Radiation eye dose to medical staff during respiratory endoscopy under X-ray fluoroscopy

被引:32
作者
Haga, Yoshihiro [1 ,2 ]
Chida, Koichi [1 ,3 ]
Kimura, Yuichiro [4 ]
Yamanda, Shinsuke [4 ]
Sota, Masahiro [1 ,2 ]
Abe, Mitsuya [2 ]
Kaga, Yuji [2 ]
Meguro, Taiichiro [5 ]
Zuguchi, Masayuki [1 ]
机构
[1] Tohoku Univ, Dept Radiol Technol, Grad Sch Med, Aoba Ku, 2-1 Seiryo, Sendai, Miyagi 9808575, Japan
[2] Sendai Kousei Hosp, Dept Radiol, Aoba Ku, Hirosemachi 4-15, Sendai, Miyagi 9800873, Japan
[3] Tohoku Univ, Int Res Inst Disaster Sci, Div Disaster Med, 6-6-4 Aoba, Sendai, Miyagi 9808579, Japan
[4] Sendai Kousei Hosp, Dept Resp Med, Aoba Ku, Hirosemachi 4-15, Sendai, Miyagi 9800873, Japan
[5] Sendai Kousei Hosp, Dept Cardiovasc Med, Aoba Ku, Hirosemachi 4-15, Sendai, Miyagi 9800873, Japan
关键词
radiation safety eye lens dose; x-ray fluoroscopy; fluoroscopically guided respiratory endoscopy (bronchoscopy); dosimeter; radiation disaster medicine; 3-mm dose-equivalent [Hp(3); PROTECTION; BRONCHOSCOPY; PHYSICIANS;
D O I
10.1093/jrr/rraa034
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Although the clinical value of fluoroscopically guided respiratory endoscopy (bronchoscopy) is clear, there have been very few studies on the radiation dose received by staff during fluoroscopically guided bronchoscopy. The International Commission on Radiological Protection (ICRP) is suggesting reducing the occupational lens dose limit markedly from 150 to 20 mSv/year, averaged over defined periods of five years. The purpose of this study was to clarify the current occupational eye dose of bronchoscopy staff conducting fluoroscopically guided procedures. We measured the occupational eye doses (3-mm-dose equivalent, Hp(3)) of bronchoscopy staff (physicians and nurses) over a 6-month period. The eye doses of eight physicians and three nurses were recorded using a direct eye dosimeter, the DOSIRIS. We also estimated eye doses using personal dosimeters worn at the neck. The mean +/- SD radiation eye doses (DOSIRIS) to physicians and nurses were 7.68 +/- 5.27 and 2.41 +/- 1.94 mSv/6 months, respectively. The new lens dose limit, 20 mSv/year, may be exceeded among bronchoscopy staff, especially physicians. The eye dose of bronchoscopy staff (both physicians and nurses) was underestimated when measured using a neck dosimeter. Hence, the occupational eye dose of bronchoscopy staff should be monitored. To reduce the occupational eye dose, we recommend that staff performing fluoroscopically guided bronchoscopy wear Pb glasses. correct evaluation of the lens dose [Hp(3)] using an eye dosimeter such as the DOSIRIS is necessary for bronchoscopy staff.
引用
收藏
页码:691 / 696
页数:6
相关论文
共 33 条
  • [1] [Anonymous], 2017, JAPAN SOC RESP ENDOS
  • [2] [Anonymous], 2011, ICRP STATEMENT TISSU
  • [3] Bronchoscopic practice in Japan: A survey by the Japan Society for Respiratory Endoscopy in 2010
    Asano, Fumihiro
    Aoe, Motoi
    Ohsaki, Yoshinobu
    Okada, Yoshinori
    Sasada, Shinji
    Sato, Shigeki
    Suzuki, Eiichi
    Senba, Hiroshi
    Fujino, Shozo
    Ohmori, Kazumitsu
    [J]. RESPIROLOGY, 2013, 18 (02) : 284 - 290
  • [4] Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures
    Chida, K
    Saito, H
    Otani, H
    Kohzuki, M
    Takahashi, S
    Yamada, S
    Shirato, K
    Zuguchi, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (03) : 774 - 778
  • [5] Effect of Radiation Monitoring Method and Formula Differences on Estimated Physician Dose during Percutaneous Coronary Intervention
    Chida, K.
    Morishima, Y.
    Masuyama, H.
    Chiba, H.
    Katahira, Y.
    Inaba, Y.
    Mori, I.
    Maruoka, S.
    Takahashi, S.
    Kohzuki, M.
    Zuguchi, M.
    [J]. ACTA RADIOLOGICA, 2009, 50 (02) : 170 - 173
  • [6] Occupational Dose in Interventional Radiology Procedures
    Chida, Koichi
    Kaga, Yuji
    Haga, Yoshihiro
    Kataoka, Nozomi
    Kumasaka, Eriko
    Meguro, Taiichiro
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (01) : 138 - 141
  • [7] Clarifying and Visualizing Sources of Staff-Received Scattered Radiation in Interventional Procedures
    Chida, Koichi
    Takahashi, Takeshi
    Ito, Daisuke
    Shimura, Hirotaka
    Takeda, Ken
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (05) : W900 - W903
  • [8] Radiation Dose to the Pediatric Cardiac Catheterization and Intervention Patient
    Chida, Koichi
    Ohno, Tadayuki
    Kakizaki, Shuhei
    Takegawa, Mika
    Yuuki, Hiroko
    Nakada, Mitsuru
    Takahashi, Shoki
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1175 - 1179
  • [9] Radiation Dose and Radiation Protection for Patients and Physicians During Interventional Procedure
    Chida, Koichi
    Kato, Mamoru
    Kagaya, Yutaka
    Zuguchi, Masayuki
    Saito, Haruo
    Ishibashi, Tadashi
    Takahashi, Shoki
    Yamada, Shogo
    Takai, Yoshihiro
    [J]. JOURNAL OF RADIATION RESEARCH, 2010, 51 (02) : 97 - 105
  • [10] Radiation Dose of Interventional Radiology System Using a Flat-Panel Detector
    Chida, Koichi
    Inaba, Yohei
    Saito, Haruo
    Ishibashi, Tadashi
    Takahashi, Shoki
    Kohzuki, Masahiro
    Zuguchi, Masayuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : 1680 - 1685