Evaluation of reversed phase columns designed for polar compounds and porous graphitic carbon in "trapping" and separating neurotransmitters

被引:36
作者
Thiebaut, Didier [1 ]
Vial, Jerome
Michel, Monika
Hennion, Marie-Claire
Greibrokk, Tyge
机构
[1] ESPCI, Lab Environm & Chim Analyt, CNRS, UMR 7121, F-75005 Paris, France
[2] Univ Oslo, Dept Chem, Analyt Chem Res Grp, N-0315 Oslo, Norway
关键词
neurotransmitters; stationary phases; LC; porous graphitic carbon;
D O I
10.1016/j.chroma.2006.04.074
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantification of neurotransmitters as biologically active analytes in neurological samples is of high interest for studying their effect on multiple targets. This work is part of a strategy involving two-dimensional liquid chromatography (2D LC) system with mass spectrometry (MS) detection. The concept of the on-line LC system is the coupling of reversed phase liquid chromatography (R-PLC, the second separation dimension) to ion-exchange chromatography (IEC, the first dimension). Our objective in this study is to find the appropriate second dimension column, ensuring that samples of neurotransmitters are refocused and separated on it. Silica-based columns designed specifically to retain polar compounds were tested in LC conditions and compared with results obtained with a porous graphitic carbon (PGC, Hypercarb) column. These polar embedded, polar endcapped. and high-density alkyl chain columns successfully separated analytes in question using mobile phase systems with high percentage of water, or even pure water. Only Hypercarb column provided efficient retention of the most polar neurotransmitters and could be used for trapping and preconcentrating the compounds without rapid breakthrough. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 46 条
[1]   Isolation of the components of a complex mixture by means of column switching for their enhanced detection by mass spectrometry [J].
Allen, JR ;
Williams, JD ;
Burinsky, DJ ;
Cole, SR .
JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) :209-219
[2]   Catecholamines and methods for their identification and quantitation in biological tissues and fluids [J].
Bergquist, J ;
Sciubisz, A ;
Kaczor, A ;
Silberring, J .
JOURNAL OF NEUROSCIENCE METHODS, 2002, 113 (01) :1-13
[3]   Determination of isoprostanes in urine samples from Alzheimer patients using porous graphitic carbon liquid chromatography-tandem mass spectrometry [J].
Bohnstedt, KC ;
Karlberg, B ;
Wahlund, LO ;
Jönhagen, ME ;
Basun, H ;
Schmidt, S .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (01) :11-19
[4]   Short term storage of samples containing monoamines: ascorbic acid and glutathione give better protection against degradation than perchloric acid [J].
Boix, F ;
Woien, G ;
Sagvolden, T .
JOURNAL OF NEUROSCIENCE METHODS, 1997, 75 (01) :69-73
[5]   Ion-pair chromatography on a porous graphitic carbon stationary phase for the analysis of twenty underivatized protein amino acids [J].
Chaimbault, P ;
Petritis, K ;
Elfakir, C ;
Dreux, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) :245-254
[6]   Evaluation of degradation of urinary catecholamines and metanephrines and deconjugation of their sulfoconjugates using stability-indicating reversed-phase ion-pair HPLC with electrochemical detection [J].
Chan, ECY ;
Wee, PY ;
Ho, PC .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (03) :515-526
[7]  
Daali Y, 2002, J SEP SCI, V25, P280, DOI 10.1002/1615-9314(20020401)25:5/6&lt
[8]  
280::AID-
[9]   STATISTICAL-METHOD FOR ESTIMATION OF NUMBER OF COMPONENTS FROM SINGLE COMPLEX CHROMATOGRAMS - APPLICATION TO EXPERIMENTAL CHROMATOGRAMS [J].
DAVIS, JM ;
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2178-2182
[10]   STATISTICAL-METHOD FOR ESTIMATION OF NUMBER OF COMPONENTS FROM SINGLE COMPLEX CHROMATOGRAMS - THEORY, COMPUTER-BASED TESTING, AND ANALYSIS OF ERRORS [J].
DAVIS, JM ;
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2168-2177