A rapid method for the determination of perfluoroalkyl substances including structural isomers of perfluorooctane sulfonic acid in human serum using 96-well plates and column-switching ultra-high performance liquid chromatography tandem mass spectrometry

被引:56
|
作者
Salihovic, Samira [1 ]
Karrman, Anna [1 ]
Lindstrom, Gunilla [1 ]
Lind, P. Monica [2 ]
Lind, Lars [2 ]
van Bavel, Bert [1 ]
机构
[1] Univ Orebro, MTM Res Ctr, Sch Sci & Technol, SE-70182 Orebro, Sweden
[2] Uppsala Univ, Uppsala, Sweden
基金
瑞典研究理事会;
关键词
Human blood; Perfluoroalkyl substances; Structural isomers; Column-switch; PFOS; PFOA; PERFLUORINATED COMPOUNDS; HUMAN PLASMA; POLYFLUOROALKYL; EXTRACTION; EXPOSURE; TRENDS; WATER; PFOS;
D O I
10.1016/j.chroma.2013.07.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To facilitate high-throughput analysis suitable for large epidemiological studies we developed an automated column-switching ultra-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for determination of perfluorocarboxylic acids (PFCAs; C-5, C-6, C-7, C-8, C-9, C-10, C-11, C-12, and C-13), perfluoroalkyl sulfonic acids (PFSAs; C-4, C-6, C-8, and C-10), perfluorooctane sulfonamide (PFOSA), and five groups of structural perfluorooctane sulfonic acid (PFOS) isomers in human serum or plasma. The analytical procedure involves rapid protein precipitation using 96-well plates followed by an automated sample clean-up using an on-line trap column removing many potentially interfering sample components while through the mobile phase gradient the target analytes are eluted onto the analytical column for further separation and subsequent mass detection. The method was linear (R-2 <0.995) at concentrations ranging from 0.01 to 60 ng mL(-1) with method detection limits ranging between 0.01 and 0.17 ng mL(-1) depending on the analyte. The developed method was precise, with repeatability (n = 7) and reproducibility (n =103) coefficients of variation between 2% and 20% for most compounds including PFOS (2% and 8%) and its structural isomers (2-6% and 4-8%). The method was in conformity with a standard reference material. The column-switching HPLC-MS/MS method has been successfully applied for the determination of perfluoroalkyl substances including structural PFOS isomers in human plasma from an epidemiological study. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:164 / 170
页数:7
相关论文
共 29 条
  • [21] Determination of multiple antibiotics in agricultural soil using a quick, easy, cheap, effective, rugged, and safe method coupled with ultra-high performance liquid chromatography-tandem mass spectrometry
    Zhang, Yue
    Li, Yang
    Liu, Xiaoxia
    Sun, Ying
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (02) : 602 - 613
  • [22] Stable isotope dilution ultra-high performance liquid chromatography-tandem mass spectrometry quantitative profiling of tryptophan-related neuroactive substances in human serum and cerebrospinal fluid
    Henykova, Eva
    Vranova, Hana Prikrylova
    Amakorova, Petra
    Pospisil, Tomas
    Zukauskaite, Asta
    Vlckova, Magdalena
    Urbanek, Lubor
    Novak, Ondrej
    Mares, Jan
    Kanovsky, Petr
    Strnad, Miroslav
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1437 : 145 - 157
  • [23] Development of a Highly Sensitive Methodology for Quantitative Determination of Fexofenadine in a Microdose Study by Multiple Injection Method Using Ultra-High Performance Liquid Chromatography with Tandem Mass Spectrometry
    Tanaka, Yukari
    Yoshikawa, Yutaka
    Yasui, Hiroyuki
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2012, 35 (05) : 698 - 704
  • [24] Accurate quantification of mercapturic acids of styrene (PHEMAs) in human urine with direct sample injection using automated column-switching high-performance liquid chromatography coupled with tandem mass spectrometry
    Reska, M.
    Ochsmann, E.
    Kraus, T.
    Schettgen, T.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (08) : 3563 - 3574
  • [25] Validation and application of a high-performance liquid chromatography-tandem mass spectrometric method for simultaneous quantification of lopinavir and ritonavir in human plasma using semi-automated 96-well liquid-liquid extraction
    Wang, Perry G.
    Wei, Jack S.
    Kim, Grace
    Chang, Min
    EI-Shourbagy, Tawakol
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1130 (02) : 302 - 307
  • [26] Rapid Determination of Perfluoroalkyl and Polyfluoroalkyl Substances (PFASs) in Vegetables by on-Line Solid-Phase Extraction (SPE) with Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry (UHPLC-MS/MS)
    Li, Nankun
    Song, Xiaocong
    Shen, Peng
    Zhao, Ci
    ANALYTICAL LETTERS, 2022, 55 (14) : 2227 - 2238
  • [27] Determination of Ionic and Nonionic Perfluoroalkyl Substances (PFASs) in the Surface Water of the Qiantang River, China by Solid-Phase Extraction (SPE) and Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry (UHPLC-MS/MS)
    Jin, Quan
    Liu, Shaoying
    Huang, Xihui
    Ren, Ren
    Zhu, Guonian
    ANALYTICAL LETTERS, 2021, 54 (05) : 802 - 816
  • [28] Development of a Rapid and Simultaneous Detection Method for Buprenorphine, Norbuprenorphine and Naloxone in Human Plasma Using Ultra-high Performance Liquid Chromatography-tandem Mass Spectrometer with Solid-phase Extraction
    Guo Qiaozhen
    Du Zhenxia
    CHINESE JOURNAL OF CHEMISTRY, 2011, 29 (09) : 1922 - 1926
  • [29] Highly sensitive analytical method for the accurate determination of 5-methyltetrahydrofolic acid monoglutamate in various volumes of human plasma using isotope dilution ultra-high performance liquid chromatography-mass spectrometry
    Hyung, Seok-Won
    Lee, Sunyoung
    Han, Jeesoo
    Lee, Joonhee
    Beak, Song-Yee
    Kim, Byungjoo
    Choi, Kiwhan
    Ahn, Seonghee
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1179