Application of Internal Standard Method for Several 3d-Transition Metallic Elements in Flame Atomic Absorption Spectrometry Using a Multi-wavelength High-resolution Spectrometer

被引:2
作者
Toya, Yusuke [1 ]
Itagaki, Toshiko [1 ]
Wagatsuma, Kazuaki [1 ]
机构
[1] Tohoku Univ, Inst Mat Res, 2-1-1 Katahira, Sendai, Miyagi 9808577, Japan
关键词
Flame atomic absorption spectrometry; internal standard method; continuum radiation source spectrometer; 3d-transition metals; palladium-group elements; HIGH-PURITY IRON; WATER SAMPLES; REDUCTIVE COPRECIPITATION; TRACE AMOUNTS; PRECONCENTRATION; PALLADIUM; STEEL; GOLD;
D O I
10.2116/analsci.33.217
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We investigated a simultaneous internal standard method in flame atomic absorption spectrometry (FAAS), in order to better the analytical precision of 3d-transition metals contained in steel materials. For this purpose, a new spectrometer system for FAAS, comprising a bright xenon lamp as the primary radiation source and a high-resolution Echelle monochromator, was employed to measure several absorption lines at a wavelength width of ca. 0.3 nm at the same time, which enables the absorbances of an analytical line and also an internal standard line to be estimated. In considering several criteria for selecting an internal standard element and the absorption line, it could be suggested that platinum group elements: ruthenium, rhodium, or palladium, were suitable for an internal standard element to determine the 3d-transition metal elements, such as titanium, iron, and nickel, by measuring an appropriate pair of these absorption lines simultaneously. Several variances of the absorption signal, such as a variation in aspirated amounts of sample solution and a short-period drift of the primary light source, would be corrected and thus reduced, when the absorbance ratio of the analytical line to the internal standard line was measured. In Ti-Pd, Ni-Rh, and Fe-Ru systems chosen as typical test samples, the repeatability of the signal respnses was investigated with/without the internal standard method, resulting in better precision when the internal standard method was applied in the FAAS with a nitrous oxide-acetylene flame rather than an air-acetylene flame.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 22 条
[1]  
Analytik Jena Corp, 2013, OP MAN CONTR AA 700
[2]  
[Anonymous], 1994, ISO5725
[3]  
[Anonymous], 2013, G125709 JIS JAP STAN
[4]  
[Anonymous], 1998, ISO5725
[5]   DETERMINATION OF TRACE AMOUNTS OF SELENIUM AND TELLURIUM IN HIGH-PURITY IRON BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY AFTER REDUCTIVE COPRECIPITATION WITH PALLADIUM USING ASCORBIC-ACID [J].
ASHINO, T ;
TAKADA, K ;
HIROKAWA, K .
ANALYTICA CHIMICA ACTA, 1994, 297 (03) :443-451
[6]   Determination of trace amounts of antimony, germanium and tin in high-purity iron by electrothermal atomic absorption spectrometry after reductive coprecipitation with palladium [J].
Ashino, T ;
Takada, K .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (08) :577-583
[7]  
Barin I., 1995, THERMOCHEMICAL DATA, V1, DOI DOI 10.1002/9783527619825
[8]  
Broekaert J. A., 2002, ANAL ATOMIC SPECTROM
[9]  
da Silva JBB, 1999, ANALYST, V124, P1249
[10]   Simultaneous cloud-point extraction of nine cations from water samples and their determination by flame atomic absorption spectrometry [J].
Farajzadeh, MA ;
Fallahi, MR .
ANALYTICAL SCIENCES, 2006, 22 (04) :635-639