AN INTEGRATED OUTSIDE AIR CONTROL OF AIR HANDLING UNITS IN OFFICE BUILDINGS FOR ENERGY EFFICIENCY

被引:0
|
作者
Yu, Y. B. [1 ]
Liu, M. S. [2 ]
Yu, D. H. [2 ]
Loftness, V. [1 ]
机构
[1] Carnegie Mellon Univ, Ctr Bldg Performance & Diagnost, Pittsburgh, PA 15213 USA
[2] Univ Nebraska, Dept Architectural Engn, Omaha, NE 68172 USA
来源
7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV | 2011年
关键词
Integrated AHU; Continuous Commissioning; Office building; Energy Efficiency; SYSTEM;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An air handling unit (AHU) along with the downstream terminals is considered as the primary independent thermal processing and air distribution system in buildings. However, this AHU oriented practice limits the utilization of heat surplus in building regions and operation difference across the AHUs. To improve the energy efficiency, based on zoned AHU, this paper proposes an integrated outside air (OA) control of AHU in office buildings with open space. The theory is revealed and demonstrated by providing: 1. a mathematic model and deduction of OA constraints for an acceptable indoor air quality (IAQ); 2. an integrated OA schedule of the new AHU operation; 3. an hourly simulation-based performance evaluation. With the technology, about 176,400 kWh theimal energy can be saved annually in the case building. This innovation is easy to implement as an improved control in new, or as a Continuous Commissioning measures in existing office buildings.
引用
收藏
页码:1265 / 1271
页数:7
相关论文
共 50 条
  • [41] Proof of concept system for supporting energy efficiency in office buildings
    Muntean, Ionut
    PROCEEDINGS OF 9TH INTERNATIONAL CONFERENCE ON MODERN POWER SYSTEMS (MPS 2021), 2021,
  • [42] Optimization of the Energy Efficiency of a Piston Compressed Air Engine
    Yu, Qihui
    Cai, Maolin
    Shi, Yan
    Fan, Zichuan
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2014, 60 (06): : 395 - 406
  • [43] Study of the Energy Efficiency of Compressed Air Storage Tanks
    Dindorf, Ryszard
    SUSTAINABILITY, 2024, 16 (04)
  • [44] The Helsinki office environment study: Air change in mechanically ventilated buildings
    Teijonsalo, J
    Jaakkola, JJK
    Seppanen, O
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1996, 6 (02): : 111 - 117
  • [45] Reducing university air handling unit energy usage through controls-based energy efficiency measures
    Shea, Ryan P.
    Kissock, Kelly
    Selvacanabady, Abinesh
    ENERGY AND BUILDINGS, 2019, 194 : 105 - 112
  • [46] Energy Efficiency of Compressed Air Systems
    Mousavi, Smaeil
    Kara, Sami
    Kornfeld, Bernard
    21ST CIRP CONFERENCE ON LIFE CYCLE ENGINEERING, 2014, 15 : 313 - 318
  • [47] Energy performance and thermal comfort of integrated energy recovery ventilator system with air-conditioner for passive buildings
    Cho, Wonhee
    Heo, Juneyeong
    Park, Myeong Hyeon
    Seo, Hyeong Joon
    Lee, Kisup
    Lee, Dong Gyu
    Kim, Yongchan
    ENERGY AND BUILDINGS, 2023, 295
  • [48] Pressurized cryogenic air energy storage for efficiency improvement of liquid air energy storage
    Kim, Juwon
    Chang, Daejun
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 5086 - 5091
  • [49] Energy efficient climate control in office buildings without giving up implementability
    Gruber, Mattias
    Truschel, Anders
    Dalenback, Jan-Olof
    APPLIED ENERGY, 2015, 154 : 934 - 943
  • [50] Air handling unit supply air temperature optimal control during economizer cycles
    Wang, Gang
    Song, Li
    ENERGY AND BUILDINGS, 2012, 49 : 310 - 316