Measurement of U and Pu isotope ratios in hair and nail samples using extraction chromatography and multi-collector inductively coupled plasma mass spectrometry

被引:9
|
作者
Brown, J. N. W. [1 ]
Robertson, J. D. [1 ,2 ]
Brockman, J. D. [2 ]
机构
[1] Univ Missouri, Dept Chem, Columbia, MO 65211 USA
[2] Univ Missouri, Res Reactor, Columbia, MO 65211 USA
基金
美国国家科学基金会;
关键词
Biomonitor; Nuclear forensics; Actinide; Uranium; Plutonium; MC-ICPMS; Extraction chromatography; DRINKING-WATER; ENVIRONMENTAL-SAMPLES; ICP-MS; URANIUM; URINE; PLUTONIUM; SYSTEMATICS; INGESTION;
D O I
10.1016/j.talanta.2014.06.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A bioassay capable of monitoring occupational or environmental exposure to special nuclear materials would be a useful tool for nuclear nonproliferation programs. Hair and nail are potential biomonitors of exposure to U and Pu. A method is described to measure isotope ratios of ultra-trace concentrations of U and Pu in hair and nail samples. The method uses multiple extraction chromatography resins to separate U and Pu fractions from the sample matrix. The U recovery was quantitative while the Pu recovery ranged from 81% to 109%, with a U decontamination factor of 5 x 10(4). Following the separation U-234/U-238, U-235/U-238 and Pu-240/Pu-239 were measured in human hair and hair and nail samples using multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS). The human hair and nail samples had elevated ratios of U-234/U-238 which could reflect exposure to naturally fractionated U. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:481 / 485
页数:5
相关论文
共 50 条
  • [41] Determination of Eu isotopic ratio by multi-collector inductively coupled plasma mass spectrometry using a Sm internal standard
    Lee, Seung-Gu
    Tanaka, Tsuyoshi
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2019, 156 : 42 - 50
  • [42] Bromine isotope ratio measurements in seawater by multi-collector inductively coupled plasma-mass spectrometry with a conventional sample introduction system
    Jefferson S. de Gois
    Paul Vallelonga
    Andrea Spolaor
    Veerle Devulder
    Daniel L. G. Borges
    Frank Vanhaecke
    Analytical and Bioanalytical Chemistry, 2016, 408 : 409 - 416
  • [43] Comparison of factors affecting the accuracy of high-precision magnesium isotope analysis by multi-collector inductively coupled plasma mass spectrometry
    Teng, Fang-Zhen
    Yang, Wei
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (01) : 19 - 24
  • [44] Non-matrix-matched determination of lead isotope ratios in ancient bronze artifacts by femtosecond laser ablation multi-collector inductively coupled plasma mass spectrometry
    Bao Zhian
    Yuan Wenting
    Yuan Honglin
    Liu Xu
    Chen Kaiyun
    Zong Chunlei
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2016, 402 : 12 - 19
  • [45] Separation of uranium and plutonium isotopes for measurement by multi collector inductively coupled plasma mass spectroscopy
    R. E. Martinelli
    T. F. Hamilton
    R. W. Williams
    S. R. Kehl
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 282 : 343 - 347
  • [46] Separation of uranium and plutonium isotopes for measurement by multi collector inductively coupled plasma mass spectroscopy
    Martinelli, R. E.
    Hamilton, T. F.
    Williams, R. W.
    Kehl, S. R.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (02) : 343 - 347
  • [47] Determination of Uranium and Thorium Isotope Ratios by Inductively Coupled Plasma Mass Spectrometry
    M. G. Demidova
    A. I. Saprykin
    Journal of Analytical Chemistry, 2004, 59 : 45 - 49
  • [48] High-Precision Measurement of Variations in Calcium Isotope Ratios in Urine by Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Morgan, Jennifer L. L.
    Gordon, Gwyneth W.
    Arrua, Ruth C.
    Skulan, Joseph L.
    Anbar, Ariel D.
    Bullen, Thomas D.
    ANALYTICAL CHEMISTRY, 2011, 83 (18) : 6956 - 6962
  • [49] Rapid determination of Pu isotopes for decommission concrete samples by inductively coupled plasma mass spectrometry
    Zhongtang Wang
    Wei Wen
    Wei Quan
    Liang Du
    Ping Wang
    Jinxian Lin
    Yun Xie
    Zhaoyi Tan
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 316 : 411 - 417
  • [50] Determination of 236U/238U and 235U/238U isotope ratios in human urine by inductively coupled plasma mass spectrometry
    Gray, Patrick J.
    Zhang, Lingsu
    Xu, Hanna
    McDiarmid, Melissa
    Squibb, Katherine
    Centeno, Jose A.
    MICROCHEMICAL JOURNAL, 2012, 105 : 94 - 100