - 549
  • [28] Non-invasive methods for embryo selection
    Sallam, H. N.
    Sallam, N. H.
    Sallam, S. H.
    FACTS VIEWS AND VISION IN OBGYN, 2016, 8 (02) : 87 - 100
  • [29] A review of non-invasive BCI devices
    Veena, N.
    Anitha, N.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2020, 34 (03) : 205 - 233
  • [30] Non-invasive vital signal monitoring
    Wang Zenan
    Chee, Jonny
    Poo, Chua Kok
    Chen ZhouDe
    SOUTHEAST ASIAN INTERNATIONAL ADVANCES IN MICRO/NANOTECHNOLOGY, 2010, 7743