Active ROCOF Relay for Islanding Detection

被引:140
作者
Gupta, Pankaj [1 ]
Bhatia, R. S. [2 ]
Jain, D. K. [3 ]
机构
[1] Indira Gandhi Delhi Tech Univ Women, Dept Elect & Commun Engn, Delhi 110006, India
[2] Natl Inst Technol, Dept Elect Engn, Kurukshetra 136119, Haryana, India
[3] Deenbandhu Chhoturam Univ Sci & Technol, Dept Elect Engn, Murthal 131039, Haryana, India
关键词
Active distribution system (ADS); distributed generation (DG); islanding detection techniques (IDT); loss of mains (LOM); rate of change of frequency (ROCOF); voltage source converter (VSC); EMBEDDED GENERATION APPLICATIONS; DISTRIBUTED GENERATION; NONDETECTION ZONES; VOLTAGE UNBALANCE; CURRENT INJECTION; PERFORMANCE; PROTECTION; SHIFT; SYSTEMS;
D O I
10.1109/TPWRD.2016.2540723
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Intentional frequency perturbation by recently researched active islanding detection techniques for inverter based distributed generation (DG) define new threshold settings for the frequency relays. This innovation has enabled the modern frequency relays to operate inside the non-detection zone (NDZ) of the conventional frequency relays. However, the effect of such perturbation on the performance of the rate of change of frequency (ROCOF) relays has not been researched so far. This paper evaluates the performance of ROCOF relays under such perturbations for an inverter interfaced DG and proposes an algorithm along with the new threshold settings to enable it work under the NDZ. The proposed algorithm is able to differentiate between an islanding and a non-islanding event. The operating principle of relay is based on low frequency current injection through grid side voltage source converter (VSC) control of doubly fed induction generator (DFIG) and therefore, the relay is defined as "active ROCOF relay". Simulations are done in MATLAB.
引用
收藏
页码:420 / 429
页数:10
相关论文
共 38 条
[1]   Performance of ROCOF relays for embedded generation applications [J].
Affonso, CM ;
Freitas, W ;
Xu, W ;
da Silva, LCP .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2005, 152 (01) :109-114
[2]   A review of the islanding detection methods in grid-connected PV inverters [J].
Ahmad, Ku Nurul Edhura Ku ;
Selvaraj, Jeyraj ;
Abd Rahim, Nasrudin .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 21 :756-766
[3]  
[Anonymous], 2005, 15471 IEEE
[4]  
[Anonymous], P INT C EXH EL DISTR
[5]  
Bohan D. Liu, 2011, IEEE POW EN SOC GEN, P1
[6]  
Bower W., 2002, Evaluation of islanding detection methods for utility-interactive inverters in photovoltaic systems
[7]   TRANSFER-TRIP RELAYING OVER A DIGITALLY MULTIPLEXES FIBER OPTIC LINK [J].
BRATTON, RE .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (02) :403-406
[8]  
Etxegarai A., 2011, International Conference on Renewable Energies and Power Quality, ICREPQ, P13
[9]   Comparative analysis between ROCOF and vector surge relays for distributed generation applications [J].
Freitas, W ;
Xu, WS ;
Affonso, CM ;
Huang, ZY .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) :1315-1324
[10]  
Geidl M., 2005, Protection of power systems with distributed generation: state of the art