Injectable Tissue-Engineered Cartilage Using Commercially Available Fibrin Glue

被引:19
作者
Cakmak, Ozcan [1 ]
Babakurban, Seda T. [9 ]
Akkuzu, Hatice G. [3 ]
Bilgi, Selcuk [2 ]
Ovali, Ercument [4 ,5 ]
Kongur, Merve [4 ,5 ]
Altintas, Hande [6 ]
Yilmaz, Bayram [8 ]
Bilezikci, Banu [10 ]
Celik, Zerrin Y. [11 ]
Yakicier, Mustafa C. [7 ]
Sahin, Feride I. [11 ]
机构
[1] Acibadem Univ, Fac Med, Dept Otolaryngol, Ankara, Turkey
[2] Acibadem Univ, Fac Med, Dept Pathol, Ankara, Turkey
[3] Acibadem Healthcare Grp, Atasehir Surg Med Ctr, Dept Otolaryngol, Ankara, Turkey
[4] Acibadem Healthcare Grp, Labcell Stem Cell Lab, Ankara, Turkey
[5] Acibadem Healthcare Grp, Umbil Cord Blood Bank, Ankara, Turkey
[6] Acibadem Healthcare Grp, Kadikoy Hosp, Dept Otolaryngol, Ankara, Turkey
[7] Acibadem Univ, Fac Med, Dept Med Biol, Ankara, Turkey
[8] Yeditepe Univ, Fac Med, Dept Physiol, Ankara, Turkey
[9] Baskent Univ, Fac Med, Dept Otolaryngol, TR-06490 Ankara, Turkey
[10] Baskent Univ, Fac Med, Dept Pathol, TR-06490 Ankara, Turkey
[11] Baskent Univ, Fac Med Genet, TR-06490 Ankara, Turkey
关键词
Issue engineering; cartilage; fibrin glue; immunocompromised; CHONDROCYTES;
D O I
10.1002/lary.24156
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/HypothesisTo achieve injectable tissue-engineered cartilage using a commercially available fibrin sealant, and to determine the most suitable fibrin glue concentration, cartilage source, and cultured chondrocyte concentration. Study DesignAnimal research. MethodsA total of 28 immuncompetent New Zealand white rabbits were divided into four groups. The cultured chondrocytes from different anatomical sources carried in fibrin glue with and without aprotinin in different concentrations of fibrinogen and thrombin (Tisseell), were injected into forehead and interocular regions of the rabbits. The new tissue formation was harvested at 8 weeks and analyzed through gross and histological analysis. ResultsThe new tissue formations were found in round, elliptical, and flat forms. The mean value of Tisseell and cell suspension was 0.8 cc in all of the rabbits' injection regions, but the mean volume of the samples in which immature cartilage matrix and mature cartilage was 0.1 cc. In the 20 of the 55 injection regions of rabbits (36, 36%), mature and/or immature cartilage formation were observed. We observed inflammatory reactions, abscess formation, and foreign body reactions around the new cartilage tissue of tissue-engineered cartilage. The comparison of results using different cartilage sources, chondrocyte concentrations, or different fibrin glue concentrations did not show any significant difference. ConclusionsWe observed that changing the concentrations of ingredients of commercially available fibrin glue, the source of the cartilage, or the cultured chondrocyte concentration did not have significant effect on neocartilage formation. Level of EvidenceN/A. Laryngoscope, 123:2986-2992, 2013
引用
收藏
页码:2986 / 2992
页数:7
相关论文
共 18 条
  • [11] A biomechanical analysis of an engineered cell-scaffold implant for cartilage repair
    Peretti, GM
    Randolph, MA
    Zaporojan, V
    Bonassar, LJ
    Xu, JW
    Fellers, JC
    Yaremchuk, MJ
    [J]. ANNALS OF PLASTIC SURGERY, 2001, 46 (05) : 533 - 537
  • [12] DESIGN OF NASOSEPTAL CARTILAGE REPLACEMENTS SYNTHESIZED FROM BIODEGRADABLE POLYMERS AND CHONDROCYTES
    PUELACHER, WC
    MOONEY, D
    LANGER, R
    UPTON, J
    VACANTI, JP
    VACANTI, CA
    [J]. BIOMATERIALS, 1994, 15 (10) : 774 - 778
  • [13] Analysis of bending behavior of native and engineered auricular and costal cartilage
    Roy, R
    Kohles, SS
    Zaporojan, V
    Peretti, GM
    Randolph, MA
    Xu, JW
    Bonassar, LJ
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 68A (04) : 597 - 602
  • [14] Injectable tissue-engineered cartilage using a fibrin glue polymer
    Silverman, RP
    Passaretti, D
    Huang, W
    Randolph, MA
    Yaremchuk, M
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 103 (07) : 1809 - 1818
  • [15] Injectable cartilage using polyethylene oxide polymer substrates
    Sims, CD
    Butler, PEM
    Casanova, R
    Lee, BT
    Randolph, MA
    Lee, WPA
    Vacanti, CA
    Yaremchuk, MJ
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 98 (05) : 843 - 850
  • [16] Tissue engineered neocartilage using plasma derived polymer substrates and chondrocytes
    Sims, CD
    Butler, PEM
    Cao, YL
    Casanova, R
    Randolph, MA
    Black, A
    Vacanti, CA
    Yaremchuk, MJ
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 101 (06) : 1580 - 1585
  • [17] Validating the subcutaneous model of injectable autologous cartilage using a fibrin glue scaffold
    Westreich, R
    Kaufman, M
    Gannon, P
    Lawson, W
    [J]. LARYNGOSCOPE, 2004, 114 (12) : 2154 - 2160
  • [18] Injectable tissue-engineered cartilage with different chondrocyte sources
    Xu, JW
    Zaporojan, V
    Peretti, GM
    Roses, RE
    Morse, KB
    Roy, AK
    Mesa, JM
    Randolph, MA
    Bonassar, LJ
    Yaremchuk, MJ
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2004, 113 (05) : 1361 - 1371